Amplified detection of hepatitis B virus using an electrochemical DNA biosensor on a nanoporous gold platform

被引:44
作者
Ahangar, Laleh Enayati [1 ]
Mehrgardi, Masoud A. [1 ]
机构
[1] Univ Isfahan, Dept Chem, Esfahan 8174673441, Iran
关键词
Nanoporous gold electrode; Electrochemical DNA hybridization biosensor; Polymerase chain reaction (PCR); Ferrocene carboxylic acid; Hepatitis B virus; POLYMERASE-CHAIN-REACTION; NUCLEIC-ACID BIOSENSOR; INDICATOR; MICROSPHERES; PATHOGENS; ELECTRODE; ELISA; ASSAY;
D O I
10.1016/j.bioelechem.2017.06.006
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
In the present study, a nanoporous gold platform was applied for the amplified detection of Hepatitis B virus (HBV) by an electrochemical DNA biosensor. Ferrocene as a redox reporter was covalently attached to the DNA probe and its electrochemical signal was recorded as the biosensor response. For real samples, DNA was firstly extracted from blood of patients and then amplified by polymerase chain reaction (PCR) for 5 cycles. Sensitivity of this biosensor was enhanced by using nanoporous gold electrode, therefore this sensor can discriminate the genome of HBV in real sample with low PCR cycles. By this strategy and signal amplification using nanoporous platform and covalently attached electroactive label, the biosensor can distinguish between healthy and HBV patients with limited PCR cycles. Moreover, the errors of PCR with large cycles can be disregarded. A linear dynamic range of 0.4 to 10 nmol of mutant DNA was achieved, with reliable reproducibility (RSD) 8.9%. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:83 / 88
页数:6
相关论文
共 32 条
[1]   Nanoporous gold electrode as a platform for the construction of an electrochemical DNA hybridization biosensor [J].
Ahangar, Laleh Enayati ;
Mehrgardi, Masoud A. .
BIOSENSORS & BIOELECTRONICS, 2012, 38 (01) :252-257
[2]   Gold electrodes from recordable CDs [J].
Angnes, L ;
Richter, EM ;
Augelli, MA ;
Kume, GH .
ANALYTICAL CHEMISTRY, 2000, 72 (21) :5503-5506
[3]  
BAKER BL, 1991, HEPATOLOGY, V13, P632, DOI 10.1002/hep.1840130404
[4]   MONITORING THE NATURAL COURSE AND RESPONSE TO THERAPY OF CHRONIC HEPATITIS-B WITH AN AUTOMATED SEMIQUANTITATIVE ASSAY FOR IGM ANTI-HBC [J].
BRUNETTO, MR ;
CERENZIA, MT ;
OLIVERI, F ;
PIANTINO, P ;
RANDONE, A ;
CALVO, PL ;
MANZINI, P ;
ROCCA, G ;
GALLI, C ;
BONINO, F .
JOURNAL OF HEPATOLOGY, 1993, 19 (03) :431-436
[5]   A review on viral biosensors to detect human pathogens [J].
Caygill, Rebecca L. ;
Blair, G. Eric ;
Millner, Paul A. .
ANALYTICA CHIMICA ACTA, 2010, 681 (1-2) :8-15
[6]   B/C genotyping of hepatitis B virus based on dual-probe electrochemical biosensor [J].
Chen, Jinyuan ;
Liu, Zhoujie ;
Zheng, Yanjie ;
Lin, Zhen ;
Sun, Zhouliang ;
Liu, Ailin ;
Chen, Wei ;
Lin, Xinhua .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 785 :75-79
[7]   Application of SPR biosensor for medical diagnostics of human hepatitis B virus (hHBV) [J].
Chung, JW ;
Kim, SD ;
Bernhardt, R ;
Pyun, JC .
SENSORS AND ACTUATORS B-CHEMICAL, 2005, 111 :416-422
[8]   Developing a double-antigen sandwich ELISA for effective detection of human hepatitis B core antibody [J].
Deng, Li-Juan ;
Xu, Yan ;
Huang, Jian .
COMPARATIVE IMMUNOLOGY MICROBIOLOGY AND INFECTIOUS DISEASES, 2008, 31 (06) :515-526
[9]   Hybridization biosensor using 2,9-dimethyl-1,10-phenantroline cobalt as electrochemical indicator for detection of hepatitis B virus DNA [J].
Ding, Caifeng ;
Zhao, Fei ;
Zhang, Meiling ;
Zhang, Shusheng .
BIOELECTROCHEMISTRY, 2008, 72 (01) :28-33
[10]   Electrochemical genomagnetic assay for the detection of hepatitis B virus DNA in polymerase chain reaction amplicons by using disposable sensor technology [J].
Erdem, A ;
Ariksoysal, DO ;
Karadeniz, H ;
Kara, P ;
Sengonul, A ;
Sayiner, AA ;
Ozsoz, M .
ELECTROCHEMISTRY COMMUNICATIONS, 2005, 7 (08) :815-820