Wireless Smartphone ECG Enables Large-Scale Screening in Diverse Populations

被引:155
作者
Haberman, Zachary C. [1 ]
Jahn, Ryan T. [1 ]
Bose, Rupan [1 ]
Tun, Han [1 ]
Shinbane, Jerold S. [1 ]
Doshi, Rahul N. [1 ]
Chang, Philip M. [1 ]
Saxon, Leslie A. [1 ]
机构
[1] Univ So Calif, Keck Sch Med, Los Angeles, CA 90033 USA
关键词
AliveCor; atrial fibrillation; electrocardiogram; screening; smartphone; telemetry; SUDDEN CARDIAC DEATH; ATRIAL-FIBRILLATION; ASYMPTOMATIC ADULTS; ROUTINE PRACTICE; AGED; 65; ELECTROCARDIOGRAM; RISK; RHYTHM; EFFICACY; TOOL;
D O I
10.1111/jce.12634
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Twelve-Lead ECG as a Cardiovascular Screening Tool BackgroundThe ubiquitous presence of internet-connected phones and tablets presents a new opportunity for cost-effective and efficient electrocardiogram (ECG) screening and on-demand diagnosis. Wireless, single-lead real-time ECG monitoring supported by iOS and android devices can be obtained quickly and on-demand. ECGs can be immediately downloaded and reviewed using any internet browser. ObjectiveWe compared the standard 12-lead ECG to the smartphone ECG in healthy young adults, elite athletes, and cardiology clinic patients. Accuracy for determining baseline ECG intervals and rate and rhythm was assessed. MethodsIn 381 participants, 30-second lead I ECG waveforms were obtained using an iPhone case or iPad. Standard 12-lead ECGs were acquired immediately after the smartphone tracing was obtained. De-identified ECGs were interpreted by automated algorithms and adjudicated by two board-certified electrophysiologists. ResultsBoth smartphone and standard ECGs detected atrial rate and rhythm, AV block, and QRS delay with equal accuracy. Sensitivities ranged from 72% (QRS delay) to 94% (atrial fibrillation). Specificities were all above 94% for both modalities. ConclusionSmartphone ECG accurately detects baseline intervals, atrial rate, and rhythm and enables screening in diverse populations. Efficient ECG analysis using automated discrimination and an enhanced smartphone application with notification capabilities are features that can be easily incorporated into the acquisition process.
引用
收藏
页码:520 / 526
页数:7
相关论文
共 45 条
  • [1] [Anonymous], HEART RHYTHM
  • [2] [Anonymous], PROJ WEAR UN SHIPM W
  • [3] Surface 12 lead electrocardiogram recordings using smart phone technology
    Baquero, Giselle A.
    Banchs, Javier E.
    Ahmed, Shameer
    Naccarelli, Gerald V.
    Luck, Jerry C.
    [J]. JOURNAL OF ELECTROCARDIOLOGY, 2015, 48 (01) : 1 - 7
  • [4] THE DURATION OF HOLTER MONITORING IN PATIENTS WITH SYNCOPE - IS 24 HOURS ENOUGH
    BASS, EB
    CURTISS, EI
    ARENA, VC
    HANUSA, BH
    CECCHETTI, A
    KARPF, M
    KAPOOR, WN
    [J]. ARCHIVES OF INTERNAL MEDICINE, 1990, 150 (05) : 1073 - 1078
  • [5] Birbeck G, [No title captured]
  • [6] Assessment of reproducibility - automated and digital caliper ECG measurement in the Framingham Heart Study
    Burke, Gordon M.
    Wang, Na
    Blease, Sue
    Levy, Daniel
    Magnani, Jared W.
    [J]. JOURNAL OF ELECTROCARDIOLOGY, 2014, 47 (03) : 288 - 293
  • [7] Should an electrocardiogram be included in routine preparticipation screening of young athletes?
    Chaitman, Bernard R.
    [J]. CIRCULATION, 2007, 116 (22) : 2610 - 2614
  • [8] Screening Asymptomatic Adults With Resting or Exercise Electrocardiography: A Review of the Evidence for the US Preventive Services Task Force
    Chou, Roger
    Arora, Bhaskar
    Dana, Tracy
    Fu, Rongwei
    Walker, Miranda
    Humphrey, Linda
    [J]. ANNALS OF INTERNAL MEDICINE, 2011, 155 (06) : 375 - U74
  • [9] Chung EH, 2015, J ELECTROCARDIOL, V48, P8, DOI 10.1016/j.jelectrocard.2014.10.005
  • [10] EFFICACY AND SAFETY OF QUINIDINE THERAPY FOR MAINTENANCE OF SINUS RHYTHM AFTER CARDIOVERSION - A METAANALYSIS OF RANDOMIZED CONTROL TRIALS
    COPLEN, SE
    ANTMAN, EM
    BERLIN, JA
    HEWITT, P
    CHALMERS, TC
    [J]. CIRCULATION, 1990, 82 (04) : 1106 - 1116