Extraordinary enhancement of a 5-fluorouracil electrode by praepagen HY micellar solutions

被引:11
作者
Abu Shawish, Hazem M. [1 ]
Abu Ghalwa, Nasser [2 ]
Al-Kashef, Iyad D. [2 ]
Saadeh, Salman M. [3 ]
Almonem, Khalid I. Abed [4 ]
机构
[1] Al Aqsa Univ, Dept Chem, Coll Sci, Gaza, Palestine
[2] Al Azhar Univ, Dept Chem, Gaza, Palestine
[3] Islamic Univ Gaza, Dept Chem, Gaza, Palestine
[4] Univ Coll Appl Sci, Hlth Profess, Gaza, Palestine
关键词
Surfactants; Carbon paste electrodes; 5-Flourouracil; Anticancer drug; Potentiometry; ION-SELECTIVE ELECTRODES; ANTICANCER DRUG 5-FLUOROURACIL; CARBON-PASTE ELECTRODE; LC-MS/MS METHOD; ELECTROCHEMICAL-BEHAVIOR; HUMAN PLASMA; TEMPERATURE; UV; METABOLITE; TOXICITY;
D O I
10.1016/j.microc.2019.104316
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Being able to incorporate 16 drug molecules in a micelle, alkyl hydroxyethyl dimethyl ammonium chloride (Praepagen HY), a surfactant, showed a distinct improvement in the performance of electrodes for determination of the anticancer 5-flourouracil (abbreviated FU). Praepagen HY can bring in this number of drug molecules into action where they are needed. This was attained by dissolving the samples in a praepagen HY utilizing a few carbon paste electrodes comprising derivatives of FU, namely FU-DAP, FU-DUL and FU-VAR designated S-1, S-2 and S-3 respectively. Thus, the presently fabricated sensors developed competitive properties which make them strongly attractive for determination of FU especially the first. These electrodes show Nernstian slopes of 31.6 mV, 31.7 mV and 28.6 mV per decade respectively for FU ion over a wide concentration range from 6.3 x 10(-6) to 1.0 x 10(-2), 3.5 x 10(-6) to 1.0 x 10(-2), and 1.2 x 10(-5) to 1.0 x 10(-2) M with notably low detection limits of 3.2 x 10(-6), 1.9 x 10(-6) and 1.1 x 10(-5) M, They show significantly fast response time (ca. 5-10 s). The present sensors show distinct selectivity toward the drug ion in comparison to other common anions. The potentiometric responses are independent of the pH of the test solution in the pH range 4.0-8.0. Practically, these sensors were satisfactorily used as indicators in potentiometric titration with S-1, S-2 and S-3 and determination of the drug ions in pharmaceutical preparations and urine.
引用
收藏
页数:9
相关论文
共 48 条
[1]   Determination of haloperidol drug in ampoules and in urine samples using a potentiometric modified carbon paste electrode [J].
Abu Shawish, Hazem M. ;
Almonem, Khaled I. Abed ;
Saadeh, Salman M. ;
Al-Iham, Wael S. .
MEASUREMENT, 2016, 78 :180-186
[2]   A comparative study of solid and liquid inner contact benzalkonium chloride ion-selective electrode membranes [J].
Abu Shawish, Hazem M. ;
Khedr, Abdalla M. ;
Abed-Almonem, Khalid I. ;
Gaber, M. .
TALANTA, 2012, 101 :211-219
[3]   Modified carbon paste electrode for potentiometric determination of silver(I) ions in burning cream and radiological films [J].
Abu-Shawish, Hazem M. ;
Saadeh, Salman M. ;
Dalloul, Hany M. ;
Najri, Bassam ;
Al Athamna, Hassan .
SENSORS AND ACTUATORS B-CHEMICAL, 2013, 182 :374-381
[4]   A mercury(II) selective sensor based on N,N′-bis(salicylaldehyde)-phenylenediamine as neutral carrier for potentiometric analysis in water samples [J].
Abu-Shawish, Hazem M. .
JOURNAL OF HAZARDOUS MATERIALS, 2009, 167 (1-3) :602-608
[5]   Validated liquid chromatographic determination of 5-fluorouracil in human plasma [J].
Alsarra, IA ;
Alarifi, MN .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 804 (02) :435-439
[6]   GAS-CHROMATOGRAPHIC MASS-SPECTROMETRIC METHOD FOR ROUTINE MONITORING OF 5-FLUOROURACIL IN PLASMA OF PATIENTS RECEIVING LOW-LEVEL PROTRACTED INFUSIONS [J].
ANDERSON, LW ;
PARKER, RJ ;
COLLINS, JM ;
AHLGREN, JD ;
WILKINSON, D ;
STRONG, JM .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 581 (02) :195-201
[7]   Selectivity of potentiometric ion sensors [J].
Bakker, E ;
Pretsch, E ;
Bühlmann, P .
ANALYTICAL CHEMISTRY, 2000, 72 (06) :1127-1133
[8]  
BERNADOU J, 1985, CLIN CHEM, V31, P846
[9]   Gemcitabine/cisplatin versus 5-fluorouracil/mitomycin C chemoradiotherapy in locally advanced pancreatic cancer: a retrospective analysis of 93 patients [J].
Brunner, Thomas B. ;
Sauer, Rolf ;
Fietkau, Rainer .
RADIATION ONCOLOGY, 2011, 6
[10]   RECOMMENDATIONS FOR NOMENCLATURE OF ION-SELECTIVE ELECTRODES - (IUPAC RECOMMENDATIONS 1994) [J].
BUCK, RP ;
LINDNER, E .
PURE AND APPLIED CHEMISTRY, 1994, 66 (12) :2527-2536