Amperometric determination of hydrogen peroxide residue in beverages using a Nafion modified palladium electrode

被引:12
|
作者
Hsu, Chuan-Liang [1 ]
Jang, Hung-Der [1 ]
Su, Ming-Sheng [1 ]
Chang, Ku-Shang [1 ]
Huang, Yung-Sheng [1 ]
机构
[1] Yuanpei Univ, Dept Food Sci, Hsinchu 300, Taiwan
关键词
hydrogen peroxide; aseptic packages; amperometric detection; Nafion; ascorbic acid;
D O I
10.1007/s00217-007-0598-8
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Hydrogen peroxide (H2O2) residues are not permitted in food due to health concerns. An amperometric sensor based on a Nafion modified palladium (Pd) electrode was developed for the rapid determination of the H2O2 residue in aseptically packaged beverages. A prepared Pd electrode shows a slowly increasing reaction upon repeating the procedure of adding the same concentration of H2O2 into the reaction cell unless pretreating the electrode with cyclic voltammetry to obtain reproducible surfaces, whereas a Nafion modified Pd electrode can reach stable reaction to H2O2 without any pretreatment. The interference level of ascorbic acid (the ration of electrochemical response to ascorbic acid to the electrochemical response of H2O2) was calculated as 0.0004 for the Nafion modified Pd electrode. Interference (99.5%)from ascorbic acid was diminished by Nafion membrane. The response of the sensor to H2O2 in distilled water is linear over the range of 0.25-15 mu M (r(2)= 0.9956). The sensor developed in this study can efficiently determine H2O2 residues in commercial beverages with good linear correlation between spiked H2O2 concentration and detected H2O2 concentration, for winter melon-flavored drink, r(2)= 0.9904 in the range of 0.25-15 mu M and for lemon-flavored tea, r(2)= 0.9927 in the range of 0.25-25 mu M.
引用
收藏
页码:809 / 815
页数:7
相关论文
共 50 条
  • [1] Amperometric determination of hydrogen peroxide residue in beverages using a Nafion modified palladium electrode
    Chuan-Liang Hsu
    Hung-Der Jang
    Ming-Sheng Su
    Ku-Shang Chang
    Yung-Sheng Huang
    European Food Research and Technology, 2008, 226 : 809 - 815
  • [2] Determination of hydrogen peroxide residues in aseptically packaged beverages using an amperometric sensor based on a palladium electrode
    Hsu, Chuan-Liang
    Chang, Ku-Shang
    Kuo, Ju-Chia
    FOOD CONTROL, 2008, 19 (03) : 223 - 230
  • [3] Selective amperometric sensing of hydrogen peroxide with Nafion/copper particulates chemically modified electrode
    Kumar, Annamalai Senthil
    Sornambikai, Sundaram
    INDIAN JOURNAL OF CHEMISTRY SECTION A-INORGANIC BIO-INORGANIC PHYSICAL THEORETICAL & ANALYTICAL CHEMISTRY, 2009, 48 (07): : 940 - 945
  • [4] Nanomolar amperometric sensing of hydrogen peroxide using a graphite pencil electrode modified with palladium nanoparticles
    Aziz, Md Abdul
    Kawde, Abdel-Nasser
    MICROCHIMICA ACTA, 2013, 180 (9-10) : 837 - 843
  • [5] Nanomolar amperometric sensing of hydrogen peroxide using a graphite pencil electrode modified with palladium nanoparticles
    Md. Abdul Aziz
    Abdel-Nasser Kawde
    Microchimica Acta, 2013, 180 : 837 - 843
  • [6] Amperometric determination of calcium ion with an alizarin/Nafion modified electrode
    Jo, GB
    Won, MS
    Shim, YB
    ELECTROANALYSIS, 1999, 11 (12) : 885 - 890
  • [7] An amperometric sensor based on Prussian blue and poly(o-phenylenediamine) modified glassy carbon electrode for the determination of hydrogen peroxide in beverages
    Ping, Jianfeng
    Wu, Jian
    Fan, Kai
    Ying, Yibin
    FOOD CHEMISTRY, 2011, 126 (04) : 2005 - 2009
  • [8] Methylene Blue/Multiwall Carbon Nanotube Modified Electrode for the Amperometric Determination of Hydrogen Peroxide
    Pena, Roselyn C.
    Bertotti, Mauro
    Brett, Christopher M. A.
    ELECTROANALYSIS, 2011, 23 (10) : 2290 - 2296
  • [9] Nonenzymatic amperometric determination of hydrogen peroxide by graphene and gold nanorods nanocomposite modified electrode
    Pang, Pengfei
    Yang, Zhongming
    Xiao, Shixiu
    Xie, Jinling
    Zhang, Yanli
    Gao, Yuntao
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2014, 727 : 27 - 33
  • [10] Electrochemical determination of hydrogen peroxide at a glassy carbon electrode modified with palladium nanoparticles
    Kitte, Shimeles Addisu
    Assresahegn, Birhanu Desalegn
    Soreta, Tesfaye Refera
    JOURNAL OF THE SERBIAN CHEMICAL SOCIETY, 2013, 78 (05) : 701 - 711