Reference-Based Linear Curve Fitting for Bolus Arrival Time Estimation in 4D MRA and MR Perfusion-Weighted Image Sequences

被引:23
作者
Forkert, Nils Daniel [1 ]
Fiehler, Jens [2 ]
Ries, Thorsten [2 ]
Illies, Till [2 ]
Moeller, Dietmar [3 ]
Handels, Heinz [4 ]
Saering, Dennis [1 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, Dept Med Informat, D-20246 Hamburg, Germany
[2] Univ Med Ctr Hamburg Eppendorf, Dept Diagnost & Intervent Neuroradiol, D-20246 Hamburg, Germany
[3] Univ Hamburg, Dept Comp Engn, Fac Math Informat & Nat Sci, Hamburg, Germany
[4] Univ Lubeck, Inst Med Informat, Lubeck, Germany
关键词
magnetic resonance angiography; indicator dilution techniques; hemodynamics; curve fitting; computer simulation; INDICATOR-DILUTION CURVES; GAMMA-VARIATE; BLOOD-FLOW; ARTERIOVENOUS-MALFORMATIONS; ANGIOGRAPHY; VOLUME; FITS;
D O I
10.1002/mrm.22583
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The bolus arrival time ( BAT) based on an indicator dilution curve is an important hemodynamic parameter. As the direct estimation of this parameter is generally problematic, various parametric models have been proposed that describe typical physiological shapes of indicator dilution curves, but it remains unclear which model describes the real physiological background. This article presents a method that indirectly incorporates physiological information derived from the data available. For this, a patient-specific hemodynamic reference curve is extracted, and the corresponding reference BAT is determined. To estimate a BAT for a given signal curve, the reference curve is fitted linearly to the signal curve. The parameters of the fitting process are then used to transfer the reference BAT to the signal curve. The validation of the method proposed based on Monte Carlo simulations showed that the approach presented is capable of improving the BAT estimation precision compared with standard BAT estimation methods by up to 59% while at the same time reduces the computation time. A major benefit of the method proposed is that no assumption about the underlying distribution of indicator dilution has to be made, as it is implicitly modeled in the reference curve. Magn Reson Med 65:289-294, 2011. (C) 2010 Wiley-Liss, Inc.
引用
收藏
页码:289 / 294
页数:6
相关论文
共 20 条
[1]   The shape of indicator dilution curves used for cardiac output measurement in man [J].
Band, DM ;
Linton, RAF ;
OBrien, TK ;
Jonas, MM ;
Linton, NWF .
JOURNAL OF PHYSIOLOGY-LONDON, 1997, 498 (01) :225-229
[2]   Accuracy of gamma-variate fits to concentration-time curves from dynamic susceptibility-contrast enhanced MRI: Influence of time resolution, maximal signal drop and signal-to-noise [J].
Benner, T ;
Heiland, S ;
Erb, G ;
Forsting, M ;
Sartor, K .
MAGNETIC RESONANCE IMAGING, 1997, 15 (03) :307-317
[3]   PHYSIOLOGICAL INTERPRETATION OF THE SKEWNESS OF INDICATOR-DILUTION CURVES - THEORETICAL CONSIDERATIONS AND A PRACTICAL APPLICATION [J].
BOGAARD, JM ;
SMITH, SJ ;
VERSPRILLE, A ;
WISE, ME ;
HAGEMEIJER, F .
BASIC RESEARCH IN CARDIOLOGY, 1984, 79 (04) :479-493
[4]   An automatic approach for estimating bolus arrival time in dynamic contrast MRI using piecewise continuous regression models [J].
Cheong, LH ;
Koh, TS ;
Hou, Z .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (05) :N83-N88
[5]   Territorial and Microvascular Perfusion Impairment in Brain Arteriovenous Malformations [J].
Fiehler, J. ;
Illies, T. ;
Piening, M. ;
Saering, D. ;
Forkert, N. ;
Regelsberger, J. ;
Grzyska, U. ;
Handels, H. ;
Byrne, J. V. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (02) :356-361
[6]  
Fink C, 2005, INVEST RADIOL, V40, P40
[7]  
Forkert ND, 2009, MED IMAGING 2009 VIS, P7261
[8]   A theoretical model of cerebral hemodynamics: Application to the study of arteriovenous malformations [J].
Gao, EZ ;
Young, WL ;
Ornstein, E ;
PileSpellman, J ;
Ma, QY .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1997, 17 (08) :905-918
[9]   Erroneous and inappropriate use of gamma fits to tracer-dilution curves in magnetic resonance imaging and nuclear medicine [J].
Li, XF ;
Tian, J ;
Millard, RK .
MAGNETIC RESONANCE IMAGING, 2003, 21 (09) :1095-1096
[10]  
Linton RAF, 1995, CARDIOVASC RES, V30, P930, DOI 10.1016/0008-6363(95)00146-8