Termination of long-lasting persistent versus short-lasting persistent and paroxysmal atrial fibrillation by ablation

被引:28
|
作者
Fiala, Martin [1 ]
Chovancik, Jan [1 ]
Nevralova, Renata [1 ]
Neuwirth, Radek [1 ]
Jiravsky, Otakar [1 ]
Januska, Jaroslav [1 ]
Branny, Marian [1 ]
机构
[1] Hosp Podlesi AS, Ctr Heart, Dept Cardiol, Trinec 73961, Czech Republic
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2008年 / 31卷 / 08期
关键词
atrial fibrillation; persistent; paroxysmal; termination; ablation;
D O I
10.1111/j.1540-8159.2008.01126.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Left atrial (LA) Structures for the maintenance of different atrial fibrillation (AF) forms are not uniform. The incidence, electrophysiological patterns, and LA sites of sinus rhythm (SR) restoration during ablation of different AF forms were evaluated. Methods: One hundred patients with long-lasting persistent AF were retrospectively compared to 35 patients with short-lasting persistent AF and 59 patients with a sustained episode of paroxysmal AF. All patients underwent a first ablation using a stepwise ablation approach with the endpoint of SR restoration by ablation. Results: SR was restored in 38%, 83%, and 97% of patients with long-lasting persistent, short-lasting persistent, and paroxysmal AF, respectively (P < 0.001 for long-lasting persistent vs paroxysmal AF; P = 0.02 for long-lasting persistent vs short-lasting persistent AF). When modes and sites of SR restoration were evaluated among the patients with long-lasting persistent, short-lasting persistent, and paroxysmal AF, SR was restored via conversion into LA tachycardia in 79%, 52%, and 4% of patients (P < 0.001 for long-lasting persistent vs paroxysmal AF); by the pulmonary vein encirclingin 8%,24%, and 93% patients (P < 0.001 for long-lasting persistent vs paroxysmal AF); and by ablation at the LA anterior wall or inside the coronary sinus in 66%, 45%, and 2% patients (P < 0.001 for long-lasting persistent and paroxysmal AF). During the 31 +/- 14 month follow-up since the first ablation, of the 50 patients with long-term SR maintenance (38 patients free of class I or III antiarrhythmic drugs), SR was restored by ablation in 29 (58%) patients versus nine (18%) patients out of 50 patients with unsuccessful clinical outcome (P = 0.009). Conclusion: Ablation of long-lasting persistent AF was characterized by more frequent failure to restore SR, and predominant conversion into LA tachycardia prior to SR restoration, and SR restoration by ablation outside the LA posterior wall. SR restoration by ablation was associated with better clinical outcome in these patients.
引用
收藏
页码:985 / 997
页数:13
相关论文
共 50 条
  • [41] Long-term outcomes after radiofrequency catheter ablation of paroxysmal and persistent atrial fibrillation
    Sinkovec, Matjaz
    Pernat, Andrej
    Jan, Matevz
    Antolic, Bor
    ZDRAVNISKI VESTNIK-SLOVENIAN MEDICAL JOURNAL, 2013, 82 (10): : 661 - 668
  • [42] Ganglionated plexi ablation for longstanding persistent atrial fibrillation
    Pokushalov, Evgeny
    Romanov, Alexander
    Artyomenko, Sergey
    Turov, Alex
    Shugayev, Pavel
    Shirokova, Natalya
    Katritsis, Demosthenes G.
    EUROPACE, 2010, 12 (03): : 342 - 346
  • [43] Clamping versus nonclamping thoracoscopic box ablation in long-standing persistent atrial fibrillation
    Harlaar, Niels
    Verberkmoes, Niels J.
    van der Voort, Pepijn H.
    Trines, Serge A.
    Verstraeten, Stefan E.
    Mertens, Bart J. A.
    Klautz, Robert J. M.
    Braun, Jerry
    van Brakel, Thomas J.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2020, 160 (02) : 399 - 405
  • [44] Long-Term Clinical Results of 2 Different Ablation Strategies in Patients With Paroxysmal and Persistent Atrial Fibrillation
    Gaita, Fiorenzo
    Caponi, Domenico
    Scaglione, Marco
    Montefusco, Antonio
    Corleto, Antonella
    Di Monte, Fernando
    Coin, Daniele
    Di Donna, Paolo
    Giustetto, Carla
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2008, 1 (04) : 269 - 275
  • [45] Catheter Ablation Improves Cardiac Function in Both Patients With Paroxysmal and Persistent Atrial Fibrillation
    Nakatani, Yosuke
    Sakamoto, Tamotsu
    Yamaguchi, Yoshiaki
    Tsujino, Yasushi
    Nishida, Kunihiro
    Kinugawa, Koichiro
    CIRCULATION, 2017, 136
  • [46] Hybrid Ablation Versus Repeated Catheter Ablation in Persistent Atrial Fibrillation
    van der Heijden, Claudia A. J.
    Weberndoerfer, Vanessa
    Vroomen, Mindy
    Luermans, Justin G.
    Chaldoupi, Sevasti-Maria
    Bidar, Elham
    Vernooy, Kevin
    Maessen, Jos G.
    Pison, Laurent
    van Kuijk, Sander M. J.
    La Meir, Mark
    Crijns, Harry J. G. M.
    Maesen, Bart
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2023, 9 (07) : 1013 - 1023
  • [47] Termination of Persistent Atrial Fibrillation During Left Atrial Mapping
    Tzou, Wendy S.
    Saghy, Laszlo
    Lin, David
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2011, 22 (10) : 1171 - 1173
  • [48] Impact of acute atrial fibrillation termination and prolongation of atrial fibrillation cycle length on the outcome of ablation of persistent atrial fibrillation: A substudy of the STAR AF II trial
    Kochhaeuser, Simon
    Jiang, Chen-Yang
    Betts, Timothy R.
    Chen, Jian
    Deisenhofer, Isabel
    Mantovan, Roberto
    Macle, Laurent
    Morillo, Carlos A.
    Haverkamp, Wilhelm
    Weerasooriya, Rukshen
    Albenque, Jean-Paul
    Nardi, Stefano
    Menardi, Endrj
    Novak, Paul
    Sanders, Prashanthan
    Verma, Atul
    HEART RHYTHM, 2017, 14 (04) : 476 - 483
  • [49] Long-Lasting Ventricular Fibrillation in Humans ECG Characteristics and Effect of Radiofrequency Ablation
    Maury, Philippe
    Duchateau, Josselin
    Rollin, Anne
    Hocini, Meleze
    Voglimacci-Stephanopoli, Quentin
    Monteil, Benjamin
    Sacher, Frederic
    Jais, Pierre
    Bernus, Olivier
    Mondoly, Pierre
    Delmas, Clement
    Haissaguerre, Michel
    Dubois, Remi
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2020, 13 (10) : 1157 - 1164
  • [50] Left Atrial Voltage during Atrial Fibrillation in Paroxysmal and Persistent Atrial Fibrillation Patients
    Fiala, Martin
    Wichterle, Dan
    Chovancik, Jan
    Bulkova, Veronika
    Wojnarova, Dorota
    Nevralova, Renata
    Januska, Jaroslav
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2010, 33 (05): : 541 - 548