Reliability and accuracy in radiographic measurements of musculoskeletal tumors

被引:1
|
作者
Kellish, Alec S. [1 ]
Miskiel, Sandra [2 ]
Gaughan, John [2 ]
Barshay, Veniamin [3 ]
Kim, Tae W. [2 ]
Gutowski, Christina J. [2 ]
机构
[1] Thomas Jefferson Univ Hosp, Dept Orthopaed Surg, 925 Chestnut St,5th Floor, Philadelphia, PA 19107 USA
[2] Cooper Univ Hosp, Dept Orthopaed, Camden, NJ USA
[3] Cooper Univ Hosp, Dept Radiol, Camden, NJ USA
关键词
accuracy; musculoskeletal oncology; precision; radiographic measurements; sarcoma; INTRAOBSERVER VARIABILITY; INTEROBSERVER; ERROR; CT; VOLUMETRICS; RADIOLOGY; SIZE; BONE; MRI;
D O I
10.1002/jor.25197
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Tumor size and growth are important parameters when evaluating bone and soft tissue neoplasms. There are no reports comparing the intra- and interobserver reliability among physicians in their evaluation of musculoskeletal (MSK) tumor imaging. This study investigates the accuracy and precision of measurements made by orthopedic and radiology physicians in different stages of training. Blinded magnetic resonance imaging (MRI) scans from six patients, three soft tissue, and three bone tumors were selected: each case included an "old" and "new" scan that was performed at least 3 months apart. Fourteen participants were selected, representing varying levels of education and experience, including two of each of the following: medical students, orthopedic and radiology residents, oncology and nononcologic orthopedic attendings, and MSK and non-MSK radiology attendings. Participants compared the old and new studies, recording tumor size in the transverse, cranial-caudal, and anterior-posterior dimensions, and determined if the tumor was stable or unstable. The MRI's official report served as the "gold standard." Average intraobserver variability (|Trial 1 - Trial 2|/[(Trial 1 + Trial 2)/2])) in size measurements was 11.08% (0.00%-68.62%). The lowest variability was recorded by the MSK radiologist 1 (6.16%), and the greatest variability by Orthopedic Surgery Resident 1 (16.70%). Participants correctly determined stability 82% of the time (71%-100%). Only MSK radiologists correctly determined stability in over 90% of cases. There is considerable variability and inaccuracy in MRI-based measurements of MSK tumors. These findings motivate opportunities for improving MSK imaging education of radiology and orthopedic residents. Physicians ordering MRI scans should evaluate them themselves, instead of relying on the radiology report alone, to inform clinical decision-making.
引用
收藏
页码:1654 / 1660
页数:7
相关论文
共 50 条
  • [21] Validity, reliability and reproducibility of plain radiographic measurements after total hip arthroplasty
    Sarwar S. Mahmood
    Bariq Al-Amiry
    Sebastian S. Mukka
    Saida Baea
    Arkan S. Sayed-Noor
    Skeletal Radiology, 2015, 44 : 345 - 351
  • [22] Validity, reliability and reproducibility of plain radiographic measurements after total hip arthroplasty
    Mahmood, Sarwar S.
    Al-Amiry, Bariq
    Mukka, Sebastian S.
    Baea, Saida
    Sayed-Noor, Arkan S.
    SKELETAL RADIOLOGY, 2015, 44 (03) : 345 - 351
  • [23] Image-guided Percutaneous Core Needle Biopsy of Musculoskeletal Tumors in Children
    Mitton, Bryan
    Seeger, Leanne L.
    Eckardt, Mark A.
    Motamedi, Kambiz
    Eilber, Fritz C.
    Nelson, Scott D.
    Eckardt, Jeffrey J.
    Federman, Noah
    JOURNAL OF PEDIATRIC HEMATOLOGY ONCOLOGY, 2014, 36 (05) : 337 - 341
  • [24] Radiomics in Musculoskeletal Tumors
    Brandenberger, Daniel
    White, Lawrence M.
    SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2024, 28 (01) : 49 - 61
  • [25] Poor accuracy of plain radiographic measurements of prosthetic migration and alignment in total ankle replacement
    Matthias Braito
    Michael Liebensteiner
    Dietmar Dammerer
    Martin Krismer
    Martin Pfurner
    Rainer Biedermann
    Journal of Orthopaedic Surgery and Research, 10
  • [26] Reliability and accuracy of straightforward measurements for liver volume determination in ultrasound and computed tomography compared to real volumetry
    Seppelt, D.
    Kromrey, M. L.
    Ittermann, T.
    Kolb, C.
    Haubold, A.
    Kampfrath, N.
    Fedders, D.
    Heiss, P.
    Hoberuck, S.
    Hoffmann, R. T.
    Kuehn, J. P.
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [27] Precision, accuracy, and reliability of hemoglobin assessment with use of capillary blood
    Morris, SS
    Ruel, MT
    Cohen, RJ
    Dewey, KG
    de la Brière, B
    Hassan, MN
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1999, 69 (06) : 1243 - 1248
  • [28] Footscan pressure insoles Accuracy and reliability of force and pressure measurements in running
    Low, D. C.
    Dixon, S. J.
    GAIT & POSTURE, 2010, 32 (04) : 664 - 666
  • [29] A Deep Learning Algorithm for Radiographic Measurements of the Hip in Adults-A Reliability and Agreement Study
    Jensen, Janni
    Graumann, Ole
    Overgaard, Soren
    Gerke, Oke
    Lundemann, Michael
    Haubro, Martin Haagen
    Varnum, Claus
    Bak, Lene
    Rasmussen, Janne
    Olsen, Lone B.
    Rasmussen, Benjamin S. B.
    DIAGNOSTICS, 2022, 12 (11)
  • [30] Poor accuracy of plain radiographic measurements of prosthetic migration and alignment in total ankle replacement
    Braito, Matthias
    Liebensteiner, Michael
    Dammerer, Dietmar
    Krismer, Martin
    Pfurner, Martin
    Biedermann, Rainer
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2015, 10