Performance investigation of a new cooling, heating and power system with methanol decomposition based chemical recuperation process

被引:23
作者
Bai, Zhang [1 ,2 ,3 ]
Liu, Taixiu [2 ,3 ]
Liu, Qibin [2 ,3 ]
Lei, Jing [4 ]
Gong, Liang [1 ]
Jin, Hongguang [2 ,3 ]
机构
[1] China Univ Petr East China, Coll Pipeline & Civil Engn, Qingdao 266580, Peoples R China
[2] Chinese Acad Sci, Inst Engn Thermophys, Beijing 100190, Peoples R China
[3] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[4] North China Elect Power Univ, Sch Energy Power & Mech Engn, Beijing 102206, Peoples R China
基金
中国国家自然科学基金;
关键词
Combined cooling; heating and power; Chemical recuperation; Methanol decomposition; System evaluation; INTERNAL-COMBUSTION ENGINE; CCHP SYSTEM; ABSORPTION-REFRIGERATION; EXERGY-ANALYSIS; OPTIMIZATION MODEL; GENERATION SYSTEM; RENEWABLE ENERGY; SOLAR; BIOMASS; DRIVEN;
D O I
10.1016/j.apenergy.2018.07.112
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A novel combined cooling, heating and power system, which mainly consists of an internal combustion engine power block with the capacity of 500 kW a chemical recuperation block, an absorption refrigeration block and a hot water supply block, is proposed to improve the energy conversion efficiency in this work. The high temperature exhaust gas from the internal combustion engine is first used to drive methanol decomposition to produce syngas of CO and H-2 via the chemical recuperation, and the produced syngas is fed into the ICE for power generation. The exit exhaust gas flows into a double-effect lithium bromide-water absorption refrigerator, and finally the rest of the gas sensible heat is used to generate hot water for district heating. The temperature of the exhaust gas reduces to approximately 280 degrees C by the chemical recuperation process, and the temperature difference between the heat resource and the absorption cooling requirement thereby decreases and leads to lower exergy loss. Numerical simulation results indicate that the developed combined cooling, heating and power system achieves favorable thermodynamic performances, and the matching characteristics between energy production and energy demand can be enhanced. The system annual averaged energy efficiency is increased to 58.05%, and the methanol consumption is reduced to 842.54 tons/year with an annual primary energy saving ratio of 9.75%. Additionally, the system achieves lower annual total cost, i.e., 538.95 k$. The research findings provide a promising method to improve the performances of the combined cooling, heating and power system.
引用
收藏
页码:1152 / 1163
页数:12
相关论文
共 34 条
  • [1] Exergy modeling of a new solar driven trigeneration system
    Al-Sulaiman, Fahad A.
    Dincer, Ibrahim
    Hamdullahpur, Feridun
    [J]. SOLAR ENERGY, 2011, 85 (09) : 2228 - 2243
  • [2] Investigation on the mid-temperature solar thermochemical power generation system with methanol decomposition
    Bai, Zhang
    Liu, Qibin
    Lei, Jing
    Jin, Hongguang
    [J]. APPLIED ENERGY, 2018, 217 : 56 - 65
  • [3] New solar-biomass power generation system integrated a two-stage gasifier
    Bai, Zhang
    Liu, Qibin
    Lei, Jing
    Hong, Hui
    Jin, Hongguang
    [J]. APPLIED ENERGY, 2017, 194 : 310 - 319
  • [4] A detailed MILP optimization model for combined cooling, heat and power system operation planning
    Bischi, Aldo
    Taccari, Leonardo
    Martelli, Emanuele
    Amaldi, Edoardo
    Manzolini, Giampaolo
    Silva, Paolo
    Campanari, Stefano
    Macchi, Ennio
    [J]. ENERGY, 2014, 74 : 12 - 26
  • [5] Investigation of an ammonia-water combined power and cooling system driven by the jacket water and exhaust gas heat of an internal combustion engine
    Chen, Yi
    Han, Wei
    Jin, Hongguang
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 82 : 174 - 188
  • [6] Combined cooling, heating and power: A review of performance improvement and optimization
    Cho, Heejin
    Smith, Amanda D.
    Mago, Pedro
    [J]. APPLIED ENERGY, 2014, 136 : 168 - 185
  • [7] Combined cooling, heat and power planning under uncertainty
    Ersoz, Ibrahim
    Colak, Uner
    [J]. ENERGY, 2016, 109 : 1016 - 1025
  • [8] Thermodynamic performance assessment of CCHP system driven by different composition gas
    Gao, Penghui
    Li, Wangliang
    Cheng, Yongpan
    Tong, YenWah
    Dai, Yanjun
    Wang, Ruzhu
    [J]. APPLIED ENERGY, 2014, 136 : 599 - 610
  • [9] Second law analysis of double effect vapour absorption cooler system
    Gomri, Rabah
    Hakimi, Riad
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2008, 49 (11) : 3343 - 3348
  • [10] A probability constrained multi-objective optimization model for CCHP system operation decision support
    Hu, Mengqi
    Cho, Heejin
    [J]. APPLIED ENERGY, 2014, 116 : 230 - 242