Square FRP-HSC-steel composite columns: Behavior under axial compression

被引:71
作者
Fanggi, Butje Alfonsius Louk [1 ]
Ozbakkaloglu, Togay [1 ]
机构
[1] Univ Adelaide, Sch Civil Environm & Min Engn, Adelaide, SA 5005, Australia
关键词
Fiber reinforced polymer (FRP); Concrete; High-strength concrete (HSC); Columns; Confinement; FRP tubes; Steel tubes; Square DSTCs; HIGH-STRENGTH CONCRETE; SKIN TUBULAR COLUMNS; REINFORCED POLYMER TUBES; CONFINED CONCRETE; FLEXURAL BEHAVIOR; SEISMIC PERFORMANCE; CFRP; MEMBERS; BEAMS;
D O I
10.1016/j.engstruct.2015.03.005
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents an experimental study, which investigated the compressive behavior of square fiber reinforced polymer (FRP)-concrete composite columns through the tests of 40 column specimens. 24 FRP-concrete-steel double-skin tubular columns (DSTCs), four concrete-filled FRP tubes (CFFTs), and 12 CFFTs with inner voids (H-CFFTs) were tested under axial compression. The majority of the specimens were manufactured using high-strength concrete (HSC). The key parameters examined included the influence of the strength of the concrete, cross-sectional shape (i.e. circular and square) and dimension of the inner steel tube, and presence (or absence) of a concrete filling inside the steel tube. The results of the DSTCs with circular inner steel tubes indicate that concrete-filling inner tubes results in an increase in the ultimate axial stress but a decrease in the ultimate axial strain of concrete compared to those seen in DSTCs with hollow inner steel tubes. It is obseived that concrete in hollow DSTCs manufactured with square inner steel tubes develop significantly lower ultimate axial stresses and strains than concrete in companion hollow DSTCs with circular inner steel tubes. It is found, however, that the performance of these specimens improves dramatically when the square inner steel tube is filled with concrete. Comparisons of the results indicate that concrete in filled DSTCs develops larger ultimate axial stresses and strains than concrete in companion CFFTs. Finally, the results demonstrate that H-CFFTs perform significantly worse than DSTCs and CFFTs, and their performance further degrade as the diameter of the inner void increases. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:156 / 171
页数:16
相关论文
共 45 条
[1]   Behavior of Large-Scale Concrete Columns Wrapped with CFRP and SFRP Sheets [J].
Abdelrahman, Khaled ;
El-Hacha, Raafat .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2012, 16 (04) :430-439
[2]   Behavior of FRP-HSC-Steel Double-Skin Tubular Columns under Cyclic Axial Compression [J].
Albitar, Mohammad ;
Ozbakkaloglu, Togay ;
Fanggi, Butje Alfonsius Louk .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2015, 19 (02)
[3]  
[Anonymous], 2008, ASTMD3039
[4]   Monotonic axial behavior and modelling of RC circular columns confined with CFRP [J].
Chastre, Carlos ;
Silva, Manuel A. G. .
ENGINEERING STRUCTURES, 2010, 32 (08) :2268-2277
[5]   Seismic retrofit of reinforced concrete short columns by CFRP materials [J].
Colomb, F. ;
Tobbi, H. ;
Ferrier, E. ;
Hamelin, P. .
COMPOSITE STRUCTURES, 2008, 82 (04) :475-487
[6]   Structural Evaluation of Full-Scale FRP-Confined Reinforced Concrete Columns [J].
De Luca, Antonio ;
Nardone, Fabio ;
Matta, Fabio ;
Nanni, Antonio ;
Lignola, Gian Piero ;
Prota, Andrea .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2011, 15 (01) :112-123
[7]   Rectangular filament-wound glass fiber reinforced polymer tubes filled with concrete under flexural and axial loading: Experimental investigation [J].
Fam, A ;
Schnerch, D ;
Rizkalla, S .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2005, 9 (01) :25-33
[8]  
Fam AZ, 2001, ACI STRUCT J, V98, P451
[9]   Compressive behavior of aramid FRP-HSC-steel double-skin tubular columns [J].
Fanggi, Butje Alfonsius Louk ;
Ozbakkaloglu, Togay .
CONSTRUCTION AND BUILDING MATERIALS, 2013, 48 :554-565
[10]   Flexural behavior of FRP-HSC-steel double skin tubular beams under reversed-cyclic loading [J].
Idris, Yunita ;
Ozbakkaloglu, Togay .
THIN-WALLED STRUCTURES, 2015, 87 :89-101