Blood Flow Measurement using Digital Subtraction Angiography for Assessing Hemodialysis Access Function

被引:4
作者
Koirala, Nischal [1 ,2 ]
Setser, Randolph M. [3 ]
Bullen, Jennifer [4 ]
McLennan, Gordon [2 ]
机构
[1] Cleveland State Univ, Dept Chem & Biomed Engn, Cleveland, OH 44115 USA
[2] Cleveland Clin, Dept Biomed Engn, Cleveland, OH 44106 USA
[3] Siemens Med Solut USA Inc, Cleveland, OH USA
[4] Cleveland Clin, Dept Quantitat Hlth Sci, Cleveland, OH 44106 USA
来源
MEDICAL IMAGING 2017: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING | 2017年 / 10137卷
关键词
Blood flow; bolus tracking algorithm; cross correlation; digital subtraction angiography; flow phantom; hemodialysis access; indicator-dilution principle; thermodilution; DOPPLER ULTRASOUND; VELOCITY; QUANTIFICATION; CONTRAST; VALIDATION; ARTERIES;
D O I
10.1117/12.2253929
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Blood flow rate is a critical parameter for diagnosing dialysis access function during fistulography where a flow rate of 600 ml/min in arteriovenous graft or 400-500 ml/min in arteriovenous fistula is considered the clinical threshold for fully functioning access. In this study, a flow rate computational model for calculating intra-access flow to evaluate dialysis access patency was developed and validated in an in vitro set up using digital subtraction angiography. Flow rates were computed by tracking the bolus through two regions of interest using cross correlation (XCOR) and mean arrival time (MAT) algorithms, and correlated versus an in-line transonic flow meter measurement. The mean difference (mean. standard deviation) between XCOR and in-line flow measurements for in vitro setup at 3, 6, 7.5 and 10 frames/s was 118 +/- 63; 37 +/- 59; 31 +/- 31; and 46.+/- 57 ml/min respectively while for MAT method it was 86 +/- 56; 57 +/- 72; 35 +/- 85; and 19 +/- 129 ml/min respectively. The result of this investigation will be helpful for selecting candidate algorithms while blood flow computational tool is developed for clinical application.
引用
收藏
页数:15
相关论文
共 50 条
[21]   Assessing the reliability of pulsatility in four-dimensional digital subtraction angiography time concentration curves [J].
Xu, Jimmy ;
Shaughnessy, Gabe ;
Schafer, Sebastian ;
Jiang, Jingfeng ;
Mistretta, Charles ;
Strother, Charles M. .
BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2018, 4 (03)
[22]   Peri-Therapeutic Quantitative Flow Analysis of Endovascular Revascularization for Ischemic Stroke Patients on Digital Subtraction Angiography [J].
Yang, Shih-Neng ;
Lin, Yu-Yi ;
Ho, Tsung-Jung ;
Cheng, Shi-Yann ;
Chiou, Yu-Rou ;
Liao, Chun-Han ;
Zhang, Geoffrey G. ;
Huang, Tzung-Chi .
JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2018, 38 (03) :387-395
[23]   Regional volumetric coronary blood flow measurement by digital angiography: In vivo validation [J].
Molloi, S ;
Zhou, YF ;
Kassab, GS .
ACADEMIC RADIOLOGY, 2004, 11 (07) :757-766
[24]   In-Room Direct Nidal Flow Measurement by Digital Subtraction Angiography to Estimate Hemorrhage Risk in Brain Arteriovenous Malformations: A Pilot Study [J].
Chen, Ko-Kung ;
Yang, Huai-che ;
Lee, Cheng-Chia ;
Lin, Chun-Fu ;
Chu, Wei-Fa ;
Hsu, Sanford P. C. ;
Chang, Feng-Chi ;
Su, I-Chang ;
Chiou, Hong-Jen ;
Lin, Chung-Jung .
STROKE-VASCULAR AND INTERVENTIONAL NEUROLOGY, 2023, 3 (03)
[25]   Comparison of extracranial artery stenosis and cerebral blood flow, assessed by quantitative magnetic resonance, using digital subtraction angiography as the reference standard [J].
Cai, Jingjing ;
Wu, Dan ;
Mo, Yongqian ;
Wang, Anxin ;
Hu, Shiyu ;
Ren, Lijie .
MEDICINE, 2016, 95 (46)
[26]   Phenylephrine-modulated cardiopulmonary blood flow measured with use of X-ray digital subtraction angiography [J].
Lin, MingDe ;
Qi, Yi ;
Chen, Antonia F. ;
Badea, Cristian T. ;
Johnson, G. Allan .
JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 2011, 64 (02) :180-186
[27]   INTRAVENOUS DIGITAL SUBTRACTION ANGIOGRAPHY FOR THE EVALUATION OF RENAL-ARTERY BLOOD-FLOW FOLLOWING THE REMOVAL OF A NEUROBLASTOMA [J].
YAMAGIWA, I ;
OBATA, K ;
SAITO, H ;
WASHIO, M .
SURGERY TODAY-THE JAPANESE JOURNAL OF SURGERY, 1994, 24 (11) :973-977
[28]   Motion compensation in digital subtraction angiography using graphics hardware [J].
Deuerling-Zheng, Yu ;
Lell, Michael ;
Galant, Adam ;
Hornegger, Joachim .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2006, 30 (05) :279-289
[29]   The measurement of internal carotid artery stenosis: Comparison of duplex with digital subtraction angiography [J].
Padayachee, TS ;
Cox, TCS ;
Modaresi, KB ;
Colchester, ACF ;
Taylor, PR .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1997, 13 (02) :180-185
[30]   Contrast Time-Density Time on Digital Subtraction Angiography Correlates With Cerebral Arteriovenous Malformation Flow Measured by Quantitative Magnetic Resonance Angiography, Angioarchitecture, and Hemorrhage [J].
Brunozzi, Denise ;
Hussein, Ahmed E. ;
Shakur, Sophia F. ;
Linninger, Andreas ;
Hsu, Chih-Yang ;
Charbel, Fady T. ;
Alaraj, Ali .
NEUROSURGERY, 2018, 83 (02) :210-216