Extraordinary enhancement of a 5-fluorouracil electrode by praepagen HY micellar solutions

被引:11
作者
Abu Shawish, Hazem M. [1 ]
Abu Ghalwa, Nasser [2 ]
Al-Kashef, Iyad D. [2 ]
Saadeh, Salman M. [3 ]
Almonem, Khalid I. Abed [4 ]
机构
[1] Al Aqsa Univ, Dept Chem, Coll Sci, Gaza, Palestine
[2] Al Azhar Univ, Dept Chem, Gaza, Palestine
[3] Islamic Univ Gaza, Dept Chem, Gaza, Palestine
[4] Univ Coll Appl Sci, Hlth Profess, Gaza, Palestine
关键词
Surfactants; Carbon paste electrodes; 5-Flourouracil; Anticancer drug; Potentiometry; ION-SELECTIVE ELECTRODES; ANTICANCER DRUG 5-FLUOROURACIL; CARBON-PASTE ELECTRODE; LC-MS/MS METHOD; ELECTROCHEMICAL-BEHAVIOR; HUMAN PLASMA; TEMPERATURE; UV; METABOLITE; TOXICITY;
D O I
10.1016/j.microc.2019.104316
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Being able to incorporate 16 drug molecules in a micelle, alkyl hydroxyethyl dimethyl ammonium chloride (Praepagen HY), a surfactant, showed a distinct improvement in the performance of electrodes for determination of the anticancer 5-flourouracil (abbreviated FU). Praepagen HY can bring in this number of drug molecules into action where they are needed. This was attained by dissolving the samples in a praepagen HY utilizing a few carbon paste electrodes comprising derivatives of FU, namely FU-DAP, FU-DUL and FU-VAR designated S-1, S-2 and S-3 respectively. Thus, the presently fabricated sensors developed competitive properties which make them strongly attractive for determination of FU especially the first. These electrodes show Nernstian slopes of 31.6 mV, 31.7 mV and 28.6 mV per decade respectively for FU ion over a wide concentration range from 6.3 x 10(-6) to 1.0 x 10(-2), 3.5 x 10(-6) to 1.0 x 10(-2), and 1.2 x 10(-5) to 1.0 x 10(-2) M with notably low detection limits of 3.2 x 10(-6), 1.9 x 10(-6) and 1.1 x 10(-5) M, They show significantly fast response time (ca. 5-10 s). The present sensors show distinct selectivity toward the drug ion in comparison to other common anions. The potentiometric responses are independent of the pH of the test solution in the pH range 4.0-8.0. Practically, these sensors were satisfactorily used as indicators in potentiometric titration with S-1, S-2 and S-3 and determination of the drug ions in pharmaceutical preparations and urine.
引用
收藏
页数:9
相关论文
共 48 条
[11]   LC-MS/MS method for simultaneous analysis of uracil, 5,6-dihydrouracil, 5-fluorouracil and 5-fluoro-5,6-dihydrouracil in human plasma for therapeutic drug monitoring and toxicity prediction in cancer patients [J].
Buechel, Barbara ;
Rhyn, Peter ;
Schuerch, Stefan ;
Buehr, Claudia ;
Amstutz, Ursula ;
Largiader, Carlo R. .
BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (01) :7-16
[12]   Electrochemical behavior of anticancer drug 5-fluorouracil at carbon paste electrode and its analytical application [J].
Bukkitgar, Shikandar D. ;
Shetti, Nagaraj P. .
JOURNAL OF ANALYTICAL SCIENCE AND TECHNOLOGY, 2016, 7
[13]   Electrochemical Sensor for the Determination of Anticancer Drug 5-Fluorouracil at Glucose Modified Electrode [J].
Bukkitgar, Shikandar D. ;
Shetti, Nagaraj P. .
CHEMISTRYSELECT, 2016, 1 (04) :771-777
[14]   Electrochemical behavior of an anticancer drug 5-fluorouracil at methylene blue modified carbon paste electrode [J].
Bukkitgar, Shikandar D. ;
Shetti, Nagaraj P. .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 65 :262-268
[15]  
Bunnell CA, 1998, ONCOLOGY-NY, V12, P39
[16]   Potentiometric polymeric membrane electrodes for measurement of environmental samples at trace levels:: New requirements for selectivities and measuring protocols, and comparison with ICPMS [J].
Ceresa, A ;
Bakker, E ;
Hattendorf, B ;
Günther, D ;
Pretsch, E .
ANALYTICAL CHEMISTRY, 2001, 73 (02) :343-351
[17]   Effect of temperature and additives on the critical micelle concentration and thermodynamics of micelle formation of sodium dodecyl benzene sulfonate and dodecyltrimethylammonium bromide in aqueous solution: A conductometric study [J].
Chauhan, S. ;
Sharma, Kundan .
JOURNAL OF CHEMICAL THERMODYNAMICS, 2014, 71 :205-211
[18]   Temperature dependence of critical micelle concentration of polyoxyethylenated non-ionic surfactants [J].
Chen, LJ ;
Lin, SY ;
Huang, CC ;
Chen, EM .
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 1998, 135 (1-3) :175-181
[19]  
Cojocaru IC, 2012, FARMACIA, V60, P379
[20]   Interaction of hydrochlorothiazide with cationic surfactant micelles of cetyltrimethylammonium bromide [J].
Cudina, O ;
Karljikovic-Rajic, K ;
Ruvarac-Bugarcic, I ;
Jankovic, I .