Titanium Coating of the Boston Keratoprosthesis

被引:30
|
作者
Salvador-Culla, Borja [1 ,2 ,3 ]
Jeong, Kyung Jae [4 ]
Kolovou, Paraskevi Evi [1 ]
Chiang, Homer H. [2 ,3 ]
Chodosh, James [1 ]
Dohlman, Claes H. [1 ]
Kohane, Daniel S. [2 ]
机构
[1] Harvard Med Sch, Massachusetts Eye & Ear Infirm, Dept Ophthalmol, Boston, MA USA
[2] Harvard Med Sch, Lab Biomat & Drug Delivery, Dept Anesthesiol, Div Crit Care Med,Childrens Hosp Boston, Boston, MA USA
[3] MIT, David H Koch Inst Integrat Canc Res, 77 Massachusetts Ave, Cambridge, MA 02139 USA
[4] Univ New Hampshire, Dept Chem Engn, Durham, NH 03824 USA
来源
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY | 2016年 / 5卷 / 02期
关键词
keratoprosthesis; Boston Keratoprosthesis; artificial cornea; titanium coating; titanium oxide; titanium skirt; biointegration; corneal adhesion; titanium adhesion; OSTEOBLAST-LIKE CELLS; TYPE-1; KERATOPROSTHESIS; SURFACE-ROUGHNESS; HYDROXYAPATITE; MULTICENTER; ENDOPHTHALMITIS; IMPLANTATION; TOMOGRAPHY; RETENTION; EFFICACY;
D O I
10.1167/tvst.5.2.17
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: We tested the feasibility of using titanium to enhance adhesion of the Boston Keratoprosthesis (B-KPro), ultimately to decrease the risk of implant-associated complications. Methods: Cylindrical rods were made of poly(methyl methacrylate) (PMMA), PMMA coated with titanium dioxide (TiO2) over a layer of polydopamine (PMMA(TiO2)), smooth (Ti) and sandblasted (Ti-SB) titanium, and titanium treated with oxygen plasma (Ti-ox and Ti-SBox). Topography and surface chemistry were analyzed by scanning electron microscopy (SEM), atomic force microscopy (AFM), and X-ray photoelectron spectroscopy (XPS). Adhesion force between rods and porcine corneas was measured ex vivo. Titanium sleeves, smooth and sandblasted, were inserted around the stem of the B-KPro and implanted in rabbits. Tissue adhesion to the stem was assessed and compared to an unmodified B-Kpro after 1 month. Results: X-ray photoelectron spectroscopy demonstrated successful deposition of TiO2 on polydopamine-coated PMMA. Oxygen plasma treatment did not change the XPS spectra of titanium rods (Ti and Ti-SB), although it increased their hydrophilicity. The materials did not show cell toxicity. After 14 days of incubation, PMMA(TiO2), smooth titanium treated with oxygen plasma (Ti-ox), and sandblasted titanium rods (Ti-SB, Ti-SBox) showed significantly higher adhesion forces than PMMA ex vivo. In vivo, the use of a Ti-SB sleeve around the stem of the B-KPro induced a significant increase in tissue adhesion compared to a Ti sleeve or bare PMMA. Conclusions: Sandblasted titanium sleeves greatly enhanced adherence of the B-KPro to the rabbit cornea. This approach may improve adhesion with the donor cornea in humans as well. Translational Relevance: This approach may improve adhesion with donor corneas in humans.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Boston Keratoprosthesis
    Kwitko, Sergio
    Stolz, Andressa Prestes
    REVISTA BRASILEIRA DE OFTALMOLOGIA, 2012, 71 (06) : 403 - 406
  • [32] Outcomes of the Boston Keratoprosthesis in Jordan
    Shihadeh, Wisam A.
    Mohidat, Hasan M.
    MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2012, 19 (01) : 97 - 100
  • [33] Endophthalmitis in Boston keratoprosthesis: case series and review of literature
    Jay Chhablani
    Bhavik Panchal
    Taraparasad Das
    Avinash Pathegay
    Swapna R. Motukupally
    Rajeev Reddy Pappuru
    Sayan Basu
    Virender Sangwan
    International Ophthalmology, 2015, 35 : 673 - 678
  • [34] Anatomical survival and visual prognosis of Boston type I keratoprosthesis in challenging cases
    Fideliz de la Paz, Maria
    Stoiber, Josef
    Couto Nascimento, Valeria de Rezende
    Alvarez de Toledo, Juan
    Seyeddain, Orang
    Hitzl, Wolfgang
    Grabner, Guenther
    Barraquer, Rafael I.
    Michael, Ralph
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 252 (01) : 83 - 90
  • [35] Clinical Outcomes Using Oversized Back Plates in Type I Boston Keratoprosthesis
    Kaufman, Aaron R.
    Cruzat, Andrea
    Colby, Kathryn A.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2018, 44 (06): : 399 - 404
  • [36] Endophthalmitis in Boston keratoprosthesis: case series and review of literature
    Chhablani, Jay
    Panchal, Bhavik
    Das, Taraparasad
    Pathegay, Avinash
    Motukupally, Swapna R.
    Pappuru, Rajeev Reddy
    Basu, Sayan
    Sangwan, Virender
    INTERNATIONAL OPHTHALMOLOGY, 2015, 35 (05) : 673 - 678
  • [37] The Boston keratoprosthesis in the management of corneal blindness: Indications and limitations
    Stolowy, N.
    Callet, M.
    Beylerian, M.
    Hoffart, L.
    Yin, G. Ho Wang
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2018, 41 (07): : 642 - 649
  • [38] The Boston Keratoprosthesis Type I in Mucous Membrane Pemphigoid
    Palioura, Sotiria
    Kim, Bryan
    Dohlman, Claes H.
    Chodosh, James
    CORNEA, 2013, 32 (07) : 956 - 961
  • [39] The Boston keratoprosthesis 2014: a step in the evolution of artificial corneas
    Dohlman, Claes H.
    Cruzat, Andrea
    White, Michelle
    SPEKTRUM DER AUGENHEILKUNDE, 2014, 28 (06) : 226 - 233
  • [40] The Boston-Keratoprosthesis: an overview on the basis of own experience
    Neuhann, Thomas
    Koller, Barbara
    Neuhann, Irmingard
    SPEKTRUM DER AUGENHEILKUNDE, 2015, 29 (01) : 37 - 45