Comparison of reliability between uterocervical angle and cervical length measurements by various experienced operators using transvaginal ultrasound

被引:7
|
作者
Pruksanusak, Ninlapa [1 ]
Sawaddisan, Rapphon [1 ]
Kor-Anantakul, Ounjai [1 ]
Suntharasaj, Thitima [1 ]
Suwanrath, Chitkasaem [1 ]
Geater, Alan [2 ]
机构
[1] Prince Songkla Univ, Fac Med, Dept Obstet & Gynecol, Hat Yai, Songkhla, Thailand
[2] Prince Songkla Univ, Fac Med, Epidemiol Unit, Hat Yai, Songkhla, Thailand
关键词
Cervical length; reliability; uterocervical angle; PRETERM BIRTH; RISK; WOMEN; 2ND-TRIMESTER; PREDICTION; HISTORY;
D O I
10.1080/14767058.2018.1519542
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Purpose: To compare the reliability between uterocervical angle (UCA) and cervical length (CL) measurements by various experienced operators. Methods: Transvaginal ultrasonographies (TVS) were performed in 102 pregnant women between 16 degrees(/7)-24 degrees(/7) gestational weeks by different levels of experienced operators. For both CL and UCA measurements, intraobserver variability was assessed for each operator by examining the range between maximum and minimum measurements in each participant, compared to the mean of all three measurements. Interobserver variabilities were explored using Bland-Altman analysis. Intraclass correlation coefficients were used for both intraobserver and interobserver reliability. Results: For intraobserver variability of the UCA, the ranges between maximum and minimum UCA measurements in operator 1 and 3 were 1.5o-34o and 2o-36o (n = 51), and in operators 2 and 3 were 0o-61o and 1o-25o (n = 51). Intraclass correlation coefficients (ICC) for intraobserver reliability were 0.90 for operator 1, 0.67 for operator 2 and 0.93 for operator 3. For interobserver variability of the UCA, the limits of agreement for mean UCA were -37.53o-38.41o and -36.27o-26.17o, and for maximum UCA were -39.47o-41.38o and -44.24o-22.9o in comparisons between operators 1 and 3, and operator 2 and 3, respectively. Intraclass correlation coefficients for mean UCA were 0.73 and 0.74, and for maximum UCA were 0.71 and 0.67 in comparisons between operators 1 and 3, and operator 2 and 3, respectively. Conclusions: The UCA measurements had a higher intra- and interobserver reliabilities than the CL measurements.
引用
收藏
页码:1419 / 1426
页数:8
相关论文
共 20 条
  • [11] Cervical length assessment in twin pregnancies using transvaginal ultrasound
    Ong, S
    Smith, A
    Smith, N
    Campbell, D
    Wilson, A
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2000, 79 (10) : 851 - 853
  • [12] Transperineal Ultrasound to Measure Cervical Length of Pregnant Women in General and in Particular with Cervical Insufficiency - A Comparison of Transabdominal and Transperineal Ultrasound as Alternatives to Transvaginal Ultrasound
    Larscheid, P.
    Maass, N.
    Kennes, L. N.
    Najjari, L.
    ULTRASCHALL IN DER MEDIZIN, 2015, 36 (01): : 59 - 64
  • [13] Comparison of the POP-Q examination, transvaginal ultrasound, and direct anatomic measurement of cervical length
    Dancz, Christina E.
    Werth, Lisa
    Sun, Vanessa
    Lee, Sandy
    Walker, Daphne
    Oezel, Beguem
    INTERNATIONAL UROGYNECOLOGY JOURNAL, 2014, 25 (04) : 457 - 464
  • [14] The reliability of transabdominal cervical length measurement in a low-risk obstetric population: Comparison with transvaginal measurement
    Peng, Cheng-Ran
    Chen, Chie-Pein
    Wang, Kuo-Gon
    Wang, Liang-Kai
    Chen, Chen-Yu
    Chen, Yi-Yung
    TAIWANESE JOURNAL OF OBSTETRICS & GYNECOLOGY, 2015, 54 (02): : 167 - 171
  • [15] Reliability of the sonographic evaluation for cervical length and elastography with pelvic parameters in term pregnancy by experienced operators with varying levels of experience
    Sawaddisan, Rapphon
    Khwankaew, Noppasin
    Pruksanusak, Ninlapa
    Suntharasaj, Thitima
    Suwanrath, Chikasaem
    Pranpanus, Savitree
    Petpichetchian, Chusana
    Suksai, Manaphat
    Chainarong, Natthicha
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2024, 166 (01) : 333 - 342
  • [16] Comparison of the POP-Q examination, transvaginal ultrasound, and direct anatomic measurement of cervical length
    Christina E. Dancz
    Lisa Werth
    Vanessa Sun
    Sandy Lee
    Daphne Walker
    Begüm Özel
    International Urogynecology Journal, 2014, 25 : 457 - 464
  • [17] Transperineal versus transvaginal sonographic measurements of cervical length in pregnant women between 16 and 24 weeks of gestation
    Songserm, Vilasinee
    Komwilaisak, Ratana
    Saksiriwuttho, Piyamas
    Kongwattanakul, Kiattisak
    JOURNAL OF CLINICAL ULTRASOUND, 2019, 47 (07) : 389 - 393
  • [18] Measuring intraobserver and intermethod reliability of endometriotic cyst volumes: A comparison between MRI and 3D transvaginal ultrasound in endometriosis
    Bergwerff, Jasmijn
    Schreurs, Anneke M. F.
    Lier, Marit C., I
    van Waesberghe, Jan Hein T. M.
    van der Houwen, Lisette E. E.
    Mijatovic, Velja
    JOURNAL OF ENDOMETRIOSIS AND PELVIC PAIN DISORDERS, 2022, 14 (02) : 80 - 86
  • [19] Inter-Evaluator Reliability in Measurement of Muscle Thickness and Penance Angle through Ultrasound Evaluation: Comparison Study between an Expert and a Physical Therapist in Training
    Gallardo, Hugo Tapia
    del Sol, Mariano
    Gonzalez, Paul Medina
    Escobar-Cabello, Maximo
    Munoz-Cofre, Rodrigo
    Jerez-Mayorga, Daniel
    Lizama-Perez, Rodrigo
    INTERNATIONAL JOURNAL OF MORPHOLOGY, 2023, 41 (06): : 1846 - 1851
  • [20] Reliability of resting metabolic rate between and within day measurements using the Vyntus CPX system and comparison against predictive formulas
    Iraki, J.
    Paulsen, G.
    Garthe, I.
    Slater, G.
    Areta, J. L.
    NUTRITION AND HEALTH, 2023, 29 (01) : 107 - 114