Measuring log Kow coefficients of neutral species of perfluoroalkyl carboxylic acids using reversed-phase high-performance liquid chromatography

被引:19
|
作者
Xiang, Qian [1 ]
Shan, Guoqiang [1 ]
Wu, Wei [1 ]
Jin, Hangbiao [1 ]
Zhu, Lingyan [1 ]
机构
[1] Nankai Univ, Coll Environm Sci & Engn, Key Lab Pollut Proc & Environm Criteria, Minist Educ,Tianjin Key Lab Environm Remediat & P, Tianjin 300350, Peoples R China
关键词
Perfluoroalkyl carboxylic acids; Reversed-phase high-performance liquid chromatography; N-octanol/water partition coefficient; pH; pK(a)-pH conversion; WATER PARTITION-COEFFICIENTS; GRADIENT RP-HPLC; POLYFLUOROALKYL SUBSTANCES; PHYSICOCHEMICAL PROPERTIES; EMPIRICAL CORRELATION; STATIONARY PHASES; MASS-SPECTROMETRY; HYDROPHOBICITY; RETENTION; PREDICTION;
D O I
10.1016/j.envpol.2018.08.009
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Accurate measuring n-octanol/water partition coefficients (log K-ow) of perfluoroalkyl carboxylic acids (PFCAs) using experimental approach has been proven to be very difficult due to their special properties. The ionizable carboxyl groups in PFCAs make their log K-ow dependent on pH. In this study, the log K-ow values of neutral species of PFCAs (C-4 <= n <= 14) were measured based on reversed-phase high-performance liquid chromatography (RP-HPLC) with the mobile phase pH varying in the range of 1.09-5.00. The relationship between log K-ow and retention times was established using some reference compounds (including agrochemicals, polycyclic aromatic hydrocarbons) with known log K-ow values, and then validated with alkyl fatty acids, which have similar chemical structures as PFCAs. The apparent log K-ow (i.e., log D-ow) of the C4-14 PFCAs were calculated based on their retention times using the established model, and they displayed a negative linear relationship with the mobile phase pH in the range of 1.09-4.00. Consequently, the log D-ow values were converted to the corresponding log K-ow values (1.05-7.19) based on the relationship of log D-ow = log K-ow + pK(a) - pH. The log K-ow increased with perfluorinated carbon chain length with a greater rate for C-4 to C-5 PFCAs than for C5-14 PFCAs. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1283 / 1290
页数:8
相关论文
共 50 条
  • [21] Reversed-phase high-performance liquid chromatographic separations of tocopherols
    Abidi, SL
    Mounts, TL
    JOURNAL OF CHROMATOGRAPHY A, 1997, 782 (01) : 25 - 32
  • [22] Direct determination of lanthanides in simulated irradiated thoria fuels using reversed-phase high-performance liquid chromatography
    Jaison, P. G.
    Raut, Narendra M.
    Aggarwal, Suresh K.
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1122 (1-2) : 47 - 53
  • [23] A rapid analytical method of major milk proteins by reversed-phase high-performance liquid chromatography
    Ma, Lu
    Yang, Yongxin
    Chen, Jingting
    Wang, Jiaqi
    Bu, Dengpan
    ANIMAL SCIENCE JOURNAL, 2017, 88 (10) : 1623 - 1628
  • [24] Analysis of Grape Proteins from Wines by Perfusion Reversed-Phase High-Performance Liquid Chromatography
    Rodriguez-Nogales, Jose M.
    Vila-Crespo, Josefina
    Fernandez-Fernandez, Encarnacion
    FOOD ANALYTICAL METHODS, 2013, 6 (04) : 1234 - 1243
  • [25] UNSUPERVISED CLASSIFICATION OF CHROMATOGRAPHIC COLUMNS IN MICELLAR AND CONVENTIONAL REVERSED-PHASE HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY
    Melnikov, A. U.
    Boichenko, A. P.
    Kulikov, A. U.
    Galat, M. N.
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2014, 37 (07) : 1016 - 1031
  • [26] Native and modified alumina, titania and zirconia in normal and reversed-phase high-performance liquid chromatography
    Kurganov, A
    Trudinger, U
    Isaeva, T
    Unger, K
    CHROMATOGRAPHIA, 1996, 42 (3-4) : 217 - 222
  • [27] Monitoring aged reversed-phase high performance liquid chromatography columns
    Bolck, A
    Smilde, AK
    Bruins, CHP
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1999, 46 (01) : 1 - 12
  • [28] Impurity profiling of drug candidates: Analytical strategies using reversed-phase and mixed-mode high-performance liquid chromatography methods
    Lemasson, Elise
    Bertin, Sophie
    Hennig, Philippe
    Lesellier, Eric
    West, Caroline
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1535 : 101 - 113
  • [29] Feasibility of using gravimetry to measure excess adsorption effects of a binary solvent system in a reversed-phase high-performance liquid chromatography column
    Loeser, Eric
    Babiak, Stanislaw
    Liu, Zhaoxia
    Girgis, Michael
    Drumm, Patrick
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (18) : 3927 - 3932
  • [30] A comparison and column selection of Hydrophilic Interaction Liquid Chromatography and Reversed-Phase High-Performance Liquid Chromatography for detection of DNA methylation
    Rastegar, Leila
    Mighani, Hossein
    Ghassempour, Alireza
    ANALYTICAL BIOCHEMISTRY, 2018, 557 : 123 - 130