A compact time-resolved system for near infrared spectroscopy based on wavelength space multiplexing

被引:35
|
作者
Re, Rebecca [1 ]
Contini, Davide [1 ]
Caffini, Matteo [1 ]
Cubeddu, Rinaldo [1 ,2 ,3 ]
Spinelli, Lorenzo [2 ]
Torricelli, Alessandro [1 ,3 ]
机构
[1] Politecn Milan, Dipartimento Fis, I-20133 Milan, Italy
[2] Ist Foton & Nanotecnol, IFN CNR, I-20133 Milan, Italy
[3] Politecn Milan, Res Unit IIT, I-20133 Milan, Italy
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2010年 / 81卷 / 11期
关键词
OPTICAL-PROPERTIES; PHOTON MIGRATION; BRAIN; LIGHT; MODEL; REFLECTANCE;
D O I
10.1063/1.3495957
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We designed and developed a compact dual-wavelength and dual-channel time-resolved system for near-infrared spectroscopy studies of muscle and brain. The system employs pulsed diode lasers as sources, compact photomultipliers, and time-correlated single photon counting boards for detection. To exploit the full temporal and dynamic range of the acquisition technique, we implemented an approach based on wavelength space multiplexing: laser pulses at the two wavelengths are alternatively injected into the two channels by means of an optical 2 x 2 switch. In each detection line (i.e., in each temporal window), the distribution of photon time-of-flights at one wavelength is acquired. The proposed approach increases the signal-to-noise ratio and avoids wavelength cross-talk with respect to the typical approach based on time multiplexing. The instrument was characterized on tissue phantoms to assess its properties in terms of linearity, stability, noise, and reproducibility. Finally, it was successfully tested in preliminary in vivo measurements on muscle during standard cuff occlusion and on the brain during a motor cortex response due to hand movements. (C) 2010 American Institute of Physics. [doi:10.1063/1.3495957]
引用
收藏
页数:8
相关论文
共 50 条
  • [31] TIME-RESOLVED NEAR-INFRARED SPECTROSCOPY FOR MEASUREMENT OF CEREBRAL BLOOD-VOLUME
    KURTH, CD
    OROURKE, MM
    ARMSTEAD, WM
    ANESTHESIOLOGY, 1995, 83 (3A) : A522 - A522
  • [32] Time-resolved fluorescence polarization spectroscopy of visible and near infrared dyes in picosecond dynamics
    Pu, Yang
    Alfano, Robert R.
    FRONTIERS IN ULTRAFAST OPTICS: BIOMEDICAL, SCIENTIFIC, AND INDUSTRIAL APPLICATIONS XV, 2015, 9355
  • [33] Monitoring brain temperature by time-resolved near-infrared spectroscopy: pilot study
    Bakhsheshi, Mohammad Fazel
    Diop, Mamadou
    Lawrence, Keith St.
    Lee, Ting-Yim
    JOURNAL OF BIOMEDICAL OPTICS, 2014, 19 (05)
  • [34] Determination of oxygen saturation of cerebral blood by time-resolved near-infrared spectroscopy
    Wabnitz, H
    Steinbrink, J
    Rinneberg, H
    Obrig, H
    Villringer, A
    PTB-MITTEILUNGEN, 2001, 111 (01): : 28 - 29
  • [35] Resting hypofrontality in schizophrenia: A study using near-infrared time-resolved spectroscopy
    Hoshi, Yoko
    Shinba, Toshikazu
    Sato, Chie
    Doi, Nagafumi
    SCHIZOPHRENIA RESEARCH, 2006, 84 (2-3) : 411 - 420
  • [36] Experimental assessment of sensitivity profiles in multidistance time-resolved near infrared spectroscopy measurements
    Morawiec, Magdalena
    Sawosz, Piotr
    Maniewski, Roman
    Liebert, Adam
    DIFFUSE OPTICAL SPECTROSCOPY AND IMAGING VII, 2019, 11074
  • [37] Optical properties of drying wood studied by time-resolved near-infrared spectroscopy
    Konagaya, Keiji
    Inagaki, Tetsuya
    Kitamura, Ryunosuke
    Tsuchikawa, Satoru
    OPTICS EXPRESS, 2016, 24 (09): : 9561 - 9573
  • [38] Evaluation of Brown Adipose Tissue Using Near-Infrared Time-Resolved Spectroscopy
    Nirengi, Shinsuke
    Yoneshiro, Takeshi
    Saiki, Takeshi
    Aita, Sayuri
    Matsushita, Mami
    Sugie, Hiroki
    Saito, Masayuki
    Hamaoka, Takafumi
    OXYGEN TRANSPORT TO TISSUE XXXVII, 2016, 876 : 371 - 376
  • [39] Compact tissue oximeter based on dual-wavelength multichannel time-resolved reflectance
    Ctro. Elettron. Quantistica/S.E., Consiglio Nazionale delle Ricerche, Politecnico di Milano, Piazza Leonardo da Vinci 32, I-20133 Milan, Italy
    Appl. Opt., 16 (3670-3680):
  • [40] Compact tissue oximeter based on dual-wavelength multichannel time-resolved reflectance
    Cubeddu, R
    Pifferi, A
    Taroni, P
    Torricelli, A
    Valentini, G
    APPLIED OPTICS, 1999, 38 (16) : 3670 - 3680