TWENTE Study: The Real-World Endeavor Resolute Versus Xience V Drug-Eluting Stent Study in Twente: study design, rationale and objectives

被引:12
作者
Basalus, M. W. Z. [1 ]
Tandjung, K. [1 ]
van Houwelingen, K. G. [1 ]
Stoel, M. G. [1 ]
de Man, F. H. A. F. [1 ]
Louwerenburg, J. W. [1 ]
Said, S. A. M. [3 ]
Linssen, G. C. M. [4 ]
Kleijne, M. A. W. J. [5 ]
van der Palen, J. [6 ,7 ]
Huisman, J. [1 ]
Verhorst, P. M. J. [1 ]
von Birgelen, C. [1 ,2 ]
机构
[1] Medisch Spectrum Twente, Dept Cardiol, Thoraxctr Twente, NL-7500 KA Enschede, Netherlands
[2] Univ Twente, MIRA, Inst Biomed Technol & Tech Med, NL-7500 AE Enschede, Netherlands
[3] Hosp Grp Twente, Dept Cardiol, Hengelo, Netherlands
[4] Hosp Grp Twente, Dept Cardiol, Almelo, Netherlands
[5] Streekziekenhuis Koningin Beatrix, Dept Cardiol, Winterswijk, Netherlands
[6] Medisch Spectrum Twente, Dept Epidemiol, NL-7500 KA Enschede, Netherlands
[7] Univ Twente, Dept Res Methodol Measurement & Data Anal, NL-7500 AE Enschede, Netherlands
关键词
Drug-Eluting Stents; Coronary Artery Diseases; Angioplasty; Transluminal; Percutaneous Coronary; Thrombosis; Randomized Controlled Trial; CORONARY-ARTERY-DISEASE; BARE-METAL STENTS; CLINICAL FOLLOW-UP; RANDOMIZED-TRIAL; INTRAVASCULAR ULTRASOUND; IMPLANTATION; METAANALYSIS; THROMBOSIS; EFFICACY; SYSTEM;
D O I
10.1007/BF03091792
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. New-generation drug-eluting stents (DES) may solve several problems encountered with first-generation DES, but there is a lack of prospective head-to-head comparisons between new-generation DES. In addition, the outcome of regulatory trials may not perfectly reflect the outcome in 'real world' patients. Objectives. To compare the efficacy and safety of two new-generation DES in a 'real world' patient population. Methods. A prospective, randomised, single-blinded clinical trial to evaluate clinical outcome after Endeavor Resolute vs. Xience V stent implantation. The primary endpoint is target vessel failure at one-year follow-up. In addition, the study comprises a two-year and an open-label five-year follow-up. (Neth Heart J 2010;18:360-4.)
引用
收藏
页码:360 / 364
页数:5
相关论文
共 29 条
[1]   Coating irregularities of durable polymer-based drug-eluting stents as assessed by scanning electron microscopy [J].
Basalus, Mounir W. Z. ;
Ankone, Marc J. K. ;
van Houwelingen, K. Gert ;
de Man, Frits H. A. F. ;
von Birgelen, Clemens .
EUROINTERVENTION, 2009, 5 (01) :157-165
[2]  
BASALUS MW, 2010, J INTERV CARDIOL, V2, P159
[3]   Sirolimus-eluting stent implantation in diabetic patients with multivessel coronary artery disease [J].
Briguori, C ;
Colombo, A ;
Airoldi, F ;
Focaccio, A ;
Iakovou, L ;
Chieffo, A ;
Michev, I ;
Montorfano, M ;
Bonizzoni, E ;
Ricciardelli, B ;
Condorelli, G .
AMERICAN HEART JOURNAL, 2005, 150 (04) :807-813
[4]   Experimental efficacy of an everolimus eluting cobalt chromium stent [J].
Carter, AJ ;
Brodeur, A ;
Collingwood, R ;
Ross, S ;
Gibson, L ;
Wang, CA ;
Haller, S ;
Coleman, L ;
Virmani, R .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2006, 68 (01) :97-103
[5]   Clinical end points in coronary stent trials - A case for standardized definitions [J].
Cutlip, Donald E. ;
Windecker, Stephan ;
Mehran, Roxana ;
Boam, Ashley ;
Cohen, David J. ;
van Es, Gerrit-Anne ;
Steg, P. Gabriel ;
Morel, Marie-angele ;
Mauri, Laura ;
Vranckx, Pascal ;
McFadden, Eugene ;
Lansky, Alexandra ;
Hamon, Martial ;
Krucoff, Mitchell W. ;
Serruys, Patrick W. .
CIRCULATION, 2007, 115 (17) :2344-2351
[6]   Early and late coronary stent thrombosis of sirolimus-eluting and paclitaxel-eluting stents in routine clinical practice:: data from a large two-institutional cohort study [J].
Daemen, Joost ;
Wenaweser, Peter ;
Tsuchida, Keiichi ;
Abrecht, Linda ;
Sophia, Vaina ;
Morger, Cyrill ;
Kukreja, Neville ;
Jueni, Peter ;
Sianos, Georgios ;
Hellige, Gerrit ;
van Domburg, Ron T. ;
Hess, Otto M. ;
Boersma, Eric ;
Meier, Bernhard ;
Windecker, Stephan ;
Serruys, Patrick W. .
LANCET, 2007, 369 (9562) :667-678
[7]   Maintenance of long-term clinical benefit with sirolimus-eluting coronary stents -: Three-year results of the RAVEL trial [J].
Fajadet, J ;
Morice, MC ;
Bode, C ;
Barragan, P ;
Serruys, PW ;
Wijns, W ;
Constantini, CR ;
Guermonprez, JL ;
Eltchaninoff, H ;
Blanchard, D ;
Bartorelli, A ;
Laarman, GJ ;
Perin, MA ;
Sousa, JE ;
Schuler, G ;
Molnar, F ;
Guagliumi, G ;
Colombo, A ;
Hayashi, EB ;
Wülfert, E .
CIRCULATION, 2005, 111 (08) :1040-1044
[8]   Comparison of paclitaxel- and sirolimus-eluting stents in everyday clinical practice -: The SORT OUT II Randomized trial [J].
Galloe, Anders M. ;
Thuesen, Leif ;
Kelbaek, Henning ;
Thayssen, Per ;
Rasmussen, Klaus ;
Hansen, Peter R. ;
Bligaard, Niels ;
Saunamaki, Kari ;
Junker, Anders ;
Aaroe, Jens ;
Abildgaard, Ulrik ;
Ravkilde, Jan ;
Engstrom, Thomas ;
Jensen, Jan S. ;
Andersen, Henning R. ;
Botker, Hans E. ;
Galatius, Soren ;
Kristensen, Steen D. ;
Madsen, Jan K. ;
Krusell, Lars R. ;
Abildstrom, Steen Z. ;
Stephansen, Ghita B. ;
Lassen, Jens F. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2008, 299 (04) :409-416
[9]   Novel High Throughput Polymer Biocompatibility Screening Designed for SAR (Structure-Activity Relationship): Application for Evaluating Polymer Coatings for Cardiovascular Drug-Eluting Stents [J].
Hezi-Yamit, Ayala ;
Sullivan, Carol ;
Wong, Jennifer ;
David, Laura ;
Chen, Mingfei ;
Cheng, Peiwen ;
Shumaker, David ;
Wilcox, Josiah ;
Udipi, Kishore .
COMBINATORIAL CHEMISTRY & HIGH THROUGHPUT SCREENING, 2009, 12 (07) :664-676
[10]   Endothelial cell recovery between comparator polymer-based drug-eluting stents [J].
Joner, Michael ;
Nakazawa, Gaku ;
Finn, Aloke V. ;
Quee, Shawn Chin ;
Coleman, Leslie ;
Acampado, Eduardo ;
Wilson, Patricia S. ;
Skorija, Kristi ;
Cheng, Qi ;
Xu, Xin ;
Gold, Herman K. ;
Kolodgie, Frank D. ;
Virmani, Renu .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (05) :333-342