Amperometric determination of hydrogen peroxide residue in beverages using a Nafion modified palladium electrode

被引:12
|
作者
Hsu, Chuan-Liang [1 ]
Jang, Hung-Der [1 ]
Su, Ming-Sheng [1 ]
Chang, Ku-Shang [1 ]
Huang, Yung-Sheng [1 ]
机构
[1] Yuanpei Univ, Dept Food Sci, Hsinchu 300, Taiwan
关键词
hydrogen peroxide; aseptic packages; amperometric detection; Nafion; ascorbic acid;
D O I
10.1007/s00217-007-0598-8
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Hydrogen peroxide (H2O2) residues are not permitted in food due to health concerns. An amperometric sensor based on a Nafion modified palladium (Pd) electrode was developed for the rapid determination of the H2O2 residue in aseptically packaged beverages. A prepared Pd electrode shows a slowly increasing reaction upon repeating the procedure of adding the same concentration of H2O2 into the reaction cell unless pretreating the electrode with cyclic voltammetry to obtain reproducible surfaces, whereas a Nafion modified Pd electrode can reach stable reaction to H2O2 without any pretreatment. The interference level of ascorbic acid (the ration of electrochemical response to ascorbic acid to the electrochemical response of H2O2) was calculated as 0.0004 for the Nafion modified Pd electrode. Interference (99.5%)from ascorbic acid was diminished by Nafion membrane. The response of the sensor to H2O2 in distilled water is linear over the range of 0.25-15 mu M (r(2)= 0.9956). The sensor developed in this study can efficiently determine H2O2 residues in commercial beverages with good linear correlation between spiked H2O2 concentration and detected H2O2 concentration, for winter melon-flavored drink, r(2)= 0.9904 in the range of 0.25-15 mu M and for lemon-flavored tea, r(2)= 0.9927 in the range of 0.25-25 mu M.
引用
收藏
页码:809 / 815
页数:7
相关论文
共 50 条
  • [21] MWCNT-cysteamine-Nafion modified gold electrode based on myoglobin for determination of hydrogen peroxide and nitrite
    Canbay, Erhan
    Sahin, Berika
    Kiran, Muge
    Akyilmaz, Erol
    BIOELECTROCHEMISTRY, 2015, 101 : 126 - 131
  • [22] Amperometric determination of L-cysteine using a glassy carbon electrode modified with palladium nanoparticles grown on reduced graphene oxide in a Nafion matrix
    Yusoff, Norazriena
    Rameshkumar, Perumal
    Noor, An'amt Mohamed
    Nay Ming Huang
    MICROCHIMICA ACTA, 2018, 185 (04)
  • [23] Amperometric determination of L-cysteine using a glassy carbon electrode modified with palladium nanoparticles grown on reduced graphene oxide in a Nafion matrix
    Norazriena Yusoff
    Perumal Rameshkumar
    An’amt Mohamed Noor
    Nay Ming Huang
    Microchimica Acta, 2018, 185
  • [24] Amperometric determination of hydrogen peroxide with a manganese dioxide film-modified screen printed carbon electrode
    Schachl, K
    Alemu, H
    Kalcher, K
    Moderegger, H
    Svancara, I
    Vytras, K
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 362 (02): : 194 - 200
  • [25] Amperometric determination of hydrogen peroxide with a manganese dioxide film-modified screen printed carbon electrode
    Klemens Schachl
    Hailemichael Alemu
    K. Kalcher
    Helmut Moderegger
    Ivan Svancara
    Karel Vytras
    Fresenius' Journal of Analytical Chemistry, 1998, 362 : 194 - 200
  • [26] Amperometric determination of hydrogen peroxide by direct and catalytic reduction at a copper electrode
    Somasundrum, M
    Kirtikara, K
    Tanticharoen, M
    ANALYTICA CHIMICA ACTA, 1996, 319 (1-2) : 59 - 70
  • [27] VOLTAMMETRIC REDUCTION AND DETERMINATION OF HYDROGEN-PEROXIDE AT AN ELECTRODE MODIFIED WITH A FILM CONTAINING PALLADIUM AND IRIDIUM
    COX, JA
    JAWORSKI, RK
    ANALYTICAL CHEMISTRY, 1989, 61 (19) : 2176 - 2178
  • [28] Amperometric determination of hydrogen peroxide using a copper microelectrode
    Dantas, L. M. F.
    Castro, P. S.
    Pena, R. C.
    Bertotti, M.
    ANALYTICAL METHODS, 2014, 6 (07) : 2112 - 2116
  • [29] Flow-Injection Amperometric Determination of Adrenalin, Melatonin, and Cortisol on an Electrode Modified with a Gold–Palladium Binary System and a Nafion Film
    L. G. Shaidarova
    I. A. Chelnokova
    Yu. A. Leksina
    D. Yu. Khairullina
    H. C. Budnikov
    Inorganic Materials, 2023, 59 : 1474 - 1481
  • [30] Amperometric Determination of Hydrogen Peroxide in Whitening Gels Using Boron-doped Diamond Electrode
    Azevedo, Gustavo C.
    Castro, Roberto H. S.
    Matos, Maria Auxiliadora C.
    Matos, Renato Camargo
    ANALYTICAL SCIENCES, 2018, 34 (08) : 913 - 917