Summary, assessment and implications of the ITER model coil test results

被引:118
作者
Mitchell, N [1 ]
机构
[1] ITER JWS, ITER Int Team, Naka, Ibaraki 3110193, Japan
关键词
D O I
10.1016/S0920-3796(03)00237-0
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Testing of the five International Thermonuclear Experimental Reactor (ITER) model coils is nearly complete and it is possible to produce an overall summary of the conductor performance assessment. The interpretation is supported by a large database of tests on components (especially strand) and by analysis of the two main phenomena that influence the strand performance in the cable (current non-uniformity and mechanical loads). Individually, interpretation of individual coils is difficult but taken together the results enable conclusions to be drawn about the expected behaviour of conductors in the ITER coils. The conductor design has successfully resolved many of the problems of stability and pulsed current behaviour associated with large multi-strand cables, and the performance is better than expected in these areas. The current sharing behaviour is below expectations, probably due to an extra unexpected strain effect in the Nb3Sn strands arising from the local magnetic loads, and the paper concentrates on this issue. Design modifications are required to recover the performance and updated design criteria to implement these are proposed. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:971 / 993
页数:23
相关论文
共 58 条
  • [1] BESSETTE D, 2002, 2002 APPL SUP C HOUS
  • [2] Application of the code THEA to the CONDOPT experiment in SULTAN
    Bottura, L
    Marinucci, C
    Bruzzone, P
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2002, 12 (01) : 1528 - 1532
  • [3] Upgrade of operating range for SULTAN test facility
    Bruzzone, P
    Anghel, A
    Fuchs, A
    Pasztor, G
    Stepanov, B
    Vogel, M
    Vecsey, G
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2002, 12 (01) : 520 - 523
  • [4] BRUZZONE P, 2002, TFCI RES AN M ST PET
  • [5] BRUZZONE P, 2002, 2002 APPL SUP C HOUS
  • [6] BRUZZONE P, 1999, TEST RESULTS HIGH FI
  • [7] BRUZZONE P, 1999, INT CRY ENG C INT CR
  • [8] BRUZZONE P, 2001, IN PRESS IEEE T APPL
  • [9] Validation of the CEA electrical network model for the ITER coils
    Ciazynski, D
    Duchateau, JL
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2001, 11 (01) : 1530 - 1533
  • [10] CIAZYNSKI D, 1999, P 16 INT C MAG TECH