Accuracy of MDCT and CBCT in three-dimensional evaluation of the oropharynx morphology

被引:30
作者
Chen, Hui [1 ,2 ,3 ]
van Eijnatten, Maureen [3 ,4 ,5 ]
Aarab, Ghizlane [2 ,3 ]
Forouzanfar, Tim [3 ,4 ,5 ]
de Lange, Jan [3 ,6 ,7 ]
van der Stelt, Paul [1 ]
Lobbezoo, Frank [2 ,3 ]
Wolff, Jan [3 ,4 ,5 ]
机构
[1] Univ Amsterdam, Acad Ctr Dent Amsterdam ACTA, Dept Oral Radiol, Amsterdam, Netherlands
[2] Univ Amsterdam, Oral Kinesiol, Acad Ctr Dent Amsterdam ACTA, Amsterdam, Netherlands
[3] Vrije Univ Amsterdam, Amsterdam, Netherlands
[4] Univ Amsterdam, Innovat Lab 3D, Dept Oral & Maxillofacial Surg Oral Pathol, ACTA, Amsterdam, Netherlands
[5] Univ Amsterdam, VU Univ Med Ctr, Amsterdam, Netherlands
[6] Univ Amsterdam, ACTA, Dept Oral & Maxillofacial Surg, Amsterdam, Netherlands
[7] Univ Amsterdam, Acad Med Ctr, Amsterdam, Netherlands
关键词
BEAM COMPUTED-TOMOGRAPHY; OBSTRUCTIVE SLEEP-APNEA; UPPER-AIRWAY; IMAGE QUALITY; CT; RELIABILITY; ADVANCEMENT; DOSIMETRY; DEVICES;
D O I
10.1093/ejo/cjx030
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To assess the accuracy of five different computed tomography (CT) scanners for the evaluation of the oropharynx morphology. Methods: An existing cone-beam computed tomography (CBCT) data set was used to fabricate an anthropomorphic phantom of the upper airway volume that extended from the uvula to the epiglottis (oropharynx) with known dimensions (gold standard). This phantom was scanned using two multi-detector row computed tomography (MDCT) scanners (GE Discovery CT750 HD, Siemens Somatom Sensation) and three CBCT scanners (NewTom 5G, 3D Accuitomo 170, Vatech PaX Zenith 3D). All CT images were segmented by two observers and converted into standard tessellation language (STL) models. The volume and the cross-sectional area of the oropharynx were measured on the acquired STL models. Finally, all STL models were registered and compared with the gold standard. Results: The intra-and inter-observer reliability of the oropharynx segmentation was fair to excellent. The most accurate volume measurements were acquired using the Siemens MDCT (98.4%; 14.3 cm(3)) and Vatech CBCT (98.9%; 14.4 cm(3)) scanners. The GE MDCT, NewTom 5G CBCT, and Accuitomo CBCT scanners resulted in smaller volumes, viz., 92.1% (13.4 cm(3)), 91.5% (13.3 cm(3)), and 94.6% (13.8 cm(3)), respectively. The most accurate cross-sectional area measurements were acquired using the Siemens MDCT (94.6%; 282.4 mm(2)), Accuitomo CBCT (95.1%; 283.8 mm(2)), and Vatech CBCT (95.3%; 284.5 mm(2)) scanners. The GE MDCT and NewTom 5G CBCT scanners resulted in smaller areas, viz., 89.3% (266.5 mm(2)) and 89.8% (268.0 mm(2)), respectively. Limitations: Images of the phantom were acquired using the vendor-supplied default airway scanning protocol for each scanner. Conclusion: Significant differences were observed in the volume and cross-sectional area measurements of the oropharynx acquired using different MDCT and CBCT scanners. The Siemens MDCT and the Vatech CBCT scanners were more accurate than the GE MDCT, NewTom 5G, and Accuitomo CBCT scanners. In clinical settings, CBCT scanners offer an alternative to MDCT scanners in the assessment of the oropharynx morphology.
引用
收藏
页码:58 / 64
页数:7
相关论文
共 35 条
[1]   Oral Appliance Therapy versus Nasal Continuous Positive Airway Pressure in Obstructive Sleep Apnea: A Randomized, Placebo-Controlled Trial [J].
Aarab, Ghizlane ;
Lobbezoo, Frank ;
Hamburger, Hans L. ;
Naeije, Machiel .
RESPIRATION, 2011, 81 (05) :411-419
[2]   Three-Dimensional Computed Tomographic Analysis of Airway Anatomy in Patients With Obstructive Sleep Apnea [J].
Abramson, Zachary ;
Susarla, Srinivas ;
August, Meredith ;
Troulis, Maria ;
Kaban, Leonard .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2010, 68 (02) :354-362
[3]   Three-dimensional segmentation of the upper airway using cone beam CT: a systematic review [J].
Alsufyani, N. A. ;
Flores-Mir, C. ;
Major, P. W. .
DENTOMAXILLOFACIAL RADIOLOGY, 2012, 41 (04) :276-284
[4]   CT segmentation of dental shapes by anatomy-driven reformation imaging and B-spline modelling [J].
Barone, S. ;
Paoli, A. ;
Razionale, A. V. .
INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2016, 32 (06) :1-17
[5]   Reliability and accuracy of cone-beam computed tomography dental measurements [J].
Baumgaertel, Sebastian ;
Palomo, J. Martin ;
Palomo, Leena ;
Hans, Mark G. .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 136 (01) :19-25
[6]   Cone-beam CT analysis of patients with obstructive sleep apnea compared to normal controls [J].
Buchanan, Allison ;
Cohen, Ruben ;
Looney, Stephen ;
Kalathingal, Sajitha ;
De Rossi, Scott .
IMAGING SCIENCE IN DENTISTRY, 2016, 46 (01) :9-16
[7]   Three-Dimensional Evaluation of Upper Airway in Patients With Obstructive Sleep Apnea Syndrome During Oral Appliance Therapy [J].
Cossellu, Gianguido ;
Biagi, Roberto ;
Sarcina, Michele ;
Mortellaro, Carmen ;
Farronato, Giampietro .
JOURNAL OF CRANIOFACIAL SURGERY, 2015, 26 (03) :745-748
[8]  
Emadi Naghmeh, 2014, Iran Endod J, V9, P283
[9]  
Fleiss J.L., 1986, The Design and Analysis of Clinical Experiments, P1
[10]   Sleep-related breathing disorders in adults: Recommendations for syndrome definition and measurement techniques in clinical research [J].
Flemons, WW ;
Buysse, D ;
Redline, S ;
Pack, A ;
Strohl, K ;
Wheatley, J ;
Young, T ;
Douglas, N ;
Levy, P ;
McNicholas, W ;
Fleetham, J ;
White, D ;
Schmidt-Nowarra, W ;
Carley, D ;
Romaniuk, J .
SLEEP, 1999, 22 (05) :667-689