Practical performance analysis of an industrial-scale ultrafiltration membrane water treatment plant

被引:29
作者
Chew, Chun Ming [1 ]
Aroua, M. K. [1 ]
Hussain, M. A. [1 ]
Ismail, W. M. Z. Wan [2 ]
机构
[1] Univ Malaya, Fac Engn, Dept Chem Engn, Kuala Lumpur 50603, Malaysia
[2] Air Kelantan Sdn Bhd, Bangunan PMBK, Kota Bahru 15050, Kelantan, Malaysia
关键词
Ultrafiltration; Water treatment; Design; Operation; WOUND UF MEMBRANE; TREATMENT FACILITY; PERMEATE FLOW; HUMIC-ACID; FILTRATION; BACKWASH; RO; FOULANTS; REMOVAL; DESIGN;
D O I
10.1016/j.jtice.2014.09.013
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Common design and operational issues to evaluate the performance of an ultrafiltration (UF) membrane water treatment plant are highlighted with a case study on an industrial-scale drinking water treatment plant located in Malaysia. This treatment plant has been in operation since February 2013 using dead-end polyethersulfone UF membrane filtration system to produce up to 14 million litres a day of drinking water to a small township. Literature solutions are compared with the practised solutions and elucidated with the case study. Gaps between literature solutions which are mainly based on lab-scale research and industry practices are identified. Reducing this gap will have vast implication to improve the design and operation of industrial-scale UF treatment system. (C) 2014 Taiwan Institute of Chemical Engineers. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:132 / 139
页数:8
相关论文
共 38 条
[1]   Current challenges in membrane separation of CO2 from natural gas: A review [J].
Adewole, J. K. ;
Ahmad, A. L. ;
Ismail, S. ;
Leo, C. P. .
INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2013, 17 :46-65
[2]   Identification of foulants, fouling mechanisms and cleaning efficiency for NF and RO treatment of produced water [J].
Alzahrani, Salem ;
Mohammad, Abdul Wahab ;
Hilal, Nidal ;
Abdullah, Pauzi ;
Jaafar, Othman .
SEPARATION AND PURIFICATION TECHNOLOGY, 2013, 118 :324-341
[3]   Impact of chemical cleaning on properties and functioning of polyethersulfone membranes [J].
Arkhangelsky, Elizabeth ;
Kuzmenko, Denis ;
Gitis, Vitaly .
JOURNAL OF MEMBRANE SCIENCE, 2007, 305 (1-2) :176-184
[4]   Organic fouling and floc transport in capillaries [J].
Arkhangelsky, Elizabeth ;
Lerch, Andre ;
Uhl, Wolfgang ;
Gitis, Vitaly .
SEPARATION AND PURIFICATION TECHNOLOGY, 2011, 80 (03) :482-489
[5]   AQUAPOT: Study of the causes in reduction of permeate flow in spiral wound UF membrane. Simulation of a non-rigorous cleaning protocol in a drinkable water treatment facility [J].
Arnal, J. M. ;
Garcia-Fayos, B. ;
Verdu, G. ;
Lora, J. ;
Sancho, A. .
DESALINATION, 2008, 222 (1-3) :513-518
[6]   AQUAPOT:: study of several cleaning solutions to recover permeate flow in a humanitarian drinking water treatment facility based on spiral wound UF membrane.: Preliminary test (I) [J].
Arnal, J. M. ;
Garcia-Fayos, B. ;
Lora, J. ;
Verdu, G. ;
Sancho, M. .
DESALINATION, 2008, 221 (1-3) :331-337
[7]   Membrane fouling during ultrafiltration (UF) of surface water: Effects of sludge discharge interval (SDI) [J].
Bai, Langming ;
Qu, Fangshu ;
Liang, Heng ;
Ma, Jun ;
Chang, Haiqing ;
Wang, Meilian ;
Li, Guibai .
DESALINATION, 2013, 319 :18-24
[8]   Coupling air-assisted backwash and rinsing steps: a new way to improve ultrafiltration process operation for inside-out hollow fibre modules [J].
Bessiere, Y. ;
Guigui, C. ;
Remize, P. J. ;
Cabassud, C. .
DESALINATION, 2009, 240 (1-3) :71-77
[9]   The MFI-UF as a water quality test and monitor [J].
Boerlage, SFE ;
Kennedy, MD ;
Aniye, MP ;
Abogrean, E ;
Tarawneh, ZS ;
Schippers, JC .
JOURNAL OF MEMBRANE SCIENCE, 2003, 211 (02) :271-289
[10]   Pilot tests of Multibore UF membrane at Addur SWRO Desalination Plant, Bahrain [J].
Bu-Rashid, Khalid Ahmed ;
Czolkoss, Wolfgang .
DESALINATION, 2007, 203 (1-3) :229-242