Automated generation of a four-dimensional model of the liver using warping and mutual information

被引:55
作者
Brock, KM [1 ]
Balter, JM
Dawson, LA
Kessler, ML
Meyer, CR
机构
[1] Univ Michigan, Hlth Syst, Dept Radiat Oncol, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Hlth Syst, Dept Radiol, Ann Arbor, MI 48109 USA
关键词
deformation; mutual information; warping; liver radiotherapy;
D O I
10.1118/1.1576781
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The use of mutual information (MI) based alignment to map changes in liver shape and position from exhale to inhale was investigated. Inhale and exhale CT scans were obtained with intravenous contrast for six patients. MI based alignment using thin-plate spine (TPS) warping was performed between each inhale and exhale image set. An expert radiation oncologist identified corresponding vessel bifurcations on the exhale and inhale CT image and the transformation for identified points was determined. This transformation was then used to determine the accuracy of the MI based alignment. The reproducibility of the vessel bifurcation identification was measured through repeat blinded vessel bifurcation identification. Reproducibility [standard deviation (SD)] in the L/R, A/P, and I/S directions was 0.11, 0.09, and 0.14 cm, respectively. The average absolute difference between the transformation obtained using MI based alignment and the vessel bifurcation in the L/R, A/P, and I/S directions was 0.13 cm (SD = 0.10 cm), 0.15 cm (SD = 0.12 cm), and 0.15 cm (SD-0.14 cm), respectively. These values are comparable to the reproducibility of bifurcation identification, indicating that MI based alignment using TPS warping is accurate to within measurement error and is a reliable tool to aid in describing deformation that the liver undergoes from the exhale to inhale state. (C) 2003 American Association of Physicists in Medicine.
引用
收藏
页码:1128 / 1133
页数:6
相关论文
共 17 条
  • [2] Inclusion of organ deformation in dose calculations
    Brock, KK
    McShan, DL
    Ten Haken, RK
    Hollister, SJ
    Dawson, LA
    Balter, JM
    [J]. MEDICAL PHYSICS, 2003, 30 (03) : 290 - 295
  • [3] Technical note: Creating a four-dimensional model of the liver using finite element analysis
    Brock, KK
    Hollister, SJ
    Dawson, LA
    Balter, JM
    [J]. MEDICAL PHYSICS, 2002, 29 (07) : 1403 - 1405
  • [4] Comparison of rigid and elastic matching of dynamic magnetic resonance mammographic images by mutual information
    Brückner, T
    Lucht, R
    Brix, G
    [J]. MEDICAL PHYSICS, 2000, 27 (10) : 2456 - 2461
  • [5] [MoO2(acac)2], a versatile precursor for diazenido- and hydrazido-complexes
    Carrillo, D
    [J]. COMPTES RENDUS DE L ACADEMIE DES SCIENCES SERIE II FASCICULE C-CHIMIE, 2000, 3 (03): : 175 - 181
  • [6] A feasibility study of mutual information based setup error estimation for radiotherapy
    Kim, J
    Fessler, JA
    Lam, KL
    Balter, JM
    Ten Haken, RK
    [J]. MEDICAL PHYSICS, 2001, 28 (12) : 2507 - 2517
  • [7] Multimodality image registration by maximization of mutual information
    Maes, F
    Collignon, A
    Vandermeulen, D
    Marchal, G
    Suetens, P
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (02) : 187 - 198
  • [8] Meyer C R, 1997, Med Image Anal, V1, P195, DOI 10.1016/S1361-8415(97)85010-4
  • [9] MEYER CR, IN PRESS IEEE T MED
  • [10] PARK H, IN PRESS IEEE T MED