A concise overview of non-invasive intra-abdominal pressure measurement techniques: from bench to bedside

被引:28
作者
Tayebi, Salar [1 ]
Gutierrez, Adrian [1 ]
Mohout, Ikram [1 ]
Smets, Evelien [1 ]
Wise, Robert [2 ,3 ]
Stiens, Johan [1 ]
Malbrain, Manu L. N. G. [4 ,5 ]
机构
[1] Vrije Univ Brussel, Dept Elect & Informat, Pl Laan 2, B-1050 Brussels, Belgium
[2] Oxford Univ Hosp Trust, John Radcliffe Hosp, Adult Intens Care, Oxford, England
[3] Univ KwaZulu Natal, Sch Clin Med, Discipline Anaesthesia & Crit Care, Durban, South Africa
[4] Univ Hosp Brussel UZB, Intens Care Unit, Laarbeeklaan 101, B-1090 Jette, Belgium
[5] Vrije Univ Brussel VUB, Fac Med & Pharm, Laarbeeklaan 103, B-1090 Jette, Belgium
关键词
Non-invasive measurement; Intra-abdominal pressure; Abdominal compartment syndrome; Intensive care unit; Ultrasound; Microwave reflectometry; RESPIRATORY INDUCTIVE PLETHYSMOGRAPHY; ABDOMINAL COMPARTMENT SYNDROME; CRITICALLY-ILL PATIENTS; IN-VIVO; HYPERTENSION;
D O I
10.1007/s10877-020-00561-4
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
This review presents an overview of previously reported non-invasive intra-abdominal pressure (IAP) measurement techniques. Each section covers the basic physical principles and methodology of the various measurement techniques, the experimental results, and the advantages and disadvantages of each method. The most promising non-invasive methods for IAP measurement are microwave reflectometry and ultrasound assessment, in combination with an applied external force.
引用
收藏
页码:51 / 70
页数:20
相关论文
共 36 条
[31]   Mechanical properties of the human abdominal wall measured in vivo during insufflation for laparoscopic surgery [J].
Song, C ;
Alijani, A ;
Frank, T ;
Hanna, GB ;
Cuschieri, A .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2006, 20 (06) :987-990
[32]  
Stefanescu DM, 2011, HANDBOOK OF FORCE TRANSDUCERS: PRINCIPLES AND COMPONENTS, P1
[33]   Non-invasive measurement of intra-abdominal pressure: a preliminary study [J].
van Ramshorst, G. H. ;
Lange, J. F. ;
Goossens, R. H. M. ;
Agudelo, N. L. ;
Kleinrensink, G. J. ;
Verwaal, M. ;
Flipsen, S. F. J. ;
Hop, W. C. J. ;
Wauben, L. S. G. L. ;
Jeekel, J. .
PHYSIOLOGICAL MEASUREMENT, 2008, 29 (08) :N41-N47
[34]   Noninvasive Assessment of Intra-Abdominal Pressure by Measurement of Abdominal Wall Tension [J].
van Ramshorst, Gabrielle H. ;
Salih, Mahdi ;
Hop, Wim C. J. ;
van Waes, Oscar J. F. ;
Kleinrensink, Gert-Jan ;
Goossens, Richard H. M. ;
Lange, Johan F. .
JOURNAL OF SURGICAL RESEARCH, 2011, 171 (01) :240-244
[35]  
Wolf Gerhard K, 2005, Crit Care Med, V33, pS163, DOI 10.1097/01.CCM.0000155917.39056.97
[36]   Development of a Respiratory Inductive Plethysmography Module Supporting Multiple Sensors for Wearable Systems [J].
Zhang, Zhengbo ;
Zheng, Jiewen ;
Wu, Hao ;
Wang, Weidong ;
Wang, Buqing ;
Liu, Hongyun .
SENSORS, 2012, 12 (10) :13167-13184