Sizing of a recuperative supercritical CO2 Brayton cycle as power conversion system for DEMO fusion reactor based on Dual Coolant Lithium Lead blanket

被引:18
作者
Ignacio Linares, Jose [1 ]
Arenas, Eva [1 ]
Cantizano, Alexis [1 ]
Porras, Jose [1 ]
Yolanda Moratilla, Beatriz [1 ]
Carmona, Mar [1 ]
Batet, Lluis [2 ]
机构
[1] Comillas Pontificial Univ, Alberto Aguilera 25, Madrid 28015, Spain
[2] Catalonia Polytech Univ, Diagonal 647, Barcelona 08028, Spain
关键词
Balance of plant; Fusion power; Supercritical CO2 Brayton cycle; DCLL; DEMO; THERMAL-ENERGY STORAGE; PERFORMANCE; HELIUM; PLANT; OPTIMIZATION; LAYOUTS; DESIGN; S-CO2; FLUID;
D O I
10.1016/j.fusengdes.2018.06.026
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A modified recuperative supercritical CO2 cycle for DEMO fusion reactor is analysed. A layout with just one recuperator is used, because of the relatively low temperature of the breeding blanket coolants. The proposed cycle is able to integrate several thermal sources with different temperature ranges and includes two kinds of thermal energy storage to overcome the pulse operation: a two-tank molten salt storage and a concrete storage. The design point is obtained using the Engineering Equation Solver (EES) environment, which allows to use pure substance models for CO2, helium and water. Once the design point is calculated, the sizing of pipes, heat exchangers, turbomachines and energy storage systems has been performed in order to obtain a preliminary estimation of the layout and its complexity. So, the power conversion system has been split into four equal parts in order to use commercial pipe diameters. Even though Printed Circuit Heat Exchangers (PCHE) have been used, extremely large sizes have been obtained, especially for the HTR recuperator. These sizes contrast with the small values obtained for the turbomachines, whose preliminary design has been carried out, using the AXIAL (TM). meanline design software. In addition, the two largest heat exchangers are divided into serial and parallel configurations when assessing the allocation of the components of the power conversion system to reduce the footprint. An average electric efficiency (including pulse and dwell period) of 28.25% has been reached. The required mass of molten salt per each power conversion subsystem is 2568 t, while the mass of concrete is 833 t. Regarding the footprint, 85 x 170 m(2) are required for each power conversion subsystem, including the storage systems.
引用
收藏
页码:79 / 91
页数:13
相关论文
共 78 条
[1]   REVIEW OF SUPERCRITICAL CO2 POWER CYCLE TECHNOLOGY AND CURRENT STATUS OF RESEARCH AND DEVELOPMENT [J].
Ahn, Yoonhan ;
Bae, Seong Jun ;
Kim, Minseok ;
Cho, Seong Kuk ;
Baik, Seungjoon ;
Lee, Jeong Ik ;
Cha, Jae Eun .
NUCLEAR ENGINEERING AND TECHNOLOGY, 2015, 47 (06) :647-661
[2]   Study of various Brayton cycle designs for small modular sodium-cooled fast reactor [J].
Ahn, Yoonhan ;
Lee, Jeong Ik .
NUCLEAR ENGINEERING AND DESIGN, 2014, 276 :128-141
[3]   Thermoeconomic analysis & optimization of the combined supercritical CO2 (carbon dioxide) recompression Brayton/organic Rankine cycle [J].
Akbari, Ata D. ;
Mahmoudi, Seyed M. S. .
ENERGY, 2014, 78 :501-512
[4]   CARBON DIOXIDE CONDENSATION CYCLES FOR POWER PRODUCTION [J].
ANGELINO, G .
JOURNAL OF ENGINEERING FOR POWER, 1968, 90 (03) :287-&
[5]  
[Anonymous], 2005, Gas Pipeline Hydraulics
[6]  
[Anonymous], 2007, B3112007 ASME
[7]  
[Anonymous], 2014, 201318 INT EN AG
[8]  
[Anonymous], 2010, CO2 PIPELINE INFRAST
[9]  
[Anonymous], 2015, SYST INT CONT MOLT S
[10]  
Ariu V, 2014, THESIS