Simultaneous light emitting diode-induced fluorescence and contactless conductivity detection for capillary electrophoresis

被引:37
|
作者
Tan, F [1 ]
Yang, BC [1 ]
Guan, YF [1 ]
机构
[1] Chinese Acad Sci, Dalian Inst Chem Phys, Dept Microinstrument & Analyt Chem, Dalian 116023, Peoples R China
关键词
D O I
10.2116/analsci.21.583
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A combined detection system of simultaneous contactless conductometric and fluorescent detection for capillary electrophoresis (CE) has been designed and evaluated. The two processes share a common detection cell. A blue light-emitting diode (LED) was used as the excitation source and an optical fiber was used to collect the emitting fluorescence for fluorescent detection (FD). Inorganic ions, fluorescein isothiocyanate (FITC)-labeled amino acids and small molecule peptides were separated and detected by the combined detector, and the detection limits (LODs) of sub-mu M level were achieved.
引用
收藏
页码:583 / 585
页数:3
相关论文
共 50 条
  • [1] Simultaneous Light Emitting Diode-Induced Fluorescence and Contactless Conductivity Detection for Capillary Electrophoresis
    Feng Tan
    Bingcheng Yang
    Yafeng Guan
    Analytical Sciences, 2005, 21 : 583 - 585
  • [2] Light emitting diode-induced fluorescence detection in capillary electrophoresis
    Yang, BC
    Tan, F
    Guan, YF
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2003, 31 (09) : 1066 - 1068
  • [3] Optical fiber light-emitting diode-induced fluorescence detection for capillary electrophoresis
    Zhao, SL
    Yuan, HY
    Xiao, D
    ELECTROPHORESIS, 2006, 27 (02) : 461 - 467
  • [4] Light-emitting diode-induced fluorescence detection of native proteins in capillary electrophoresis
    Sluszny, C
    He, Y
    Yeung, ES
    ELECTROPHORESIS, 2005, 26 (21) : 4197 - 4203
  • [5] An integrated light emitting diode-induced fluorescence detector for capillary electrophoresis
    Yang, Bingcheng
    Tian, Hongzhe
    Xu, Jing
    Guan, Yafeng
    TALANTA, 2006, 69 (04) : 996 - 1000
  • [6] A collinear light-emitting diode-induced fluorescence detector for capillary electrophoresis
    Yang, BC
    Tan, F
    Guan, YF
    TALANTA, 2005, 65 (05) : 1303 - 1306
  • [7] A lamp light-emitting diode-induced fluorescence detector for capillary electrophoresis
    Xu, Jing
    Xiong, Yan
    Chen, Shiheng
    Guan, Yafeng
    TALANTA, 2008, 76 (02) : 369 - 372
  • [8] Multi-wavelength light emitting diode array as an excitation source for light emitting diode-induced fluorescence detection in capillary electrophoresis
    Huo, Feng
    Yuan, Hongyan
    Breadmore, Michael C.
    Xiao, Dan
    ELECTROPHORESIS, 2010, 31 (15) : 2589 - 2595
  • [9] Separation of tyrosine enantiomer derivatives by capillary electrophoresis with light-emitting diode-induced fluorescence detection
    Bi, Weiwen
    Lei, Shaorong
    Yang, Xiupei
    Xu, Zemin
    Yuan, Hongyan
    Xiao, Dan
    Choi, Martin M. F.
    TALANTA, 2009, 78 (03) : 1167 - 1172
  • [10] Performance of an ultraviolet light-emitting diode-induced fluorescence detector in capillary electrophoresis
    Hillebrand, S
    Schoffen, JR
    Mandaji, M
    Termignoni, C
    Grieneisen, HPH
    Kist, TBL
    ELECTROPHORESIS, 2002, 23 (15) : 2445 - 2448