Concentrations and decay rates of ozone in indoor air in dependence on building and surface materials

被引:26
|
作者
Moriske, HJ [1 ]
Ebert, G [1 ]
Konieczny, L [1 ]
Menk, G [1 ]
Schöndube, M [1 ]
机构
[1] Fed Environm Agcy, Inst Water Soil & Air Hyg, D-14195 Berlin, Germany
关键词
ozone; formaldehyde; indoor air pollution; building material; surface material;
D O I
10.1016/S0378-4274(98)00088-5
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 ;
摘要
The decay of ozone in indoor air was measured in a closed chamber after contact with different building materials and residential surfaces. The tested materials were: vinyl wall paper, woodchip paper, plywood, latex paint, fitted carpet, and plaster. In the summer of 1996, the entry of ozone from ambient air into indoor air during ventilation and the ozone decay in indoor air, after windows had been closed again, were studied. Measurements were done in a residential house on the outskirts of Berlin. The following results were gained: the chamber measurements showed a decay of ozone after contact with most of the materials put inside the chamber. Higher decay rates have been obtained for wall papers, plywood, fitted carpet and plaster. As described in the literature, ozone is able to react with olefines inside the materials and is able to form formaldehyde and other components. This formation of formaldehyde could also be confirmed in our investigations. Thus, in most cases, the formaldehyde concentrations were lower than the German guideline value of 0.1 ppm. The formation of formaldehyde could be prevented when a special wall paper that was coated with activated carbon was used. In the house, a complete ozone diffusion into indoor air took place during ventilation within 30 min. After closing the windows, the ozone concentrations decreased to the basic level before ventilation within 60-90 min. (C) 1998 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:319 / 323
页数:5
相关论文
共 50 条
  • [1] CONCENTRATIONS, DECAY RATES, AND REMOVAL OF OZONE AND THEIR RELATION TO ESTABLISHING CLEAN INDOOR AIR
    SABERSKY, RH
    SINEMA, DA
    SHAIR, FH
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1973, 7 (04) : 347 - 353
  • [2] Radionuclides in building materials and radon indoor concentrations
    Popovic, D
    Djuric, G
    Todorovic, D
    RADIATION PROTECTION DOSIMETRY, 1996, 63 (03) : 223 - 225
  • [3] Ozone reactions with indoor materials during building disinfection
    Poppendieck, D.
    Hubbard, H.
    Ward, M.
    Weschler, C.
    Corsi, R. L.
    ATMOSPHERIC ENVIRONMENT, 2007, 41 (15) : 3166 - 3176
  • [4] Trends of ozone surface concentrations and their dependence on solar activity
    Zvyagintsev, AM
    Kruchenitskii, GM
    GEOMAGNETIZM I AERONOMIYA, 1996, 36 (02): : 163 - 166
  • [5] Surface Radon Exhalation Rates of Building Material and Soil Affect on Indoor Air Radon Concentration
    He Xiaofeng
    Wang Guosheng
    SECOND SREE CONFERENCE ON CHEMICAL ENGINEERING (CCE 2011), 2011, 18
  • [6] BUILDING-MATERIALS AND INDOOR AIR-QUALITY
    LEVIN, H
    OCCUPATIONAL MEDICINE-STATE OF THE ART REVIEWS, 1989, 4 (04): : 667 - 693
  • [7] INDOOR AIR-POLLUTION BY BUILDING-MATERIALS
    WANNER, HU
    KUHN, M
    ZENTRALBLATT FUR BAKTERIOLOGIE MIKROBIOLOGIE UND HYGIENE SERIE B-UMWELTHYGIENE KRANKENHAUSHYGIENE ARBEITSHYGIENE PRAVENTIVE MEDIZIN, 1983, 178 (04): : 406 - 406
  • [8] Exponential Decay Model of TVOC Emission from Indoor Building Materials
    Zhang, Y.
    Niu, Y. R.
    Liu, Y.
    Wu, Y. F.
    Jiang, J. X.
    Guan, H. Y.
    Guo, Z. B.
    4TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL ENGINEERING AND SUSTAINABLE DEVELOPMENT (CEESD 2019), 2020, 435
  • [9] Ozone and other photochemical oxidants in ambient and indoor air - Properties, sources and concentrations
    Sundell, J
    Zuber, A
    SCANDINAVIAN JOURNAL OF WORK ENVIRONMENT & HEALTH, 1996, 22 : 5 - &
  • [10] OZONE IN RESIDENTIAL AIR - CONCENTRATIONS, I/O RATIOS, INDOOR CHEMISTRY, AND EXPOSURES
    ZHANG, JF
    LIOY, PJ
    INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1994, 4 (02): : 95 - 105