Highly selective direct determination of chlorate ions by using a newly developed potentiometric electrode based on modified smectite

被引:23
作者
Topcu, Cihan [1 ]
机构
[1] Erzincan Univ, Fac Arts & Sci, Dept Chem, Erzincan, Turkey
关键词
Chlorate selective electrode; Potentiometric chlorate determination; Modified smectite; Water analysis; FLOW-INJECTION ANALYSIS; CARBON-PASTE ELECTRODE; MEMBRANE-ELECTRODE; SPECTROPHOTOMETRIC DETERMINATION; ACTIVE COMPONENT; DRINKING-WATER; MODIFIED CLINOPTILOLITE; IODOMETRIC METHOD; LEVEL CHLORATE; SURFACTANT;
D O I
10.1016/j.talanta.2016.09.018
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel polyvinyl chloride membrane chlorate (ClO3-) selective electrode based on modified smectite was developed for the direct determination of chlorate ions and the potentiometric performance characteristics of its were examined. The best selectivity and sensitivity for chlorate "ions were obtained for the electrode membrane containing ionophore/polyvinylchloride/o-nitrophenyloctylether in composition of 12/28/60 (w/w%). The proposed electrode showed a Nernstian response toward chlorate ions at pH=7 in the concentration range of 1 x 10(-7)-1 x 10(-1) M and the limit of detection was calculated as 9 x 10(-8) M from the constructed response plot. The linear slope of the electrode was -61 +/- 1 mV decade(-1) for chlorate activity in the mentioned linear working range. The selectivity coefficients were calculated according to both the matched potential method and the separate solution method. The calculated selectivity coefficients showed that the electrode performed excellent selectivity for chlorate ions. The potentiometric response of electrode toward chlorate ions was found to be highly reproducible. The electrode potential was stable between pH=4-10 and it had a dynamic response time of <5 s. The potentiometric behavior of the electrode in partial non-aqueous medium was also investigated and the obtained results (up to 5% (v/v) alcohol) were satisfactory. The proposed electrode was used during 15 weeks without any significant change in its potential response. Additionally, the electrode was very useful in water analysis studies such as dam water, river water, tap water, and swimming pool water where the direct determination of chlorate ions was required. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:623 / 631
页数:9
相关论文
共 50 条
  • [21] A simple and selective flow-injection potentiometric method for determination of iodide based on a coated glassy carbon electrode sensor
    Beheshti, Saeed S.
    Amini, Mohammad K.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2007, 2 (10): : 778 - 787
  • [22] USING CHROMIUM MODIFIED CARBON PASTE ELECTRODE FOR HEAVY METAL IONS DETERMINATION
    Koudelkova, Zuzana
    Zawrotna, Natalia
    Jelinkova, Pavlina
    Richtera, Lukas
    Adam, Vojtech
    PROCEEDINGS OF INTERNATIONAL PHD STUDENTS CONFERENCE, (MENDELNET 2016), 2016, : 994 - 998
  • [23] Potentiometric determination of Cd(II) ions using PVC-based polyaniline Sn(IV) silicate composite cation-exchanger ion-selective membrane electrode
    Naushad, Mu
    Inamuddin
    Rangreez, Tauseef Ahmad
    DESALINATION AND WATER TREATMENT, 2015, 55 (02) : 463 - 470
  • [24] Individual and Simultaneous Determination of Heavy Metal Ions Using Carbon Paste Electrode Modified with Titania Nanoparticles
    Tuzun, Elif
    Atun, Gulten
    ELECTROCATALYSIS, 2023, 14 (04) : 636 - 647
  • [25] Potentiometric Determination of Dopamine Using a Solid-Contact Polymeric Membrane Ion-Selective Electrode
    Yin, Tanji
    Qin, Wei
    SENSOR LETTERS, 2013, 11 (03) : 607 - 612
  • [26] Highly Sensitive Determination of Theophylline Based on Graphene Quantum Dots Modified Electrode
    Ganjali, Mohammad Reza
    Dourandish, Zahra
    Beitollahi, Hadi
    Tajik, Somayeh
    Hajiaghababaei, Leila
    Larijani, Bagher
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (03): : 2448 - 2461
  • [27] Selective Electrochemical Determination of Desipramine Using a Lipid Modified Carbon Paste Electrode
    Khodari, Mahmoud
    XXXV MODERNI ELEKTROCHEMICKE METODY, 2015, : 100 - 103
  • [28] Potentiometric determination of nitrazepam in pharmaceutical dosage form and spiked plasma using a novel modified carbon paste electrode
    Azab, Marwa M.
    Rizk, Mohamed
    Mohamed, Omaima M.
    Farag, Amir Shaaban
    ELECTROANALYSIS, 2024, 36 (11)
  • [29] Potentiometric Determination of Mepivacaine Hydrochloride Local Anesthetic Drug in Pharmaceutical and Biological Fluids Using Ion Selective Electrode
    Ali, Tamer Awad
    Mohamed, Gehad G.
    Abd El-Hamid, N. S.
    EGYPTIAN JOURNAL OF CHEMISTRY, 2021, 64 (07): : 3323 - 3334
  • [30] Modified carbon paste electrode with ionic liquid and SiO2 nanoparticles for potentiometric determination of Copper(II) ions in real samples
    SoheilaSaghiri
    Ebrahimi, Mahmoud
    Beyramabadi, Safar Ali
    INTERNATIONAL JOURNAL OF MEDICAL RESEARCH & HEALTH SCIENCES, 2016, 5 (08): : 326 - 331