Compressed Sensing With Wavelet Domain Dependencies for Coronary MRI: A Retrospective Study

被引:37
作者
Akcakaya, Mehmet [1 ,2 ]
Nam, Seunghoon [1 ,2 ]
Hu, Peng [2 ]
Moghari, Mehdi H. [2 ]
Ngo, Long H. [2 ]
Tarokh, Vahid [1 ]
Manning, Warren J. [3 ,4 ]
Nezafat, Reza [2 ]
机构
[1] Harvard Univ, Sch Engn & Appl Sci, Cambridge, MA 02138 USA
[2] Harvard Univ, Beth Israel Deaconess Med Ctr, Sch Med, Dept Med, Boston, MA 02215 USA
[3] Harvard Univ, Beth Israel Deaconess Med Ctr, Sch Med, Dept Med, Boston, MA 02138 USA
[4] Harvard Univ, Beth Israel Deaconess Med Ctr, Sch Med, Dept Radiol, Boston, MA 02138 USA
关键词
Accelerated imaging; compressed sensing; coronary artery disease; coronary magnetic resonance imaging (MRI); wavelet domain dependencies; MAGNETIC-RESONANCE ANGIOGRAPHY; STATE FREE PRECESSION; IMAGE-RECONSTRUCTION; SCALE MIXTURES; BREATH-HOLD; CONTRAST; CONSTRAINT; TRANSFORM; ALGORITHM;
D O I
10.1109/TMI.2010.2089519
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Coronary magnetic resonance imaging (MRI) is a noninvasive imaging modality for diagnosis of coronary artery disease. One of the limitations of coronary MRI is its long acquisition time due to the need of imaging with high spatial resolution and constraints on respiratory and cardiac motions. Compressed sensing (CS) has been recently utilized to accelerate image acquisition in MRI. In this paper, we develop an improved CS reconstruction method, Bayesian least squares-Gaussian scale mixture (BLS-GSM), that uses dependencies of wavelet domain coefficients to reduce the observed blurring and reconstruction artifacts in coronary MRI using traditional l(1) regularization. Images of left and right coronary MRI was acquired in 7 healthy subjects with fully-sampled k-space data. The data was retrospectively undersampled using acceleration rates of 2, 4, 6, and 8 and reconstructed using l(1) thresholding, l(1) minimization and BLS-GSM thresholding. Reconstructed right and left coronary images were compared with fully-sampled reconstructions in vessel sharpness and subjective image quality (1-4 for poor-excellent). Mean square error (MSE) was also calculated for each reconstruction. There were no significant differences between the fully sampled image score versus rate 2, 4, or 6 for BLS-GSM for both right and left coronaries (= N.S.) However, for l(1) thresholding significant differences (p < 0.05) were observed for rates higher than 2 and 4 for right and left coronaries respectively. minimization also yields images with lower scores compared to the reference for rates higher than 4 for both coronaries. These results were consistent with the quantitative vessel sharpness readings. BLS-GSM allows acceleration of coronary MRI with acceleration rates beyond what can be achieved with l(1) regularization.
引用
收藏
页码:1090 / 1099
页数:10
相关论文
共 46 条
[11]   Improving Non-contrast-Enhanced Steady-State Free Precession Angiography with Compressed Sensing [J].
Cukur, Tolga ;
Lustig, Michael ;
Nishimura, Dwight G. .
MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (05) :1122-1131
[12]   An iterative thresholding algorithm for linear inverse problems with a sparsity constraint [J].
Daubechies, I ;
Defrise, M ;
De Mol, C .
COMMUNICATIONS ON PURE AND APPLIED MATHEMATICS, 2004, 57 (11) :1413-1457
[13]   FAST ALGORITHMS FOR LOW-LEVEL VISION [J].
DERICHE, R .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1990, 12 (01) :78-87
[14]   Compressed sensing [J].
Donoho, DL .
IEEE TRANSACTIONS ON INFORMATION THEORY, 2006, 52 (04) :1289-1306
[15]   IDEAL SPATIAL ADAPTATION BY WAVELET SHRINKAGE [J].
DONOHO, DL ;
JOHNSTONE, IM .
BIOMETRIKA, 1994, 81 (03) :425-455
[16]   Soap-bubble visualization and quantitative analysis of 3D coronary magnetic resonance angiograms [J].
Etienne, A ;
Botnar, RM ;
van Muiswinkel, AMC ;
Boesiger, P ;
Manning, WJ ;
Stuber, M .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (04) :658-666
[17]   An EM algorithm for wavelet-based image restoration [J].
Figueiredo, MAT ;
Nowak, RD .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 2003, 12 (08) :906-916
[18]  
FISCHER A, 2009, 17 SCI M INT SOC MAG
[19]   Compressed sensing in dynamic MRI [J].
Gamper, Urs ;
Boesiger, Peter ;
Kozerke, Sebastian .
MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (02) :365-373
[20]  
Huber ME, 2004, MAGN RESON MED, V52, P221, DOI [10.1002/mrm.20062, 10.1002/MRM.20062]