Safety guarantee technologies of water pressure and water quality: a case study in secondary water supply for high-rise buildings

被引:1
作者
Wang, Dongsheng [1 ,2 ]
Jiang, Fuchun [3 ]
Liu, Hongbin [4 ]
Xiang, Hao [1 ,2 ,5 ]
机构
[1] Nanjing Univ Posts & Telecommun, Sch Automat, Nanjing 210023, Peoples R China
[2] Nanjing Univ Posts & Telecommun, Sch Artificial Intelligence, Nanjing 210023, Peoples R China
[3] Suzhou Tap Co, Suzhou 215002, Peoples R China
[4] Nanjing Forestry Univ, Coinnovat Ctr Efficient Proc & Utilizat Forest Re, Nanjing 210037, Peoples R China
[5] Nanjing Univ Posts & Telecommun, Jiangsu Engn Lab IOT Intelligent Robots, Nanjing 210023, Peoples R China
基金
中国国家自然科学基金;
关键词
Anti-negative pressure facility; Ultraviolet; Sodium hypochlorite; Secondary water supply; UV DISINFECTION; TAP WATER; SYSTEM; COMMUNITY;
D O I
10.5004/dwt.2020.25357
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
With the rapid development of high-rise buildings in the past decades, the secondary water supply (SWS) has drawn great attention. In the traditional SWS of high-rise buildings, water pressure in the main pipeline is not enough to transmit water to high-rise rooftops, and thus water needs to be pumped to the rooftop water tank, then distributed to households with the help of gravity. Meanwhile, the water bio-indices assessment exceeds risk standards for the breeding of microorganisms and pathogens in rooftop water tanks. To avoid this phenomenon, the water pressure is boosted through an anti-negative pressure facility, and then water is distributed to households directly in the practical case of this work. Moreover, secondary disinfection, in which physical (ultraviolet) and chemical (sodium hypochlorite) disinfection techniques are combined, is implemented before the water enters occupants' homes. In this work, safety guarantee technologies of water pressure and water quality are successfully applied in a residential district of Suzhou, China. The results show that the qualified rate of water quality increases from 61% to 100%, and the water pressure fluctuates within 0.03 MPa.
引用
收藏
页码:395 / 407
页数:13
相关论文
共 20 条
[1]   Detection of Acanthamoeba in tap water and contact lens cases using polymerase chain reaction [J].
Boost, Maureen ;
Cho, Pauline ;
Lai, Sindy ;
Sun, Wing-Man .
OPTOMETRY AND VISION SCIENCE, 2008, 85 (07) :526-530
[2]   Five-Year Outbreak of Community- and Hospital-Acquired Mycobacterium porcinum Infections Related to Public Water Supplies [J].
Brown-Elliott, Barbara A. ;
Wallace, Richard J., Jr. ;
Tichindelean, Carmen ;
Sarria, Juan C. ;
McNulty, Steven ;
Vasireddy, Ravikaran ;
Bridge, Linda ;
Mayhall, C. Glenn ;
Turenne, Christine ;
Loeffelholz, Michael .
JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (12) :4231-4238
[3]   Investigating synergism during sequential inactivation of Bacillus subtilis spores with several disinfectants [J].
Cho, Min ;
Kim, Jae-Hong ;
Yoon, Jeyong .
WATER RESEARCH, 2006, 40 (15) :2911-2920
[4]   Ultrasound-induced inactivation of gram-negative and gram-positive bacteria in secondary treated municipal wastewater [J].
Drakopoulou, S. ;
Terzakis, S. ;
Fountoulakis, M. S. ;
Mantzavinos, D. ;
Manios, T. .
ULTRASONICS SONOCHEMISTRY, 2009, 16 (05) :629-634
[5]   Micro hydro power generation from water supply system in high rise buildings using pump as turbines [J].
Du, Jiyun ;
Yang, Hongxing ;
Shen, Zhicheng ;
Chen, Jian .
ENERGY, 2017, 137 :431-440
[6]   The effects of sodium hypochlorite against selected drinking water-isolated bacteria in planktonic and sessile states [J].
Gomes, I. B. ;
Simoes, M. ;
Simoes, L. C. .
SCIENCE OF THE TOTAL ENVIRONMENT, 2016, 565 :40-48
[7]   Comparison of disinfection byproduct formation from chlorine and alternative disinfectants [J].
Hua, Guanghui ;
Reckhow, David A. .
WATER RESEARCH, 2007, 41 (08) :1667-1678
[8]  
Li CH, 2015, ACSR ADV COMPUT, V6, P120
[9]   Influence of secondary water supply systems on microbial community structure and opportunistic pathogen gene markers [J].
Li, Huan ;
Li, Shang ;
Tang, Wei ;
Yang, Yang ;
Zhao, Jianfu ;
Xia, Siqing ;
Zhang, Weixian ;
Wang, Hong .
WATER RESEARCH, 2018, 136 :160-168
[10]   On-Site Determination and Monitoring of Real-Time Fluence Delivery for an Operating UV Reactor Based on a True Fluence Rate Detector [J].
Li, Mengkai ;
Li, Wentao ;
Qjang, Zhimin ;
Blatchley, Ernest R., III .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2017, 51 (14) :8094-8100