Validity, Sensitivity, Reproducibility, and Robustness of the PowerTap, Stages, and Garmin Vector Power Meters in Comparison With the SRM Device

被引:32
作者
Bouillod, Anthony [1 ]
Pinot, Julien [1 ]
Soto-Romero, Georges [2 ]
Bertucci, William [3 ]
Grappe, Frederic [1 ]
机构
[1] Sports Univ Besancon, EA4660, Hlth Sport Dept C3S, Besancon, France
[2] Natl Ctr Sci Res, Lab Anal & Architecture Syst, Toulouse, France
[3] Univ Reims, UFR STAPS, EA 4694, Grp Rech Sci Ingenieur, Reims, France
关键词
mobile power meter; power output; laboratory; field; cycling; MOBILE CYCLING POWERMETER; BILATERAL ASYMMETRY; PERFORMANCE TESTS; SPORTS-MEDICINE; TIME-TRIAL; RELIABILITY; OUTPUT; AGREEMENT; ERGOMETER; VARIABLES;
D O I
10.1123/ijspp.2016-0436
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
A large number of power meters have been produced on the market for nearly 20 y according to user requirements. Purpose: To determine the validity, sensitivity, reproducibility, and robustness of the PowerTap (PWT), Stages (STG), and Garmin Vector (VCT) power meters in comparison with the SRM device. Methods: A national-level male competitive cyclist completed 3 laboratory cycling tests: a submaximal incremental test, a submaximal 30-min continuous test, and a sprint test. Two additional tests were performed, the first on vibration exposures in the laboratory and the second in the field. Results: The VCT provided a significantly lower 5-s power output (PO) during the sprint test with a low gear ratio than the SRM did (-36.9%). The STG PO was significantly lower than the SRM PO in the heavy-exercise-intensity zone (zone 2, -5.1%) and the low part of the severeintensity zone (zone 3, -4.9%). The VCT PO was significantly lower than the SRM PO only in zone 2 (-4.5%). The STG PO was significantly lower in standing position than in the seated position (-4.4%). The reproducibility of the PWT, STG, and VCT was similar to that of the SRM system. The STG and VCT PO were significantly decreased from a vibration frequency of 48 Hz and 52 Hz, respectively. Conclusions: The PWT, STG, and VCT systems appear to be reproducible, but the validity, sensitivity, and robustness of the STG and VCT systems should be treated with some caution according to the conditions of measurement.
引用
收藏
页码:1023 / 1030
页数:8
相关论文
共 31 条
[1]   Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine [J].
Atkinson, G ;
Nevill, AM .
SPORTS MEDICINE, 1998, 26 (04) :217-238
[2]  
Balmer J, 2000, INT J SPORTS MED, V21, P195
[3]   Reliability, repeatability and reproducibility: analysis of measurement errors in continuous variables [J].
Bartlett, J. W. ;
Frost, C. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2008, 31 (04) :466-475
[4]   Validity and reliability of the PowerTap mobile cycling powermeter when compared with the SRM device [J].
Bertucci, W ;
Duc, S ;
Villerius, V ;
Pernin, JN ;
Grappe, F .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2005, 26 (10) :868-873
[5]   Validity and reliability of the axiom powertrain cycle ergometer when compared with an SRM powermeter [J].
Bertucci, W ;
Duc, S ;
Villerius, V ;
Grappe, F .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2005, 26 (01) :59-65
[6]   Validity and Reliability of the G-Cog BMX Powermeter [J].
Bertucci, W. ;
Crequy, S. ;
Chiementin, X. .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2013, 34 (06) :538-543
[7]  
Bini RR, 2015, J SPORT MED PHYS FIT, V55, P892
[8]   COMPARING METHODS OF MEASUREMENT - WHY PLOTTING DIFFERENCE AGAINST STANDARD METHOD IS MISLEADING [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1995, 346 (8982) :1085-1087
[9]  
Bouillod A, 2014, J SCI CYCLING, V3, P6
[10]  
Carpes FP, 2007, J SPORT MED PHYS FIT, V47, P51