Portable smartphone-based colorimetric system for simultaneous on-site microfluidic paper-based determination and mapping of phosphate, nitrite and silicate in coastal waters

被引:20
作者
Manbohi, Ahmad [1 ]
Ahmadi, Seyyed Hamid [2 ]
机构
[1] Iranian Natl Inst Oceanog & Atmospher Sci, Dept Marine Sci, Tehran 1411813389, Iran
[2] Chem & Chem Engn Res Ctr Iran, POB 14334-186, Tehran, Iran
基金
美国国家科学基金会;
关键词
Microfluidic paper-based analytical device; Smartphone application; Experimental design; Simultaneous on-site analysis; ANALYTICAL DEVICES; FABRICATION; SENSORS; COST;
D O I
10.1007/s10661-022-09860-6
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Early and on-site detection of environmental contaminations and physicochemical parameters of seawater is increasingly preferred to guarantee hazard minimization in many settings. In this paper, we describe a combination of microfluidic paper-based sensors (mu PADs) and an Android-based smartphone application (App) for simultaneous on-site quantification of phosphate (PO4-P), silicate (SiO3-Si) and nitrite (NO2-N) in coastal seawater samples. The developed App can on-site capture, process, and quantify the mu PAD colorimetric outputs. This App uses an image processing algorithm for quantifying color intensity and relating the RGB components to the analyte concentrations. The GPS-tagged data can be stored on the smartphone or sent via social networks. The significant factors affecting the detection of the analytes were optimized using Box-Behnken design. Under optimized parameters, the proposed method presented the linear ranges between 5 and 100 mu g L-1 for phosphate (R-2 = 0.9909), 5 to 100 mu g L-1 (R-2 = 0.9819) for nitrite and 10 to 600 mu g L-1 (R-2 = 0.9933) for silicate. The LODs of the method for detection of phosphate, nitrite and silicate were 1.52 mu g L-1, 0.61 mu g L-1 and 3.74 mu g L-1, respectively. The device was successfully used to simultaneous analyze and map the PO4-P, SiO3-Si and NO2-N of Bushehr coastal seawater samples (Iran). The results were confirmed by the lab-based conventional colorimetric methods using spectrophotometer.
引用
收藏
页数:16
相关论文
共 33 条
  • [1] Different morphologies of polypyrrole produced by flow-through and batch electropolymerizations: application in electrochemically controlled in-tube solid phase microextraction
    Ahmadi, Seyyed Hamid
    Manbohi, Ahmad
    [J]. RSC ADVANCES, 2014, 4 (110): : 64393 - 64401
  • [2] Chemical sensors for in situ data collection in the cryosphere
    Bagshaw, Elizabeth A.
    Beaton, Alexander
    Wadham, Jemma L.
    Mowlem, Matt
    Hawkings, Jon R.
    Tranter, Martyn
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2016, 82 : 348 - 357
  • [3] Bala R., 2003, COLOR TO GRAYSCALE C, V5293
  • [4] Determination of nitrite in saliva using microfluidic paper-based analytical devices
    Bhakta, Samir A.
    Borba, Rubiane
    Taba, Mario, Jr.
    Garcia, Carlos D.
    Carrilho, Emanuel
    [J]. ANALYTICA CHIMICA ACTA, 2014, 809 : 117 - 122
  • [5] Cardoso TMG, 2015, ANAL METHODS-UK, V7, P7311, DOI [10.1039/C5AY00466G, 10.1039/c5ay00466g]
  • [6] Caspers H, 1985, METHODS SEAWATER ANA, V70, P302, DOI [10.1002/iroh.19850700232, DOI 10.1002/IROH.19850700232]
  • [7] Recent Developments in Paper-Based Microfluidic Devices
    Cate, David M.
    Adkins, Jaclyn A.
    Mettakoonpitak, Jaruwan
    Henry, Charles S.
    [J]. ANALYTICAL CHEMISTRY, 2015, 87 (01) : 19 - 41
  • [8] Spreading dead zones and consequences for marine ecosystems
    Diaz, Robert J.
    Rosenberg, Rutger
    [J]. SCIENCE, 2008, 321 (5891) : 926 - 929
  • [9] Duffy G., 2017, THESIS DUBLIN CITY U
  • [10] On-site detection of nitrate plus nitrite in natural water samples using smartphone-based detection
    Fang, Tengyue
    Li, Hangqian
    Bo, Guangyong
    Lin, Kunde
    Yuan, Dongxing
    Ma, Jian
    [J]. MICROCHEMICAL JOURNAL, 2021, 165