Reliability and accuracy in radiographic measurements of musculoskeletal tumors

被引:1
|
作者
Kellish, Alec S. [1 ]
Miskiel, Sandra [2 ]
Gaughan, John [2 ]
Barshay, Veniamin [3 ]
Kim, Tae W. [2 ]
Gutowski, Christina J. [2 ]
机构
[1] Thomas Jefferson Univ Hosp, Dept Orthopaed Surg, 925 Chestnut St,5th Floor, Philadelphia, PA 19107 USA
[2] Cooper Univ Hosp, Dept Orthopaed, Camden, NJ USA
[3] Cooper Univ Hosp, Dept Radiol, Camden, NJ USA
关键词
accuracy; musculoskeletal oncology; precision; radiographic measurements; sarcoma; INTRAOBSERVER VARIABILITY; INTEROBSERVER; ERROR; CT; VOLUMETRICS; RADIOLOGY; SIZE; BONE; MRI;
D O I
10.1002/jor.25197
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Tumor size and growth are important parameters when evaluating bone and soft tissue neoplasms. There are no reports comparing the intra- and interobserver reliability among physicians in their evaluation of musculoskeletal (MSK) tumor imaging. This study investigates the accuracy and precision of measurements made by orthopedic and radiology physicians in different stages of training. Blinded magnetic resonance imaging (MRI) scans from six patients, three soft tissue, and three bone tumors were selected: each case included an "old" and "new" scan that was performed at least 3 months apart. Fourteen participants were selected, representing varying levels of education and experience, including two of each of the following: medical students, orthopedic and radiology residents, oncology and nononcologic orthopedic attendings, and MSK and non-MSK radiology attendings. Participants compared the old and new studies, recording tumor size in the transverse, cranial-caudal, and anterior-posterior dimensions, and determined if the tumor was stable or unstable. The MRI's official report served as the "gold standard." Average intraobserver variability (|Trial 1 - Trial 2|/[(Trial 1 + Trial 2)/2])) in size measurements was 11.08% (0.00%-68.62%). The lowest variability was recorded by the MSK radiologist 1 (6.16%), and the greatest variability by Orthopedic Surgery Resident 1 (16.70%). Participants correctly determined stability 82% of the time (71%-100%). Only MSK radiologists correctly determined stability in over 90% of cases. There is considerable variability and inaccuracy in MRI-based measurements of MSK tumors. These findings motivate opportunities for improving MSK imaging education of radiology and orthopedic residents. Physicians ordering MRI scans should evaluate them themselves, instead of relying on the radiology report alone, to inform clinical decision-making.
引用
收藏
页码:1654 / 1660
页数:7
相关论文
共 50 条
  • [31] Management of musculoskeletal tumors during pregnancy: a retrospective study
    Postl, Lukas K.
    Gradl, Guntmar
    von Eisenhart-Rothe, Ruediger
    Toepfer, Andreas
    Pohlig, Florian
    Burgkart, Rainer
    Rechl, Hans
    Kirchhoff, Chlodwig
    BMC WOMENS HEALTH, 2015, 15
  • [32] Prereferral MRI Use in Patients with Musculoskeletal Tumors Is Not Excessive
    Martin, Christopher T.
    Morcuende, Jose
    Buckwalter, Joseph A.
    Miller, Benjamin J.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (11) : 3240 - 3245
  • [33] An update in musculoskeletal tumors: from quantitative imaging to radiomics
    Chianca, Vito
    Albano, Domenico
    Messina, Carmelo
    Vincenzo, Gabriele
    Rizzo, Stefania
    Del Grande, Filippo
    Sconfienza, Luca Maria
    RADIOLOGIA MEDICA, 2021, 126 (08): : 1095 - 1105
  • [34] HISTOPATHOLOGICAL STUDY ON BIOPSY TRACK IN MALIGNANT MUSCULOSKELETAL TUMORS
    Ribeiro, Marcelo Barbosa
    de Oliveira, Claudia Regina G. C. M.
    Filippi, Renee Zon
    Baptista, Andre Mathias
    Caiero, Marcelo Tadeu
    Saito, Carlos Fernando
    Barbosa do Nascimento, Sergio Antonio
    de Camargo, Olavo Pires
    ACTA ORTOPEDICA BRASILEIRA, 2009, 17 (05): : 279 - 281
  • [35] Accuracy and reliability of MRI vs. laboratory measurements in an ex vivo porcine model of arthritic cartilage loss
    Jaremko, Jacob L.
    Maciejewski, Conrad M.
    Cheng, Rita W. T.
    Ronsky, Janet L.
    Thompson, Richard B.
    Lambert, Robert G. W.
    Dhillon, Sukhvinder S.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (04) : 992 - 1000
  • [36] Accuracy and Reliability of Marker-Based Approaches to Scale the Pelvis, Thigh, and Shank Segments in Musculoskeletal Models
    Kainz, Hans
    Hoang, Hoa X.
    Stockton, Chris
    Boyd, Roslyn R.
    Lloyd, David G.
    Carty, Christopher P.
    JOURNAL OF APPLIED BIOMECHANICS, 2017, 33 (05) : 354 - 360
  • [37] Congenital musculoskeletal anomalies — key radiographic findings
    Kara G. Gill
    Pediatric Radiology, 2022, 52 : 777 - 785
  • [38] Congenital musculoskeletal anomalies - key radiographic findings
    Gill, Kara G.
    PEDIATRIC RADIOLOGY, 2022, 52 (04) : 777 - 785
  • [39] Reliability and validation of in vitro lumbar spine height measurements using musculoskeletal ultrasound: A preliminary investigation
    Sobczak, Stephane
    Dugailly, Pierre-Michel
    Gilbert, Kerry K.
    Hooper, Troy L.
    Sizer, Phillip S., Jr.
    James, C. Roger
    Poortmans, Bernard
    Matthijs, Omer C.
    Brismee, Jean-Michel
    JOURNAL OF BACK AND MUSCULOSKELETAL REHABILITATION, 2016, 29 (01) : 171 - 182
  • [40] Imaging neuroendocrine tumors: Characterizing the spectrum of radiographic findings
    Baghdadi, Azarakhsh
    Ghadimi, Maryam
    Mirpour, Sahar
    Hazhirkarzar, Bita
    Motaghi, Mina
    Pawlik, Timothy M.
    Kamel, Ihab R.
    SURGICAL ONCOLOGY-OXFORD, 2021, 37