Grid-connected PV systems installed on institutional buildings: Technology comparison, energy analysis and economic performance

被引:97
|
作者
Allouhi, A. [1 ]
Saadani, R. [2 ]
Kousksou, T. [3 ]
Saidur, R. [4 ]
Jamil, A. [1 ]
Rahmoune, M. [2 ]
机构
[1] Univ Sidi Mohamed Ben Abdellah, Ecole Super Technol Fes, Route Imouzzer BP 2427, Fes, Morocco
[2] Univ Monday Ismail, Ecole Super Technol Meknes, Km 5,Rue Agouray,BP 3103, Meknes 50040, Toulal, Morocco
[3] Univ Pau & Pays Adour, Lab Sci Ingenieur Appl Mecan & Genie Elect SIAME, IFR A Jules Ferry, F-64000 Pau, France
[4] King Fahd Univ Petr & Minerals, Res Inst, Ctr Res Excellence Renewable Energy CoRE RE, Dhahran 31261, Saudi Arabia
关键词
Grid-connected; Photovoltaic; Institutional building; Performance ratio; Efficiency; SOLAR PHOTOVOLTAIC SYSTEMS; LIFE-CYCLE ASSESSMENT; MOROCCO; CONSUMPTION; POLICIES; ROOFTOP;
D O I
10.1016/j.enbuild.2016.08.054
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper, a performance analysis and economical/environmental assessment of two grid-connected PV systems in Meknes (Morocco) were carried out and their real energy production was reported. The PV system installed in an institutional building, consisted of polycrystalline silicon (Poly-Si) and monocrystalline silicon (Mono-Si) solar cell technologies. The monthly average and annual performance parameters of the PV systems assessed include the total energy generated, final yield, capacity factor and overall system efficiency. It is found that, for the same rated capacity, Poly-Si modules have higher monthly total average final yield than Mono-Si modules. Generally, the installed PV systems in Meknes possess higher performance indicators compared to other regions in the world like Greece, Ireland, India, South-Africa and UAE. This study has also evaluated the levelized cost of electricity (LCOE), Payback time (PB) and annual avoided CO2 emissions for the two systems under investigation. The LCOE found to be in the range 0.073-0.082 $/kW h and PB found to be in the range 11.10-12.69 years for this analysis. Furthermore, it was shown that the installed PV systems have the potential of reducing approximately 5.01 tons of CO2 emission per year. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:188 / 201
页数:14
相关论文
共 50 条
  • [31] Thermodynamic analysis of new concepts for enhancing cooling of PV panels for grid-connected PV systems
    Sopian, Kamaruzzaman
    Alwaeli, Ali H. A.
    Al-Shamani, Ali Najah
    Elbreki, A. M.
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2019, 136 (01) : 147 - 157
  • [32] Empowering the solar energy landscape: The techno-economic analysis of grid-connected PV power plants in Uganda
    Katongole, Daniel Nkwata
    Nyeinga, Karidewa
    Okello, Denis
    Mukiibi, Daniel
    Mubiru, James
    Kisira, Yeeko
    ENERGY FOR SUSTAINABLE DEVELOPMENT, 2024, 82
  • [33] Quantitative analysis of output loss due to restriction for grid-connected PV systems
    Ueda, Yuzuru
    Oozeki, Takashi
    Kurokawa, Kosuke
    Itou, Takamitsu
    Kitamura, Kiyoyuki
    Miyamoto, Yusuke
    Yokota, Masaharu
    Sugihara, Hiroyuki
    ELECTRICAL ENGINEERING IN JAPAN, 2007, 158 (02) : 9 - 19
  • [34] Techno-Economic Analysis of a Hybrid Grid-Connected/PV/Wind System in Pakistan
    Ishaq, Saima
    Naveed, Sadaqat
    Mahmood, Shahid
    Najam-ul-Islam
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2016, 6 (04): : 1318 - 1327
  • [35] Energy and exergy analysis of a 20-MW grid-connected PV plant operating under harsh climatic conditions
    Aoun, Nouar
    CLEAN ENERGY, 2024, 8 (01): : 281 - 296
  • [36] Five-years-long effects of the Italian policies for photovoltaics on the energy demand coverage of grid-connected PV systems installed in urban contexts
    Orioli, Aldo
    Di Gangi, Alessandra
    ENERGY, 2016, 113 : 444 - 460
  • [37] Performance analysis and investigation of a 6 MW grid-connected ground-based PV plant installed in hot desert climate conditions
    Hassane Dahbi
    Nouar Aoun
    Mebrouk Sellam
    International Journal of Energy and Environmental Engineering, 2021, 12 : 577 - 587
  • [38] Electrical Performance Analysis of a 27 kW Grid-Connected PV System with Soiling and Shading in Morelos Mexico
    Sanchez-Perez, P. A.
    Martinez Escobar, D.
    Angel Ruiz, E. O.
    Santos Magdaleno, R.
    Ortega Cruz, Jose
    Sanchez Juarez, A.
    2017 IEEE 44TH PHOTOVOLTAIC SPECIALIST CONFERENCE (PVSC), 2017, : 1990 - 1994
  • [39] Optimising Grid-Connected PV-Battery Systems for Energy Arbitrage and Frequency Containment Reserve
    Dufo-Lopez, Rodolfo
    Lujano-Rojas, Juan M.
    Artal-Sevil, Jesus S.
    Bernal-Agustin, Jose L.
    BATTERIES-BASEL, 2024, 10 (12):
  • [40] Techno-Economic Analysis of Grid-Connected PV Battery Solutions for Holiday Homes in Sweden
    Fiedler, Frank
    Matas, Joaquin Coll
    ENERGIES, 2022, 15 (08)