Programmable Pulsed Magnetic Field System for Biological Applications

被引:20
作者
Novickij, Vitalij [1 ]
Grainys, Audrius [1 ]
Novickij, Jurij [1 ]
Lucinskis, Audrius [1 ]
机构
[1] Vilnius Gediminas Tech Univ, High Field Magnet Lab, LT-03227 Vilnius, Lithuania
关键词
Biological cells; biomedical electronics; electromagnetic systems; pulse power systems; ELECTROPORATION; DELIVERY;
D O I
10.1109/TMAG.2014.2323336
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, a pulsed magnetic field system developed for biological applications is presented. The proposed pulsed power setup generates repetitive controlled frequency and width square wave 0-4 kV electrical pulses and supports currents up to 1000 A. As a load, a solenoid-type inductor is used with integrated plastic cuvette for biological cells. Homogeneous repetitive microsecond range pulsed magnetic field up to 15 T inside the effective volume of the cuvette can be generated. The development process, the structure of the pulsed magnetic field setup, and the solutions implemented to achieve biomedical applicability are overviewed in this paper. The presented experimental results showing contactless permeabilization of biological cells in pulsed magnetic field have an excellent potential for the development of a new biomedical treatment technique and applicability of the setup.
引用
收藏
页数:4
相关论文
共 17 条
[1]   Exposure to High Static or Pulsed Magnetic Fields Does Not Affect Cellular Processes in the Yeast Saccharomyces cerevisiae [J].
Anton-Leberre, Veronique ;
Haanappel, Evert ;
Marsaud, Nathalie ;
Trouilh, Lidwine ;
Benbadis, Laurent ;
Boucherie, Helian ;
Massou, Sophie ;
Francois, Jean M. .
BIOELECTROMAGNETICS, 2010, 31 (01) :28-38
[2]  
Chengxiang L., 2011, IEEE T DIELECT EL IN, V18, P2083
[3]   A method for calculating the magnetic field produced by a coil of any shape [J].
García, A ;
Carrasco, JA ;
Soto, JF ;
Maganto, F ;
Morón, C .
SENSORS AND ACTUATORS A-PHYSICAL, 2001, 91 (1-2) :230-232
[4]  
Godlewska A, 2012, POL J ENVIRON STUD, V21, P615
[5]   Nonthermal Irreversible Electroporation: Fundamentals, Applications, and Challenges [J].
Golberg, Alexander ;
Yarmush, Martin L. .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (03) :707-714
[6]   Design and Analysis of a Novel Targeted Magnetic Fluid Hyperthermia System for Tumor Treatment [J].
Ho, S. L. ;
Jian, L. ;
Gong, W. ;
Fu, W. N. .
IEEE TRANSACTIONS ON MAGNETICS, 2012, 48 (11) :3262-3265
[7]   Contactless magneto-permeabilization for intracellular plasmid DNA delivery in vivo [J].
Kardos, Thomas J. ;
Rabussay, Dietmar P. .
HUMAN VACCINES & IMMUNOTHERAPEUTICS, 2012, 8 (11) :1707-1713
[8]  
Khan A. B., 2011, INFECT DESEASES CLIN, V19, P299
[9]   The Development of High Performance Pulsed Magnets of the Prototype Facility of WHMFC [J].
Li, L. ;
Peng, T. ;
Ding, H. ;
Han, X. ;
Ding, T. ;
Qiu, L. ;
Lv, Y. ;
Song, Y. ;
Duan, X. ;
Herlach, F. ;
Pan, Y. .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2010, 20 (03) :676-679
[10]   Microsecond Pulsed Magnetic Field Improves Efficacy of Antifungal Agents on Pathogenic Microorganisms [J].
Novickij, Vitalij ;
Grainys, Audrius ;
Svediene, Jurgita ;
Markovskaja, Svetlana ;
Paskevicius, Algimantas ;
Novickij, Jurij .
BIOELECTROMAGNETICS, 2014, 35 (05) :347-353