Feasibility of electromagnetic navigation bronchoscopy-guided lung resection for pulmonary ground-glass opacity nodules

被引:7
作者
Piao, Zhe [1 ]
Han, Sung Joon [1 ]
Cho, Hyun Jin [1 ]
Kang, Min-Woong [1 ]
机构
[1] Chungnam Natl Univ, Dept Thorac & Cardiovasc Surg, Sch Med, Chungnam Natl Univ Hosp, Munhwa Ro 282, Daejeon 35015, South Korea
关键词
Bronchoscopy; lung; tumor; video-assisted thoracoscopic surgery; localization; ASSISTED THORACOSCOPIC SURGERY; NEEDLE-BIOPSY; LOCALIZATION; TOMOGRAPHY; DIAGNOSIS;
D O I
10.21037/jtd.2020.03.71
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background: Recent advances in imaging modalities and recommended low-dose computed tomography screening programs have made it easier to diagnose early lung cancer. However, the diagnosis of small ground-glass nodules (GGNs) has been problematic due to inappropriate specimen procurement and failure of conventional percutaneous core needle biopsy. Thus, we aimed to evaluate the usefulness of electromagnetic navigation bronchoscopy (ENB)-guided video-assisted lung resection for not only the diagnosis but also treatment of GGNs. Methods: From 2017 to 2019, 110 patients with suspicious lung cancer lesions that were not diagnosed by conventional procedure underwent ENB-guided lung resection. Among 35 cases of GGNs, 33 cases of localization were included in this study (two cup biopsy cases were excluded). We used SuperDimension (TM) for the ENB procedure. After general anesthesia, indigo carmine (0.3-0.5 mL) was injected, and GGNs were resected through video-assisted thoracoscopic surgery. Results: Of the 33 GGNs, 16 were pure (2 adenocarcinomas in situ, 5 minimally invasive adenocarcinomas (MIAs), 3 adenocarcinomas, and 6 benign lesions) and 17 were mixed (1 MIA, 11 adenocarcinomas, and 5 benign lesions). The mean size of all lesions was 11.2 +/- 7.78 mm, mean distance to the pleura was 11.2 +/- 14.2 mm, and mean ENB procedure time was 18.13 +/- 8.88 minutes. Dye localization and surgical resection of GGN were successful in all cases. There was no procedure-related complication. Conclusions: ENB is a feasible and highly accurate localization method for minimally invasive lung resection of small GGNs.
引用
收藏
页码:2467 / 2473
页数:7
相关论文
共 50 条
  • [41] Correlation exploration among CT imaging, pathology and genotype of pulmonary ground-glass opacity
    Cai, Yong
    Chen, Tong
    Zhang, Shiju
    Tan, Min
    Wang, Jiying
    JOURNAL OF CELLULAR AND MOLECULAR MEDICINE, 2023, 27 (14) : 2021 - 2031
  • [42] Preoperative localization of pulmonary nodules by electromagnetic navigation bronchoscopy combined with methylene blue injection
    Wang, Jin
    Huang, Haihua
    Xue, Qian
    Geraci, Travis C.
    Ruan, Zheng
    Ma, Haitao
    JOURNAL OF THORACIC DISEASE, 2024, 16 (09) : 6196 - 6203
  • [43] Radiomics for lung adenocarcinoma manifesting as pure ground-glass nodules: invasive prediction
    Sun, Yingli
    Li, Cheng
    Jin, Luang
    Gao, Pan
    Zhao, Wei
    Ma, Weiling
    Tan, Mingyu
    Wu, Weilan
    Duan, Shaofeng
    Shan, Yuqing
    Li, Ming
    EUROPEAN RADIOLOGY, 2020, 30 (07) : 3650 - 3659
  • [44] Hook-wire localization versus lipiodol localization for patients with pulmonary lesions having ground-glass opacity
    Park, Chul Hwan
    Lee, Sang Min
    Lee, Ji Won
    Hwang, Sung Ho
    Kwon, Woocheol
    Han, Kyunghwa
    Hur, Jin
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2020, 159 (04) : 1571 - +
  • [45] Endobronchial Ultrasound Using Guide Sheath-Guided Transbronchial Lung Biopsy in Ground-Glass Opacity Pulmonary Lesions without Fluoroscopic Guidance
    Park, Jongsoo
    Kim, Changwoon
    Jang, Jong Geol
    Lee, Seok Soo
    Hong, Kyung Soo
    Ahn, June Hong
    CANCERS, 2024, 16 (06)
  • [46] Clinical model to estimate the pretest probability of malignancy in patients with pulmonary focal Ground-glass Opacity
    Jiang, Long
    Situ, Dongrong
    Lin, Yongbin
    Su, Xiaodong
    Zheng, Yan
    Zhang, Yigong
    Long, Hao
    THORACIC CANCER, 2013, 4 (04) : 380 - 384
  • [47] Ground-glass opacity-featured lung adenocarcinoma has no response to chemotherapy
    Zhang, Yang
    Deng, Chaoqiang
    Ma, Xiao
    Gao, Zhendong
    Wang, Shengping
    Zheng, Qiang
    Xia, Guozhan
    Wen, Zhexu
    Han, Han
    Fu, Fangqiu
    Liu, Quan
    Hu, Hong
    Li, Yuan
    Wong, Kwok-Kin
    Chen, Haiquan
    JOURNAL OF CANCER RESEARCH AND CLINICAL ONCOLOGY, 2020, 146 (09) : 2411 - 2417
  • [48] Pulmonary Benign Ground-Glass Nodules: CT Features and Pathological Findings
    Li, Wang-Jia
    Lv, Fa-Jin
    Tan, Yi-Wen
    Fu, Bin-Jie
    Chu, Zhi-Gang
    INTERNATIONAL JOURNAL OF GENERAL MEDICINE, 2021, 14 : 581 - 590
  • [49] Accurate and non-invasive localization of multi-focal ground-glass opacities via electromagnetic navigation bronchoscopy assisting video-assisted thoracoscopic surgery: a single-center study
    Zeng, Chenxi
    Yang, Guang
    Wei, Lu
    Wang, Junhui
    Wang, Xue
    Ye, Fan
    Fu, Xiangning
    Cai, Yixin
    Wang, Jianing
    FRONTIERS IN ONCOLOGY, 2023, 13
  • [50] Cost-effectiveness analysis of electromagnetic navigation bronchoscopy (ENB) for lung nodules
    Ortega, Pilar Rivera
    Rabines Juarez, Angel O.
    Gutierrez, Jessica Gonzalez
    Maceiras, Luis Seijo
    Zulueta, Javier J.
    EUROPEAN RESPIRATORY JOURNAL, 2014, 44