Quantification of metal-induced susceptibility artifacts associated with ultrahigh-field magnetic resonance imaging of spinal implants

被引:14
作者
Chiba, Yusuke [1 ]
Murakami, Hideki [1 ]
Sasaki, Makoto [2 ]
Endo, Hirooki [1 ]
Yamabe, Daisuke [1 ]
Kinno, Daichi [1 ]
Doita, Minoru [1 ]
机构
[1] Iwate Med Univ, Sch Med, Dept Orthoped, 19-1 Uchimaru, Morioka, Iwate 0208505, Japan
[2] Iwate Med Univ, Inst Biomed Sci, Div Ultrahigh Field MRI, Morioka, Iwate, Japan
关键词
7T; artifact; metallic spinal implants; zero echo time; COBALT-CHROMIUM; MRI; CLARITY; QUIET;
D O I
10.1002/jsp2.1064
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Reports on spinal-implant metallic artifacts in 7-T magnetic resonance imaging (MRI) are lacking. Thus, we investigated the magnitude of metal artifacts derived from spinal implants in 7-T MRI and analyzed the differences obtained with spinal rods manufactured from pure titanium, titanium alloy, and cobalt-chrome (5.5-mm and 6.0-mm diameters and 50-mm length). Following the American Society for Testing and Materials guidelines, we measured the artifact size and artifact volume ratio of each rod during image acquisition using 7-T MRI scanners with three-dimensional (3D) T1-weighted and 3D T2* spoiled gradient echo (GRE), 3D T2-weighted fast spin echo, zero echo time (ZTE), and diffusion-weighted imaging sequences. Pure titanium and titanium alloy rods yielded significantly smaller artifacts than did cobalt-chrome rods, with no significant difference between pure titanium and titanium alloy rods. The artifact sizes of the 5.5-mm and 6.0-mm diameter rods were similar. The artifact magnitude increased in the following sequence order: ZTE, 3D T2 fast spin echo, 3D T1 spoiled GRE, 3D T2* spoiled GRE, and diffusion-weighted imaging. Artifacts obtained using the spin echo method were smaller than those obtained with the GRE method. Because the echo time in ZTE is extremely short, the occurrence of artifacts because of image distortion and signal loss caused by differences in magnetic susceptibility is minimal, resulting in the smallest artifacts. ZTE can be a clinically useful method for the postoperative evaluation of patients after instrumentation surgery, even with 7-T MRI.
引用
收藏
页数:7
相关论文
共 22 条
[1]   Postoperative magnetic resonance imaging artifact with cobalt-chromium versus titanium spinal instrumentation [J].
Ahmad, Faiz U. ;
Sidani, Charif ;
Fourzali, Roberto ;
Wang, Michael Y. .
JOURNAL OF NEUROSURGERY-SPINE, 2013, 19 (05) :629-636
[2]   Acoustic noise reduction in MRI using Silent Scan: an initial experience [J].
Alibek, Sedat ;
Vogel, Mika ;
Sun, Wei ;
Winkler, David ;
Baker, Christopher A. ;
Burke, Michael ;
Gloger, Hubertus .
DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2014, 20 (04) :360-363
[3]  
[Anonymous], 2013, F211907 ASTM INT
[4]  
[Anonymous], 2006, F205206 ASTM
[5]   In vitro stent assessment by MRI: visibility of lumen and artifacts for 27 modern stents [J].
Heinrich, Andreas ;
Guettler, Felix V. ;
Schlesies, Florian ;
Aschenbach, Rene ;
Eckardt, Niklas ;
Teichgraeber, Ulf K-M. .
BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2017, 62 (06) :565-573
[6]   Clinical Evaluation of Silent T1-Weighted MRI and Silent MR Angiography of the Brain [J].
Holdsworth, Samantha J. ;
Macpherson, Sarah J. ;
Yeom, Kristen W. ;
Wintermark, Max ;
Zaharchuk, Greg .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 210 (02) :404-411
[7]   Fast and quiet MRI using a swept radiofrequency [J].
Idiyatullin, Djaudat ;
Corum, Curt ;
Park, Jang-Yeon ;
Garwood, Michael .
JOURNAL OF MAGNETIC RESONANCE, 2006, 181 (02) :342-349
[8]   An Eight-Channel Phased Array RF Coil for Spine MR Imaging at 7 T [J].
Kraff, Oliver ;
Bitz, Andreas K. ;
Kruszona, Stefan ;
Orzada, Stephan ;
Schaefer, Lena C. ;
Theysohn, Jens M. ;
Maderwald, Stefan ;
Ladd, Mark E. ;
Quick, Harald H. .
INVESTIGATIVE RADIOLOGY, 2009, 44 (11) :734-740
[9]   Ultrashort echo time and zero echo time MRI at 7T [J].
Larson, Peder E. Z. ;
Han, Misung ;
Krug, Roland ;
Jakary, Angela ;
Nelson, Sarah J. ;
Vigneron, Daniel B. ;
Henry, Roland G. ;
McKinnon, Graeme ;
Kelley, Douglas A. C. .
MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2016, 29 (03) :359-370
[10]   ULTRA-FAST IMAGING USING LOW FLIP ANGLES AND FIDS [J].
MADIO, DP ;
LOWE, IJ .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (04) :525-529