Calibrating Independent Component Analysis with Laplacian Reference for Real-Time EEG Artifact Removal

被引:0
|
作者
Abbass, Hussein A. [1 ]
机构
[1] Univ New S Wales, Sch Engn & Informat Technol, ADFA, Canberra, ACT 2600, Australia
来源
NEURAL INFORMATION PROCESSING, ICONIP 2014, PT III | 2014年 / 8836卷
关键词
Electroencephalography; Independent Component Analysis; EEG Preprocessing;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Independent Component Analysis (ICA) has emerged as a necessary preprocessing step when analyzing Electroencephalographic (EEG) data. While many studies reported on the use of ICA for EEG, most of these studies rely on visual inspection of the signal to detect those components that need to be removed from the signal. Little has been done on how to process EEG data in real-time, autonomously, and independent of a human expert inspecting the data. A few attempts have been made in the literature to design standard procedures on the processing of EEG data in real-time environments. To enable standardization to occur, the work and discussion of this paper focus on understanding the impact of different preprocessing steps on the performance of ICA. A proposed cut-off threshold for ICA is demonstrated to produce reliable and sound processing when compared to a Laplacian reference system. A methodology for real-time processing that is simple and efficient is being suggested.
引用
收藏
页码:68 / 75
页数:8
相关论文
共 50 条
  • [1] The Removal of Blink and Saccade Artifact in EEG recordings by Independent Component Analysis
    Dong, Jie
    Wang, Tao
    Zhang, Ai-tao
    Dai, Hong-ya
    2010 3RD INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2010), VOLS 1-7, 2010, : 1071 - 1075
  • [2] Real-time removal of ocular artifacts from EEG based on independent component analysis and manifold learning
    Junfeng Gao
    Pan Lin
    Yong Yang
    Pei Wang
    Chongxun Zheng
    Neural Computing and Applications, 2010, 19 : 1217 - 1226
  • [3] Real-time removal of ocular artifacts from EEG based on independent component analysis and manifold learning
    Gao, Junfeng
    Lin, Pan
    Yang, Yong
    Wang, Pei
    Zheng, Chongxun
    NEURAL COMPUTING & APPLICATIONS, 2010, 19 (08) : 1217 - 1226
  • [4] Automatic EEG Artifact Removal by Independent Component Analysis Using Critical EEG Rhythms
    Zachariah, Anusha
    Jai, Jinu
    Titus, Geevarghese
    2013 INTERNATIONAL CONFERENCE ON CONTROL COMMUNICATION AND COMPUTING (ICCC), 2013, : 364 - 367
  • [5] Complete artifact removal for EEG recorded during continuous fMRI using independent component analysis
    Mantini, D.
    Perrucci, M. G.
    Cugini, S.
    Ferretti, A.
    Romani, G. L.
    Del Gratta, C.
    NEUROIMAGE, 2007, 34 (02) : 598 - 607
  • [6] Artifact Removal from EEG Using a Multi-objective Independent Component Analysis Model
    Goh, Sim Kuan
    Abbass, Hussein A.
    Tan, Kay Chen
    Al Mamun, Abdullah
    NEURAL INFORMATION PROCESSING (ICONIP 2014), PT I, 2014, 8834 : 570 - 577
  • [7] Muscle artifact removal from human sleep EEG by using independent component analysis
    Crespo-Garcia, Maite
    Atienza, Mercedes
    Cantero, Jose L.
    ANNALS OF BIOMEDICAL ENGINEERING, 2008, 36 (03) : 467 - 475
  • [8] Muscle Artifact Removal from Human Sleep EEG by Using Independent Component Analysis
    Maite Crespo-Garcia
    Mercedes Atienza
    Jose L. Cantero
    Annals of Biomedical Engineering, 2008, 36 : 467 - 475
  • [9] Evaluation of a head movement artifact removal method for EEG considering real-time prosessing
    Onikura, Kazuki
    Iramina, Keiji
    2015 8TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON), 2015,
  • [10] A robust adaptive denoising framework for real-time artifact removal in scalp EEG measurements
    Kilicarslan, Atilla
    Grossman, Robert G.
    Contreras-Vidal, Jose Luis
    JOURNAL OF NEURAL ENGINEERING, 2016, 13 (02)