Highly selective direct determination of chlorate ions by using a newly developed potentiometric electrode based on modified smectite

被引:24
作者
Topcu, Cihan [1 ]
机构
[1] Erzincan Univ, Fac Arts & Sci, Dept Chem, Erzincan, Turkey
关键词
Chlorate selective electrode; Potentiometric chlorate determination; Modified smectite; Water analysis; FLOW-INJECTION ANALYSIS; CARBON-PASTE ELECTRODE; MEMBRANE-ELECTRODE; SPECTROPHOTOMETRIC DETERMINATION; ACTIVE COMPONENT; DRINKING-WATER; MODIFIED CLINOPTILOLITE; IODOMETRIC METHOD; LEVEL CHLORATE; SURFACTANT;
D O I
10.1016/j.talanta.2016.09.018
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel polyvinyl chloride membrane chlorate (ClO3-) selective electrode based on modified smectite was developed for the direct determination of chlorate ions and the potentiometric performance characteristics of its were examined. The best selectivity and sensitivity for chlorate "ions were obtained for the electrode membrane containing ionophore/polyvinylchloride/o-nitrophenyloctylether in composition of 12/28/60 (w/w%). The proposed electrode showed a Nernstian response toward chlorate ions at pH=7 in the concentration range of 1 x 10(-7)-1 x 10(-1) M and the limit of detection was calculated as 9 x 10(-8) M from the constructed response plot. The linear slope of the electrode was -61 +/- 1 mV decade(-1) for chlorate activity in the mentioned linear working range. The selectivity coefficients were calculated according to both the matched potential method and the separate solution method. The calculated selectivity coefficients showed that the electrode performed excellent selectivity for chlorate ions. The potentiometric response of electrode toward chlorate ions was found to be highly reproducible. The electrode potential was stable between pH=4-10 and it had a dynamic response time of <5 s. The potentiometric behavior of the electrode in partial non-aqueous medium was also investigated and the obtained results (up to 5% (v/v) alcohol) were satisfactory. The proposed electrode was used during 15 weeks without any significant change in its potential response. Additionally, the electrode was very useful in water analysis studies such as dam water, river water, tap water, and swimming pool water where the direct determination of chlorate ions was required. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:623 / 631
页数:9
相关论文
共 50 条
[31]   Highly Sensitive and Selective Voltammetric Sensor Fullerene Modified Glassy Carbon Electrode for Determination of Cefitizoxime in Solubilized System [J].
Jain, Rajeev ;
Rather, Jahangir Ahmad ;
Dwivedi, Ashish ;
Vikas .
ELECTROANALYSIS, 2010, 22 (21) :2600-2606
[32]   Potentiometric flow-injection determination of cysteine in the presence of cystine using a tubular electrode with Ag(I)-based membrane as detector [J].
Komljenovic, J ;
Radic, N .
ANALUSIS, 1996, 24 (03) :63-65
[33]   Highly sensitive determination of nitrite using FMWCNTs-conducting polymer composite modified electrode [J].
Rajalakshmi, K. ;
John, S. Abraham .
SENSORS AND ACTUATORS B-CHEMICAL, 2015, 215 :119-124
[34]   Determination of Atomoxetine Hydrochloride in Biological Fluids Using Potentiometric Carbon Paste Electrode Modified by TiO2 Nanoparticles [J].
Abu Shawish, Hazem M. ;
Tamous, Hassan ;
Saadeh, Salman M. ;
Tbaza, Ahmad .
ACTA CHIMICA SLOVENICA, 2018, 65 (04) :811-822
[35]   Selective Determination of Total Capsaicinoids in Plant Material Using Poly(Gallic Acid)-modified Electrode [J].
Ziyatdinova, Guzel ;
Kozlova, Ekaterina ;
Budnikov, Herman ;
Davletshin, Rustam .
ELECTROANALYSIS, 2019, 31 (02) :222-230
[36]   Highly selective and sensitive voltammetric sensor based on modified multiwall carbon nanotube paste electrode for simultaneous determination of ascorbic acid, acetaminophen and tryptophan [J].
Keyvanfard, Mohsen ;
Shakeri, Razieh ;
Karimi-Maleh, Hassan ;
Alizad, Khadijeh .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2013, 33 (02) :811-816
[37]   Preparation, Characterization of Novel Cadmium-Based Metal-Organic Framework for Using as a Highly Selective and Sensitive Modified Carbon Paste Electrode in Determination of Cu(II) Ion [J].
Deghadi, Reem G. ;
Eliwa, Ayman S. ;
Ali, Aya E. ;
Hosny, Wafaa M. ;
Mohamed, Gehad G. .
COMMENTS ON INORGANIC CHEMISTRY, 2021, 41 (04) :189-212
[38]   Zinc ion-imprinted polymer based on silica particles modified carbon paste electrodes for highly selective electrochemical determination of zinc ions [J].
Khairnar, Nilesh A. ;
Jirimali, Harishchandra D. ;
Patil, Kailas P. ;
Gite, Vikas V. .
POLYMER-PLASTICS TECHNOLOGY AND MATERIALS, 2020, 59 (15) :1698-1714
[39]   A mercury free electrode for anodic stripping voltammetric determination of Pb (II) ions using poly zincon film modified electrode [J].
Vasanthi, S. ;
Devendiran, M. ;
Narayanan, S. Sriman .
APPLIED SURFACE SCIENCE, 2017, 422 :138-146
[40]   A highly sensitive method for determination of paracetamol by adsorptive stripping voltammetry using a carbon paste electrode modified with nanogold and glutamic acid [J].
Zhang, Ying ;
Luo, Liqiang ;
Ding, Yaping ;
Liu, Xiao ;
Qian, Zheyuan .
MICROCHIMICA ACTA, 2010, 171 (1-2) :133-138