Measurement Uncertainty in Battery Electrochemical Impedance Spectroscopy

被引:17
作者
Moradpour, Amin [1 ]
Kasper, Manuel [1 ]
Hoffmann, Johannes [2 ]
Kienberger, Ferry [1 ]
机构
[1] Keysight Technol GmbH, Keysight Labs Linz, A-4020 Linz, Austria
[2] Fed Inst Metrol METAS Switzerland, RF & Microwave Lab, CH-3003 Bern, Switzerland
基金
欧盟地平线“2020”;
关键词
Electrochemical impedance spectroscopy (EIS); impedance calibration; impedance uncertainty characterization; lithium-ion batteries (LiBs); S-PARAMETER MEASUREMENT; LITHIUM-ION BATTERIES; CHARGE; STATE; CALIBRATION; RELAXATION; SELECTION; HEALTH;
D O I
10.1109/TIM.2022.3198466
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Electrochemical impedance spectroscopy (EIS) is a widely used method for battery tests in manufacturing and automotive field applications. As such, accurate measurement of the impedance over a broad frequency spectrum is of high relevance, also requiring specific calibration methods and evaluation of error bounds. Here, we report for the first time a comprehensive uncertainty analysis of calibrated EIS for batteries. We aim to identify two uncertainty sources, the fixture repeatability and measurement noise, and evaluate their effect on the measured impedances. To this end, an error model assigned to each of them and the real and imaginary parts of the model parameters are characterized in the frequency range of 100 mHz-5 kHz by performing specific impedance measurements on a shunt resistor and a short standard. We demonstrate how different uncertainties are combined with the measured impedances, incorporating also the impedance calibration procedure. The errors are propagated through the calibration and correction functions by applying the linear error propagation method provided by the UncLib package from METAS. The error bounds are derived from uncertainty propagation in the shunt standard and the prismatic battery cell EIS and verified by conducting a series of measurements. Thereby, the uncertainty is shown as ellipsoids in every frequency point of the Nyquist plot. For instance, at 1 Hz, the 34-Ah prismatic cell shows a calibrated real-part impedance and two standard deviation error bounds of 1.07 m Omega +/- 26 mu Omega.
引用
收藏
页数:9
相关论文
共 27 条
[1]   Characterization of high-power lithium-ion batteries by electrochemical impedance spectroscopy. II: Modelling [J].
Andre, D. ;
Meiler, M. ;
Steiner, K. ;
Walz, H. ;
Soczka-Guth, T. ;
Sauer, D. U. .
JOURNAL OF POWER SOURCES, 2011, 196 (12) :5349-5356
[2]   Characterization of high-power lithium-ion batteries by electrochemical impedance spectroscopy. I. Experimental investigation [J].
Andre, D. ;
Meiler, M. ;
Steiner, K. ;
Wimmer, Ch ;
Soczka-Guth, T. ;
Sauer, D. U. .
JOURNAL OF POWER SOURCES, 2011, 196 (12) :5334-5341
[3]   Battery aging assessment and parametric study of lithium-ion batteries by means of a fractional differential model [J].
De Sutter, Lysander ;
Firouz, Yousef ;
De Hoog, Joris ;
Omar, Noshin ;
Van Mierlo, Joeri .
ELECTROCHIMICA ACTA, 2019, 305 :24-36
[4]   Performance analysis and SOH (state of health) evaluation of lithium polymer batteries through electrochemical impedance spectroscopy [J].
Galeotti, Matteo ;
Cina, Lucio ;
Giammanco, Corrado ;
Cordiner, Stefano ;
Di Carlo, Aldo .
ENERGY, 2015, 89 :678-686
[5]  
Ghilani C.D., 2017, Adjustment computations: Spatial data analysis
[6]   Online Estimation of the Electrochemical Impedance Spectrum and Remaining Useful Life of Lithium-Ion Batteries [J].
Guha, Arijit ;
Patra, Amit .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2018, 67 (08) :1836-1849
[7]   Exploring Differences between Charge and Discharge of LiMn2O4/Li Half-cell with Dynamic Electrochemical Impedance Spectroscopy [J].
Huang, Jun ;
Zhang, Jianbo ;
Li, Zhe ;
Song, Shaoling ;
Wu, Ningning .
ELECTROCHIMICA ACTA, 2014, 131 :228-235
[9]   Electrochemical impedance spectroscopy error analysis and round robin on dummy cells and lithium-ion-batteries [J].
Kasper, Manuel ;
Leike, Arnd ;
Thielmann, Johannes ;
Winkler, Christian ;
R-Smith, Nawfal Al-Zubaidi ;
Kienberger, Ferry .
JOURNAL OF POWER SOURCES, 2022, 536
[10]   Analytical Uncertainty Evaluation of Material Parameter Measurements at THz Frequencies [J].
Kazemipour, Alireza ;
Wollensack, Michael ;
Hoffmann, Johannes ;
Hudlicka, Martin ;
Yee, See-Khee ;
Rufenacht, Jurg ;
Stalder, Daniel ;
Gaumann, Gregory ;
Zeier, Markus .
JOURNAL OF INFRARED MILLIMETER AND TERAHERTZ WAVES, 2020, 41 (10) :1199-1217