Modulation transfer function measurement of scanning reflectance microscopes

被引:15
|
作者
Wang, Zhao [1 ]
Glazowski, Christopher E. [2 ]
Zavislan, James M. [2 ]
机构
[1] Univ Rochester, Dept Biomed Engn, Rochester, NY 14627 USA
[2] Univ Rochester, Inst Opt, Rochester, NY 14627 USA
关键词
modulation transfer functions; resolution; scanning microscopy;
D O I
10.1117/1.2779352
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Real-time medical imaging systems such as reflectance confocal microscopes and optical coherence microscopes are being tested in multiple-patient and multiple-center clinical trials. The modulation transfer function (MTF) of these systems at any given time influences the image information content and can affect the interpretation of the images. MTF is difficult to measure in real-time scanning systems when imaging at the Nyquist limit. We describe a measurement technique similar to the electronic imaging resolution standards ISO-12233 (electronic cameras) that can be applied to scanned spot imaging systems with asynchronous pixel clocks. This technique requires the acquisition of a single image of a reflective stripe object. An asynchronous pixel clock induces subpixel jitter in the edge location. The jitter is removed using a Fourier method, and an oversampled edge response function is calculated using algorithms developed in MATLAB. This technique provides fast, simple to use, and repeatable full-width at half maximum lateral resolution and MTF measurements based on only one test image. We present the results for reflectance confocal microscopes operating at 0.9 numerical aperature. (c) 2007 Society of Photo-Optical Instrumentation Engineers.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] 3-D TRANSFER-FUNCTION FOR SCANNING MICROSCOPES
    GROBLER, B
    OPTIK, 1991, 87 (01): : 41 - 42
  • [2] ON THE MEASUREMENT OF TRANSFER MODULATION FUNCTION
    NAZAROV, VB
    ZHURNAL NAUCHNOI I PRIKLADNOI FOTOGRAFII, 1993, 38 (01): : 72 - 74
  • [3] Binary pseudo-random grating as a standard test surface for measurement of modulation transfer function of interferometric microscopes
    Yashchuk, Valeriy V.
    McKinney, Wayne R.
    Takacs, Peter Z.
    ADVANCES IN METROLOGY FOR X-RAY AND EUV OPTICS II, 2007, 6704
  • [4] MODULATION TRANSFER FUNCTION OF A SCANNING MICRODENSITOMETER SLIT
    VILLAFAN.T
    BATES, LM
    PHYSICS IN MEDICINE AND BIOLOGY, 1970, 15 (02): : 371 - &
  • [5] Modulation transfer function of bar code scanning
    Tang, H
    Milster, TD
    OPTICAL ENGINEERING, 1998, 37 (09) : 2574 - 2580
  • [7] Measurement of the modulation transfer function of paper
    Rogers, GL
    APPLIED OPTICS, 1998, 37 (31): : 7235 - 7240
  • [8] Measurement of the modulation transfer function of paper
    Rogers, Geoffrey L.
    Applied Optics, 1998, 37 (31): : 7235 - 7240
  • [9] Binary pseudorandom test standard to determine the modulation transfer function of optical microscopes
    Lacey, Ian
    Anderson, Erik H.
    Artemiev, Nikolay A.
    Babin, Sergey
    Cabrini, Stefano
    Calafiore, Guiseppe
    Chan, Elaine R.
    McKinney, Wayne R.
    Peroz, Christophe
    Takacs, Peter Z.
    Yashchuk, Valeriy V.
    APPLIED ADVANCED OPTICAL METROLOGY SOLUTIONS, 2015, 9576
  • [10] MODULATION TRANSFER FUNCTION AND ITS APPLICATION TO RADIOISOTOPE SCANNING
    CRADDUCK, TD
    PHYSICS IN MEDICINE AND BIOLOGY, 1970, 15 (01): : 149 - &