A full numerical model for the installation analysis of suction caissons in sand

被引:18
作者
Harireche, Ouahid [1 ]
Naqash, Muhammad Tayyab [1 ]
Farooq, Qazi Umar [1 ]
机构
[1] Islamic Univ Madinah, Dept Civil Engn, Fac Engn, Jennah, Saudi Arabia
关键词
Suction caisson; Installation feasibility; Pumping rate; Soil resistance; Piping; Full numerical model; PENETRATION RESISTANCE; BUCKET FOUNDATION; DESIGN PROCEDURES; SEEPAGE FIELD; OFFSHORE; CAPACITY; PLATFORM; CLAY;
D O I
10.1016/j.oceaneng.2021.109173
中图分类号
U6 [水路运输]; P75 [海洋工程];
学科分类号
0814 ; 081505 ; 0824 ; 082401 ;
摘要
Safe installation of suction caissons requires a reliable preliminary study where soil resistance and other soil conditions are predicted with good accuracy. Past studies did not address the full problem when modelling the installation procedure of suction caissons in sand. Suction was prescribed at the mudline and soil resistance was predicted based on soil properties and the resulting seepage profile around the caisson wall. Suction magnitude was assumed to overcome soil resistance, limiting its magnitude to avoid critical conditions such as piping. Most of these studies did not address other important parameters such as pumping rate and water depth. This paper addresses the following points: Feasibility of the installation depends on the water depth and hence, this must be specified as part of the installation design. Suction magnitude in excess to the initial hydrostatic pressure corresponds to a certain pumping rate, which is the parameter to control for a safe installation. A full numerical model is proposed in this paper to consider a prescribed pumping rate at the center of the caisson lid and the resulting flow inside the caisson cavity. The model was implemented in COMSOL Multiphysics and used to perform simulations of suction assisted installation in sand. Prescribed pumping rates have been investigated in conjunction with mobilized soil resistance, critical piping, water depth and available driving pressure.
引用
收藏
页数:14
相关论文
共 43 条
  • [1] Allersma HGB, 2003, BGA INTERNATIONAL CONFERENCE ON FOUNDATIONS: INNOVATIONS, OBSERVATIONS, DESIGN AND PRACTICE, P91
  • [2] Allersma HGB, 1999, INT OFFSHORE POLAR E, P711
  • [3] A standard formulation for the installation of suction caissons in sand
    Alluqmani, Ayed Eid
    Naqash, Muhammad Tayyab
    Harireche, Ouahid
    [J]. JOURNAL OF OCEAN ENGINEERING AND SCIENCE, 2019, 4 (04) : 395 - 405
  • [4] Penetration resistance of offshore skirted foundations and anchors in dense sand
    Andersen, Knut H.
    Jostad, Hans Petter
    Dyvik, Rune
    [J]. JOURNAL OF GEOTECHNICAL AND GEOENVIRONMENTAL ENGINEERING, 2008, 134 (01) : 106 - 116
  • [5] [Anonymous], 2004, 23 INT C OFFSHORE ME
  • [6] [Anonymous], 1995, OFFSH TECHN C HOUST
  • [7] Bang S, 1999, 11 AS REG C SOIL MEC 11 AS REG C SOIL MEC, P235
  • [8] Suction caissons in dense sand, part I: installation, limiting capacity and drainage
    Bienen, B.
    Klinkvort, R. T.
    O'Loughlin, C. D.
    Zhu, F.
    Byrne, B. W.
    [J]. GEOTECHNIQUE, 2018, 68 (11): : 937 - 952
  • [9] Bienen B, 2017, P 8 OFFSH SIT INV GE, P1
  • [10] Byrne B., 2002, Wind Engineering, V26, P145, DOI 10.1260/030952402762056063