Porous silicon based photoluminescence immunosensor for rapid and highly-sensitive detection of Ochratoxin A

被引:61
作者
Myndrul, Valerii [1 ]
Viter, Roman [2 ,3 ]
Savchuk, Maryna [4 ]
Shpyrka, Nelya [4 ]
Erts, Donats [2 ,3 ]
Jevdokimovs, Daniels [2 ,3 ]
Silamikelis, Viesturs [2 ,3 ]
Smyntyna, Valentyn [1 ]
Ramanavicius, Arunas [5 ]
Iatsunskyi, Igor [6 ]
机构
[1] Odessa Natl II Mechnikov Univ, Expt Phys Dept, 42 Pastera, UA-65026 Odessa, Ukraine
[2] Univ Latvia, Inst Chem Phys, 19 Raina Blvd, LV-1586 Riga, Latvia
[3] Univ Latvia, Inst Atom Phys & Spect, 19 Raina Blvd, LV-1586 Riga, Latvia
[4] Natl Univ Life & Environm Sci, 15 Geroyiv Oborony, UA-03041 Kiev, Ukraine
[5] Vilnius Univ, Fac Chem & Geosci, Inst Chem, Dept Phys Chem, Naugarduko 24, LT-03225 Vilnius, Lithuania
[6] Adam Mickiewicz Univ, NanoBioMed Ctr, 85 Umultowska Str, PL-61614 Poznan, Poland
关键词
Porous silicon; Ochratoxin A; Photoluminescence; Immobilization of antibodies; Immunosensor; RESONANCE ENERGY-TRANSFER; BIOSENSOR; APTASENSOR; APTAMER; SURFACE; WINE; NANOSTRUCTURES; SALMONELLA; SAMPLES; ELISA;
D O I
10.1016/j.bios.2017.11.048
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A rapid and low cost photoluminescence (PL) immunosensor for the determination of low concentrations of Ochratoxin A (OTA) has been developed. This immunosensor was based on porous silicon (PSi) and modified by antibodies against OTA (anti-OTA). PSi layer was fabricated by metal-assisted chemical etching (MACE) procedure. Main structural parameters (pore size, layer thickness, morphology and nanograins size) and composition of PSi were investigated by means of X-Ray diffraction (XRD), scanning electron microscopy (SEM) and Raman spectroscopy. PL-spectroscopy of PSi was performed at room temperature and showed a wide emission band centered at 680 +/- 20 nm. Protein A was covalently immobilized on the surface of PSi, which in next steps was modified by anti-OTA and BSA in this way a anti-OTA/Protein-A/PSi structure sensitive towards OTA was designed. The anti-OTA/Protein-A/PSi-based immunosensors were tested in a wide range of OTA concentrations from 0.001 upto 100 ng/ml. Interaction of OTA with anti-OTA/Protein-A/PSi surface resulted in the quenching of photoluminescence in comparison to bare PSi. The limit of detection (LOD) and the sensitivity range of anti-OTA/Protein-A/PSi immunosensors were estimated. Association constant and Gibbs free energy for the interaction of anti-OTA/Protein-A/PSi with OTA were calculated and, analyzed using the interaction isotherms. Response time of the anti-OTA/Protein-A/PSi-based immunosensor toward OTA was in the range of 500-700 s. These findings are very promising for the development of highly sensitive, and potentially portable immunosensors suitable for fast determination of OTA in food and beverages.
引用
收藏
页码:661 / 667
页数:7
相关论文
共 56 条
[41]   A review on porous silicon based electrochemical biosensors: Beyond surface area enhancement factor [J].
RoyChaudhuri, C. .
SENSORS AND ACTUATORS B-CHEMICAL, 2015, 210 :310-323
[42]   The effect of etching time of porous silicon on solar cell performance [J].
Salman, Khaldun A. ;
Omar, Khalid ;
Hassan, Z. .
SUPERLATTICES AND MICROSTRUCTURES, 2011, 50 (06) :647-658
[43]   Assay of ochratoxin A in wine and beer by high-pressure liquid chromatography photodiode array and gas chromatography mass selective detection [J].
Soleas, GJ ;
Yan, J ;
Goldberg, DM .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2001, 49 (06) :2733-2740
[44]   Enzyme biosensor systems based on porous silicon photoluminescence for detection of glucose, urea and heavy metals [J].
Syshchyk, Olga ;
Skryshevsky, Valeriy A. ;
Soldatkin, Oleksandr O. ;
Soldatkin, Alexey P. .
BIOSENSORS & BIOELECTRONICS, 2015, 66 :89-94
[45]   Optical biosensors based on ZnO nanostructures: advantages and perspectives. A review [J].
Tereshchenko, Alla ;
Bechelany, Mikhael ;
Viter, Roman ;
Khranovskyy, Volodymyr ;
Smyntyna, Valentyn ;
Starodub, Nikolay ;
Yakimova, Rositza .
SENSORS AND ACTUATORS B-CHEMICAL, 2016, 229 :664-677
[46]   Towards a subcutaneous optical biosensor based on thermally hydrocarbonised porous silicon [J].
Tong, Wing Yin ;
Sweetman, Martin J. ;
Marzouk, Ezzat R. ;
Fraser, Cara ;
Kuchel, Tim ;
Voelcker, Nicolas H. .
BIOMATERIALS, 2016, 74 :217-230
[47]   Label-Free Optical Biosensors Based on Aptamer-Functionalized Porous Silicon Scaffolds [J].
Urmann, Katharina ;
Walter, Johanna-Gabriela ;
Scheper, Thomas ;
Segal, Ester .
ANALYTICAL CHEMISTRY, 2015, 87 (03) :1999-2006
[48]   Bioanalytical system for detection of cancer cells with photoluminescent ZnO nanorods [J].
Viter, R. ;
Jekabsons, K. ;
Kalnina, Z. ;
Poletaev, N. ;
Hsu, S. H. ;
Riekstina, U. .
NANOTECHNOLOGY, 2016, 27 (46)
[49]   Novel Immune TiO2 Photoluminescence Biosensors for Leucosis Detection [J].
Viter, R. ;
Smyntyna, V. ;
Starodub, N. ;
Tereshchenko, A. ;
Kusevitch, A. ;
Doychoa, I. ;
Geveluk, S. ;
Slishik, N. ;
Buk, J. ;
Duchoslav, J. ;
Lubchuk, J. ;
Konup, I. ;
Ubelis, A. ;
Spigulis, J. .
26TH EUROPEAN CONFERENCE ON SOLID-STATE TRANSDUCERS, EUROSENSOR 2012, 2012, 47 :338-341
[50]   Analytical, thermodynamical and kinetic characteristics of photoluminescence immunosensor for the determination of Ochratoxin A [J].
Viter, Roman ;
Savchuk, Maryna ;
Iatsunskyi, Igor ;
Pietralik, Zuzanna ;
Starodub, Nikolay ;
Shpyrka, Nelya ;
Ramanaviciene, Almira ;
Ramanavicius, Arunas .
BIOSENSORS & BIOELECTRONICS, 2018, 99 :237-243