In-channel dual-electrode amperometric detection in electrophoretic chips with a palladium film decoupler

被引:26
|
作者
Lai, CCJ
Chen, CH
Ko, FH [1 ]
机构
[1] Natl Tsing Hua Univ, Dept Chem, Hsinchu 30013, Taiwan
[2] Natl Nano Device Labs, Hsinchu 30050, Taiwan
关键词
palladium film decoupler; dual-electrode detection; chip technology; amperometric detection;
D O I
10.1016/j.chroma.2003.09.053
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An electrophoretic microchip integrated with a Pd-film decoupler and a series-dual electrode was proven practical (200-800V/cm) for routine amperometric detection. In fluidic systems, amperometric enhancement of parallel-opposed dual-electrode detection is due to redox cycling of analytes between the electrodes. We, however, found that the oxidation current of catecholamines was enhanced significantly (1.9-3.8 folds) by switching from the single electrode mode to dual-series mode. This novel finding was unexpected because the unidirectional flow characteristic of the microfluidic system should eliminate the possibility for analytes physically migrating back and forth between the upstream and downstream electrodes. We attribute the enhancement to turbulence generated by impinging of the flow onto the edge of the downstream electrode. The linear range, sensitivity, limit of detection (S/N = 3) and number of theoretical plates for DA and CA are, respectively, 0.5-50 muM. 47 pA/muM, 0.25 muM, 7000 m(-1), and 1.0-100 muM, 28 pA/muM, 0.49 muM, 15 000 m(-1). (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:143 / 150
页数:8
相关论文
共 50 条
  • [1] Palladium film decoupler for amperometric detection in electrophoresis chips
    Chen, DC
    Hsu, FL
    Zhan, DZ
    Chen, CH
    ANALYTICAL CHEMISTRY, 2001, 73 (04) : 758 - 762
  • [2] Nanoband electrode for high-performance in-channel amperometric detection in dual-channel microchip capillary electrophoresis
    Chen, Chuanpin
    Teng, Wei
    Hahn, Jong Hoon
    ELECTROPHORESIS, 2011, 32 (08) : 838 - 843
  • [3] Determination of urine catecholamines by capillary electrophoresis with dual-electrode amperometric detection
    Chen, D
    Zhan, DZ
    Cheng, CW
    Liu, AC
    Chen, C
    JOURNAL OF CHROMATOGRAPHY B, 2001, 750 (01): : 33 - 39
  • [4] DETERMINATION OF NITRODIPHENYLAMINES BY LIQUID-CHROMATOGRAPHY AND DUAL-ELECTRODE AMPEROMETRIC DETECTION
    BERGENS, A
    JOURNAL OF CHROMATOGRAPHY, 1987, 410 (02): : 437 - 446
  • [5] Use of micromolded carbon dual electrodes with a palladium decoupler for amperometric detection in microchip electrophoresis
    Mecker, Laura C.
    Martin, R. Scott
    ELECTROPHORESIS, 2006, 27 (24) : 5032 - 5042
  • [6] Pyrolyzed photoresist carbon electrodes for microchip electrophoresis with dual-electrode amperometric detection
    Fischer, DJ
    Vandaveer, WR
    Grigsby, RJ
    Lunte, SM
    ELECTROANALYSIS, 2005, 17 (13) : 1153 - 1159
  • [7] In-channel simplified decoupler with renewable electrochemical detection for microchip capillary electrophoresis
    Lin, Kuan-Wen
    Huang, Yan-Kai
    Su, Hsiu-Li
    Hsieh, You-Zung
    ANALYTICA CHIMICA ACTA, 2008, 619 (01) : 115 - 121
  • [8] APPARENT INTER-CHANNEL INTERFERENCE IN DUAL-ELECTRODE ELECTROCHEMICAL DETECTION
    DEMPSEY, CA
    LAVICKY, J
    DUNN, AJ
    JOURNAL OF CHROMATOGRAPHY, 1992, 596 (01): : 110 - 113
  • [10] A new dual-electrode and dual-channel electrochemical detection system for capillary electrophoresis
    Yang, BY
    Mo, JY
    Lai, R
    ACTA CHIMICA SINICA, 2003, 61 (09) : 1461 - 1465