Feasibility of the Radner Reading Charts in low-vision patients

被引:26
作者
Burggraaff, Marloes C. [1 ,2 ]
van Nispen, Ruth M. A. [1 ,2 ]
Hoek, Sharon [1 ,2 ]
Knol, Dirk L. [3 ]
van Rens, Ger H. M. B. [1 ,4 ]
机构
[1] Vrije Univ Amsterdam Med Ctr, Dept Ophthalmol, NL-1007 MB Amsterdam, Netherlands
[2] Vrije Univ Amsterdam Med Ctr, EMGO Inst Hlth & Care Res, NL-1007 MB Amsterdam, Netherlands
[3] Vrije Univ Amsterdam Med Ctr, Dept Epidemiol & Biostat, NL-1007 MB Amsterdam, Netherlands
[4] Elkerliek Hosp, Dept Ophthalmol, Helmond, Netherlands
关键词
Radner Reading Charts; Reliability; Low vision; Reading acuity; DUTCH VERSION; RELIABILITY; ACUITY; PERFORMANCE; SENTENCES; DESIGN; CARDS; AIDS;
D O I
10.1007/s00417-010-1402-1
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Being unable to read is a major problem for visually impaired patients. Since distance visual acuity (VA) does not adequately reflect reading ability, it is important to also evaluate near VA. The Radner Reading Charts (RRCs) are available to measure patients' reading performance. The present study tested the inter-chart and test-retest reliability of the RRCs in Dutch low-vision patients (i.e., visual acuity a parts per thousand yen0.3 logMAR) with various eye disorders. Thirty-eight patients read the three RRCs in random order. Then, about 1 month after the initial measurements, a test-retest procedure was performed in 15 of the 38 patients. Tested variables were reading acuity (logRAD), logRAD score, logRAD/logMAR ratio, maximum reading speed (MRS), and critical print size (CPS). Both MRS and CPS were calculated in two different ways. To determine the variability, a mixed-model analysis was used. For all variables, the largest part of the variance was explained by the individual subject (86-89%) whereas the chart accounted for only 0-0.78% of the variability. Therefore, the inter-chart and test-retest reliability was high, except for the CPS which had a poor to moderate reliability (31-62%) when calculated in the two different ways. The inter-chart and test-retest results showed high reliability in patients with low vision due to various diseases; therefore, the charts are feasible to determine effects in large groups.
引用
收藏
页码:1631 / 1637
页数:7
相关论文
共 34 条
[1]   PRINTED CARDS FOR MEASURING LOW-VISION READING SPEED [J].
AHN, SJ ;
LEGGE, GE ;
LUEBKER, A .
VISION RESEARCH, 1995, 35 (13) :1939-1944
[2]   Design of short Spanish sentences for measuring reading performance:: Radner-Vissum test [J].
Alio, Jorge L. ;
Radner, Wolfgang ;
Plaza-Puche, Ana B. ;
Ortiz, Dolores ;
Carmen Neipp, M. ;
Jose Quiles, M. ;
Rodriguez-Marin, Jesus .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (04) :638-642
[3]  
BAILEY IL, 1980, AM J OPTOM PHYS OPT, V57, P378
[4]   Direct likelihood analysis versus simple forms of imputation for missing data in randomized clinical trials [J].
Beunckens, C ;
Molenberghs, G ;
Kenward, MG .
CLINICAL TRIALS, 2005, 2 (05) :379-386
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   Effects of standard training in the use of closed-circuit televisions in visually impaired adults: design of a training protocol and a randomized controlled trial [J].
Burggraaff, Marloes C. ;
van Nispen, Ruth M. A. ;
Melis-Dankers, Bart J. M. ;
van Rens, Ger H. M. B. .
BMC HEALTH SERVICES RESEARCH, 2010, 10
[7]  
CHARMAN WN, 1985, OPHTHAL PHYSL OPT, V5, P211, DOI 10.1111/j.1475-1313.1985.tb00658.x
[8]   Nonlinear mixed-effects modeling of MNREAD data [J].
Cheung, Sing-Hang ;
Kallie, Christopher S. ;
Legge, Gordon E. ;
Cheong, Allen M. Y. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (02) :828-835
[9]  
de Boer M R, 2005, Ned Tijdschr Geneeskd, V149, P1502
[10]   Evidence-based guidelines on the referral of visually impaired persons to low vision services [J].
de Boer, MR ;
Langelaan, M ;
Jansonius, NM ;
van Rens, GHMB .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2005, 15 (03) :400-406