Amperometric determination of hydrogen peroxide residue in beverages using a Nafion modified palladium electrode

被引:12
|
作者
Hsu, Chuan-Liang [1 ]
Jang, Hung-Der [1 ]
Su, Ming-Sheng [1 ]
Chang, Ku-Shang [1 ]
Huang, Yung-Sheng [1 ]
机构
[1] Yuanpei Univ, Dept Food Sci, Hsinchu 300, Taiwan
关键词
hydrogen peroxide; aseptic packages; amperometric detection; Nafion; ascorbic acid;
D O I
10.1007/s00217-007-0598-8
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Hydrogen peroxide (H2O2) residues are not permitted in food due to health concerns. An amperometric sensor based on a Nafion modified palladium (Pd) electrode was developed for the rapid determination of the H2O2 residue in aseptically packaged beverages. A prepared Pd electrode shows a slowly increasing reaction upon repeating the procedure of adding the same concentration of H2O2 into the reaction cell unless pretreating the electrode with cyclic voltammetry to obtain reproducible surfaces, whereas a Nafion modified Pd electrode can reach stable reaction to H2O2 without any pretreatment. The interference level of ascorbic acid (the ration of electrochemical response to ascorbic acid to the electrochemical response of H2O2) was calculated as 0.0004 for the Nafion modified Pd electrode. Interference (99.5%)from ascorbic acid was diminished by Nafion membrane. The response of the sensor to H2O2 in distilled water is linear over the range of 0.25-15 mu M (r(2)= 0.9956). The sensor developed in this study can efficiently determine H2O2 residues in commercial beverages with good linear correlation between spiked H2O2 concentration and detected H2O2 concentration, for winter melon-flavored drink, r(2)= 0.9904 in the range of 0.25-15 mu M and for lemon-flavored tea, r(2)= 0.9927 in the range of 0.25-25 mu M.
引用
收藏
页码:809 / 815
页数:7
相关论文
共 50 条
  • [41] Determination of hydrogen peroxide using a Prussian Blue modified macroporous gold electrode
    Yang, Jiao
    Lin, Meng
    Cho, MiSuk
    Lee, Youngkwan
    MICROCHIMICA ACTA, 2015, 182 (5-6) : 1089 - 1094
  • [42] An Ultrahigh Selective and Sensitive Enzyme-Free Hydrogen Peroxide Sensor Based on Palladium Nanoparticles and Nafion-Modified Electrode
    Chelladurai Karuppiah
    Selvakumar Palanisamy
    Shen-Ming Chen
    Electrocatalysis, 2014, 5 : 177 - 185
  • [43] An Ultrahigh Selective and Sensitive Enzyme-Free Hydrogen Peroxide Sensor Based on Palladium Nanoparticles and Nafion-Modified Electrode
    Karuppiah, Chelladurai
    Palanisamy, Selvakumar
    Chen, Shen-Ming
    ELECTROCATALYSIS, 2014, 5 (02) : 177 - 185
  • [44] Amperometric Sensing of Hydrogen Peroxide Using Graphene Oxide-Alizarin Modified Glassy Carbon Electrode
    Muhammet, Sinan Mithat
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2022, 17 (06):
  • [45] An Efficient Amperometric Sensor for Hydrogen Peroxide by Using a Carbon Paste Electrode Modified with Cobalt Impregnated Zeolite
    Norouzi, Banafsheh
    Moradian, Majid
    Malekan, Ali
    PORTUGALIAE ELECTROCHIMICA ACTA, 2015, 33 (02) : 111 - 124
  • [46] Flow-Injection Amperometric Determination of Adrenalin, Melatonin, and Cortisol on an Electrode Modified with a Gold-Palladium Binary System and a Nafion Film
    Shaidarova, L. G.
    Chelnokova, I. A.
    Leksina, Yu. A.
    Khairullina, D. Yu.
    Budnikov, H. C.
    INORGANIC MATERIALS, 2023, 59 (14) : 1474 - 1481
  • [47] Determination of thiocompounds by liquid chromatography with amperometric detection at a Nafion indium hexacyanoferrate film modified electrode
    Zhang, S
    Sun, WL
    Zhang, W
    Qi, WY
    Jin, LT
    Yamamoto, K
    Tao, SG
    Jin, JY
    ANALYTICA CHIMICA ACTA, 1999, 386 (1-2) : 21 - 30
  • [48] Determination of hydrogen peroxide based on calcined layered double hydroxide-modified glassy carbon electrode in flavored beverages
    Wang, Jun
    Cui, Lin
    Yin, Huanshun
    Dong, Jing
    Ai, Shiyun
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2012, 16 (04) : 1545 - 1550
  • [49] Amperometric determination of epinephrine with an osmium complex and Nafion double-layer membrane modified electrode
    Ni, JA
    Ju, HX
    Chen, HY
    Leech, D
    ANALYTICA CHIMICA ACTA, 1999, 378 (1-3) : 151 - 157
  • [50] Determination of hydrogen peroxide based on calcined layered double hydroxide-modified glassy carbon electrode in flavored beverages
    Jun Wang
    Lin Cui
    Huanshun Yin
    Jing Dong
    Shiyun Ai
    Journal of Solid State Electrochemistry, 2012, 16 : 1545 - 1550