In vitro stabilizing effect of a transforaminal compared with two posterior lumbar interbody fusion cages

被引:79
作者
Kettler, A [1 ]
Schmoelz, W [1 ]
Kast, E [1 ]
Gottwald, M [1 ]
Claes, L [1 ]
Wilke, HJ [1 ]
机构
[1] Univ Ulm, Inst Orthopaed Res & Biomech, Dept Unfallchirurg Forsch & Biomech, D-89081 Ulm, Germany
关键词
lumbar spine; interbody fusion; cage; primary stability; biomechanics;
D O I
10.1097/01.brs.0000186466.01542.8c
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. An in vitro biomechanical flexibility test on different lumbar interbody fusion cages using mono-segmental lumbar spine specimens. Objective. To investigate the stabilizing effect of a transforaminal lumbar interbody fusion (TLIF) cage compared with two established posterior lumbar interbody fusion (PLIF) cages. Summary of Background Data. TLIF using interbody fusion cages is gaining more and more popularity in the treatment of degenerative disc disease. However, only little is known on its biomechanical behavior. Methods. Eighteen intact human lumbar spine segments were tested for flexibility in a specially designed spine tester. Pure moments were applied in the three main planes, and range of motion and neutral zone were determined. Then, TLIF using the sickle-shaped MOON cage (AMT AG), PLIF using the cubic Stryker cages (Stryker Orthopaedics), or PLIF using the threaded BAK cages (Zimmer Spinetech) was carried out and the specimens tested again. Results. The stability after implantation of the MOON TLIF cage did not significantly differ from that after implantation of the cubic Stryker PLIF cages (P > 0.05). In contrast, the threaded BAK PLIF cages had a significantly higher primary stability than both the MOON TLIF and the Stryker PLIF cages in lateral bending, flexion, and extension ( P < 0.05) but not in axial rotation (P > 0.05). Conclusions. In terms of its stabilizing effect, TLIF using the MOON cage can be recommended as an alternative to PLIF using the cubic Stryker cages. Compared with the threaded BAK PLIF cages, however, the MOON TLIF cage provides a lower primary stability in lateral bending, flexion, and extension.
引用
收藏
页码:E665 / E670
页数:6
相关论文
共 23 条
[1]  
BAGBY GW, 1988, ORTHOPEDICS, V11, P931
[2]   Posterior augmentation of an anterior lumbar interbody fusion -: Minimally invasive fixation versus pedicle screws in vitro [J].
Beaubien, BP ;
Mehbod, AA ;
Kallemeier, PM ;
Lew, WD ;
Buttermann, GR ;
Transfeldt, EE ;
Wood, KB .
SPINE, 2004, 29 (19) :E406-E412
[3]  
Brau Salvador A, 2004, Spine J, V4, P409, DOI 10.1016/j.spinee.2003.12.003
[4]   Pullout test with three lumbar interbody fusion cages [J].
Dietl, RHJ ;
Krammer, M ;
Kettler, A ;
Wilke, HJ ;
Claes, L ;
Lumenta, CB .
SPINE, 2002, 27 (10) :1029-1035
[5]   Transforaminal lumbar interbody fusion: a safe technique with satisfactory three to five year results [J].
Hackenberg, L ;
Halm, H ;
Bullmann, V ;
Vieth, V ;
Schneider, M ;
Liljenqvist, U .
EUROPEAN SPINE JOURNAL, 2005, 14 (06) :551-558
[6]   Transforaminal lumbar interbody fusion - The effect of various instrumentation techniques on the flexibility of the lumbar spine [J].
Harris, BM ;
Hilibrand, AS ;
Savas, PE ;
Pellegrino, A ;
Vaccaro, AR ;
Siegler, S ;
Albert, TJ .
SPINE, 2004, 29 (04) :E65-E70
[7]  
Heth J A, 2001, Spine (Phila Pa 1976), V26, pE261, DOI 10.1097/00007632-200106150-00012
[8]   Spinal stability with anterior or posterior Ray threaded fusion cages [J].
Hitchon, PW ;
Goel, V ;
Rogge, T ;
Dooris, A ;
Drake, J ;
Torner, J .
JOURNAL OF NEUROSURGERY, 2000, 93 (01) :102-108
[9]  
Humphreys SC, 2001, SPINE, V26, P567
[10]  
Jost B, 1998, Eur Spine J, V7, P132