Room-temperature replacement for ge detectors - Are we there yet?

被引:24
作者
Luke, Paul N. [1 ]
Amman, Mark [1 ]
机构
[1] Univ Calif Berkeley, Lawrence Berkeley Lab, Berkeley, CA 94720 USA
关键词
gamma-ray detectors; semiconductor detectors; room-temperature gamma-ray detectors;
D O I
10.1109/TNS.2007.903184
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The search for a semiconductor detector capable of room-temperature operation with similar performance to liquid-nitrogen-cooled Ge detectors has been going on for several decades. The main challenge is in achieving the very high degree of spatial uniformity in the detector response that is needed for high-resolution gamma-ray detection. There exist two distinct paths that one can take to meet this goal. One path is to develop materials with near-perfect charge transport properties similar to that of Ge. This, requires materials with high mobilities and lifetimes for both electrons and holes, which means extremely low concentrations of electrically-active and carrier-trapping defects. The other path is to employ special device technologies that can provide a highly uniform detector response given the charge transport properties of existing room-temperature semiconductor materials. Many types of device structures and readout techniques have been proposed and investigated, but only a few have the potential to achieve near-Ge spectral performance. We will discuss the basic material and device requirements, the obtainable performance, the state of the technology, and the challenges of these different approaches.
引用
收藏
页码:834 / 842
页数:9
相关论文
共 34 条
  • [1] Electron trapping nonuniformity in high-pressure-Bridgman-grown CdZnTe
    Amman, M
    Lee, JS
    Luke, PN
    [J]. JOURNAL OF APPLIED PHYSICS, 2002, 92 (06) : 3198 - 3206
  • [2] Temperature study of CdZnTe coplanar-grid detectors
    Amman, Mark
    Lee, Julie S.
    Luke, Paul N.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (05) : 3035 - 3040
  • [3] WHAT CAN BE EXPECTED FROM HIGH-Z SEMICONDUCTOR-DETECTORS
    ARMANTROUT, GA
    SWIERKOWSKI, SP
    SHEROHMAN, JW
    YEE, JH
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1977, 24 (01) : 121 - 125
  • [4] BALE DS, 2006, P SOC PHOTO-OPT INS, V6319
  • [5] Development of portable CdZnTe spectrometers for remote sensing of signatures from nuclear materials
    Burger, A
    Groza, M
    Cui, YL
    Roy, UN
    Hillman, D
    Guo, M
    Li, LX
    Wright, GW
    James, RB
    [J]. PHYSICA STATUS SOLIDI C - CONFERENCES AND CRITICAL REVIEWS, VOL 2, NO 5, 2005, 2 (05): : 1586 - 1591
  • [6] Signal variance in gamma-ray detectors - A review
    Devanathan, R.
    Corrales, L. R.
    Gao, F.
    Weber, W. J.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 565 (02) : 637 - 649
  • [7] ESKIN JD, 1996, INT SOC OPT ENG P SP, V2859, P46
  • [8] Gostilo V, 2004, IEEE NUCL SCI CONF R, P4590
  • [9] Signal generation in CdZnTe strip detectors
    Hamel, LA
    Macri, JR
    Doty, FP
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) : 1422 - 1426
  • [10] CdZnTe Frisch collar detectors for γ-ray spectroscopy
    Kargar, A
    Jones, AM
    McNeil, WJ
    Harrison, MJ
    McGregor, DS
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 558 (02) : 497 - 503