High-rate dissolved air flotation for water treatment

被引:0
|
作者
Reali, MAP [1 ]
Marchetto, M [1 ]
机构
[1] Univ Sao Paulo, EESC, Sao Carlos Sch Engn, Dept Hydraul & Sanitat, BR-13560250 Sao Carlos, SP, Brazil
关键词
dissolved air flotation; DAF; flotation; high rate flotation; water treatment; water clarification;
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper presents the results of an experimental investigation about the performance of a horizontal flow high-rate pilot scale Dissolved Air Flotation (HRDAF) unit containing inclined parallel plates for treating a coloured and low turbidity raw water. Experiments were performed with the DAF unit in order to verify the influence on flotation of : (i) the water velocity (Vh) between the plates, in the range 18 to 96.5 cm.min(-1) with corresponding Reynolds numbers between 240 and 1060; (ii) the supplied air (S-*) value ranging from 2.2 to 8.5 g of air/m(3) of water; (iii) the angle of the plates (60 degrees or 70 degrees). The best pilot plant operational condition was obtained applying only 4.0 g/m(3) (S*) with Vh around 18 cm.min(-1) for treatment of water coagulated with a AI,(SO,), dosage of 40 mg.l(-1). in these conditions, the unit presented very good removal efficiencies of colour (90%, residual of 10 uC), turbidity (88%, residual of 0.8 NTU) and TSS (94%, residual of 1.8 mg.l(-1)). Furthermore, the unit could operate at higher Vh values up to 76 cm.min(-1) and still present good results. The DAF unit thus behaved as a high rate unit presenting good performance with low air requirement.
引用
收藏
页码:43 / 49
页数:7
相关论文
共 50 条