Use of loop-mediated isothermal amplification of DNA for the rapid detection of Mycobacterium tuberculosis in clinical specimens

被引:37
作者
Neonakis, I. K. [1 ,2 ]
Spandidos, D. A. [3 ]
Petinaki, E. [2 ]
机构
[1] Univ Hosp Herakl, Dept Microbiol, Iraklion 71201, Crete, Greece
[2] Univ Thessaly, Sch Med, Dept Microbiol, Larisa, Greece
[3] Univ Crete, Sch Med, Dept Lab Med, Iraklion, Greece
关键词
SPUTUM SAMPLES; LAMP; MAGNESIUM; DIAGNOSIS; TEMPLATE; SEQUENCE; ASSAY;
D O I
10.1007/s10096-011-1195-0
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Loop-mediated isothermal amplification (LAMP) is a recently developed molecular method that has been successfully implemented in the detection of Mycobacterium tuberculosis in clinical specimens. LAMP has several advantages, such as rapidity, high sensitivity, ease of application and cost-effectiveness. As a result, it is anticipated that its use for the detection of M. tuberculosis is likely to become widespread, especially in low-resource countries. The present review aimed to present this method and all of the available information on its implementation in the detection of M. tuberculosis in clinical specimens.
引用
收藏
页码:937 / 942
页数:6
相关论文
共 25 条
[1]   Polymerase chain reaction for diagnosis of M-tuberculosis: Comparison of simple boiling and a conventional method for DNA extraction [J].
Afghani, B ;
Stutman, HR .
BIOCHEMICAL AND MOLECULAR MEDICINE, 1996, 57 (01) :14-18
[2]   Comparison of six methods of extracting Mycobacterium tuberculosis DNA from processed sputum for testing by quantitative real-time PCR [J].
Aldous, WK ;
Pounder, JI ;
Cloud, JL ;
Woods, GL .
JOURNAL OF CLINICAL MICROBIOLOGY, 2005, 43 (05) :2471-2473
[3]   A novel and more sensitive loop-mediated isothermal amplification assay targeting IS6110 for detection of Mycobacterium tuberculosis complex [J].
Aryan, Ehsan ;
Makvandi, Manoochehr ;
Farajzadeh, Ahmad ;
Huygen, Kris ;
Bifani, Pablo ;
Mousavi, Seyed-Latif ;
Fateh, Abolfazl ;
Jelodar, Abbass ;
Gouya, Mohammad-Mehdi ;
Romano, Marta .
MICROBIOLOGICAL RESEARCH, 2010, 165 (03) :211-220
[4]   Operational feasibility of using loop-mediated isothermal amplification for diagnosis of pulmonary tuberculosis in microscopy centers of developing countries [J].
Boehme, Catharina C. ;
Nabeta, Pamela ;
Henostroza, German ;
Raqib, Rubhana ;
Rahim, Zeaur ;
Gerhardt, Martina ;
Sanga, Erica ;
Hoelscher, Michael ;
Notomi, Tsugunori ;
Hase, Tetsu ;
Perkins, Mark D. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2007, 45 (06) :1936-1940
[5]   NUCLEIC-ACID SEQUENCE-BASED AMPLIFICATION [J].
COMPTON, J .
NATURE, 1991, 350 (6313) :91-92
[6]  
*EIK CHEM CO LTD, 2011, LAMP PRINC
[7]  
*EIK CHEM CO LTD, 2011, LAMP AN
[8]  
*EIK CHEM CO LTD, 2011, PRIMEREXPLORER V4 SO
[9]   Efficacy of loop mediated isothermal amplification (LAMP) assay for the laboratory identification of Mycobacterium tuberculosis isolates in a resource limited setting [J].
Geojith, G. ;
Dhanasekaran, S. ;
Chandran, Salesh P. ;
Kenneth, John .
JOURNAL OF MICROBIOLOGICAL METHODS, 2011, 84 (01) :71-73
[10]   Loop-mediated isothermal amplification for direct detection of Mycobacterium tuberculosis complex, M-avium, and M-intracellulare in sputum samples [J].
Iwamoto, T ;
Sonobe, T ;
Hayashi, K .
JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (06) :2616-2622