The key points in the pre-analytical procedures of blood and urine samples in metabolomics studies

被引:56
作者
Bi, Hai [1 ]
Guo, Zhengyang [2 ]
Jia, Xiao [2 ,3 ]
Liu, Huiying [4 ]
Ma, Lulin [1 ]
Xue, Lixiang [2 ,3 ,5 ]
机构
[1] Peking Univ, Hosp 3, Dept Urol, 49 Huayuan North Rd, Beijing, Peoples R China
[2] Peking Univ, Hosp 3, Med Res Ctr, 49 Huayuan North Rd, Beijing, Peoples R China
[3] Peking Univ, Hosp 3, Biobank, Beijing, Peoples R China
[4] Peking Univ, Sch Basic Med Sci, Dept Physiol & Pathophysiol, Minist Educ,Key Lab Mol Cardiovasc Sci, Beijing, Peoples R China
[5] Peking Univ, Hosp 3, Dept Radiat Oncol, Beijing, Peoples R China
关键词
Metabolomics; Serum; Plasma; Urine; Preprocessing; CHROMATOGRAPHY-MASS SPECTROMETRY; LIQUID-CHROMATOGRAPHY; HUMAN PLASMA; GAS-CHROMATOGRAPHY; METABONOMIC ANALYSIS; QUALITY ASSESSMENT; HUMAN SERUM; STABILITY; STORAGE; NMR;
D O I
10.1007/s11306-020-01666-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Metabolomics provides measurement of numerous metabolites in human samples, which can be a useful tool in clinical research. Blood and urine are regarded as preferred subjects of study because of their minimally invasive collection and simple preprocessing methods. Adhering to standard operating procedures is an essential factor in ensuring excellent sample quality and reliable results. Aim of review In this review, we summarize the studies about the impacts of various preprocessing factors on metabolomics studies involving clinical blood and urine samples in order to provide guidance for sample collection and preprocessing. Key scientific concepts of review Clinical information is important for sample grouping and data analysis which deserves attention before sample collection. Plasma and serum as well as urine samples are appropriate for metabolomics analysis. Collection tubes, hemolysis, delay at room temperature, and freeze-thaw cycles may affect metabolic profiles of blood samples. Collection time, time between sampling and examination, contamination, normalization strategies, and storage conditions may alter analysis results of urine samples. Taking these collection and preprocessing factors into account, this review provides suggestions of standard sample preprocessing.
引用
收藏
页数:15
相关论文
共 101 条
[1]   Reference intervals for the urinary steroid metabolome: The impact of sex, age, day and night time on human adult steroidogenesis [J].
Ackermann, Daniel ;
Groessl, Michael ;
Pruijm, Menno ;
Ponte, Belen ;
Escher, Genevieve ;
d'Uscio, Claudia H. ;
Guessous, Idris ;
Ehret, Georg ;
Pechere-Bertschi, Antoinette ;
Martin, Pierre-Yves ;
Burnier, Michel ;
Dick, Bernhard ;
Vogt, Bruno ;
Bochud, Murielle ;
Rousson, Valentin ;
Dhayat, Nasser A. .
PLOS ONE, 2019, 14 (03)
[2]   Searching for urine biomarkers of bladder cancer recurrence using a liquid chromatography-mass spectrometry and capillary electrophoresis-mass spectrometry metabolomics approach [J].
Alberice, Juliana Vieira ;
Amaral, Andre F. S. ;
Grace Armitage, Emily ;
Antonio Lorente, Jose ;
Algaba, Ferran ;
Carrilho, Emanuel ;
Marquez, Mirari ;
Garcia, Antonia ;
Malats, Nuria ;
Barbas, Coral .
JOURNAL OF CHROMATOGRAPHY A, 2013, 1318 :163-170
[3]  
Amberg A, 2017, METHODS MOL BIOL, V1641, P229, DOI 10.1007/978-1-4939-7172-5_13
[4]   Metabolomics in early detection and prognosis of acute coronary syndrome [J].
Amiri, Mohammad Pouralijan ;
Khoshkam, Maryam ;
Salek, Reza M. ;
Madadi, Reza ;
Ganji, Ghassem Faghanzadeh ;
Ramazani, Ali .
CLINICA CHIMICA ACTA, 2019, 495 :43-53
[5]   Method Validation for Preparing Serum and Plasma Samples from Human Blood for Downstream Proteomic, Metabolomic, and Circulating Nucleic Acid-Based Applications [J].
Ammerlaan, Wim ;
Trezzi, Jean-Pierre ;
Lescuyer, Pierre ;
Mathay, Conny ;
Hiller, Karsten ;
Betsou, Fay .
BIOPRESERVATION AND BIOBANKING, 2014, 12 (04) :269-280
[6]   Pre-Analytical Sample Quality: Metabolite Ratios as an Intrinsic Marker for Prolonged Room Temperature Exposure of Serum Samples [J].
Anton, Gabriele ;
Wilson, Rory ;
Yu, Zhong-hao ;
Prehn, Cornelia ;
Zukunft, Sven ;
Adamski, Jerzy ;
Heier, Margit ;
Meisinger, Christa ;
Roemisch-Margl, Werner ;
Wang-Sattler, Rui ;
Hveem, Kristian ;
Wolffenbuttel, Bruce ;
Peters, Annette ;
Kastenmueller, Gabi ;
Waldenberger, Melanie .
PLOS ONE, 2015, 10 (03)
[7]   Influences of biofluid sample collection and handling procedures on GC-MS based metabolomic studies [J].
Bando, Kiyoko ;
Kawahara, Rui ;
Kunimatsu, Takeshi ;
Sakai, Jun ;
Kimura, Juki ;
Funabashi, Hitoshi ;
Seki, Takaki ;
Bamba, Takeshi ;
Fukusaki, Eiichiro .
JOURNAL OF BIOSCIENCE AND BIOENGINEERING, 2010, 110 (04) :491-499
[8]   UPLC-ESI-QTOF/MS and multivariate data analysis for blood plasma and serum metabolomics: Effect of experimental artefacts and anticoagulant [J].
Barri, Thaer ;
Dragsted, Lars Ove .
ANALYTICA CHIMICA ACTA, 2013, 768 :118-128
[9]   High-throughput 1H NMR-based metabolic analysis of human serum and urine for large-scale epidemiological studies:: validation study [J].
Barton, Richard H. ;
Nicholson, Jeremy K. ;
Elliott, Paul ;
Holmes, Elaine .
INTERNATIONAL JOURNAL OF EPIDEMIOLOGY, 2008, 37 :31-40
[10]   Standard operating procedures for pre-analytical handling of blood and urine for metabolomic studies and biobanks [J].
Bernini, Patrizia ;
Bertini, Ivano ;
Luchinat, Claudio ;
Nincheri, Paola ;
Staderini, Samuele ;
Turano, Paola .
JOURNAL OF BIOMOLECULAR NMR, 2011, 49 (3-4) :231-243