Renewable amperometric immunosensor for Schistosoma japonium antibody assay

被引:106
作者
Liu, GD
Wu, ZY
Wang, SP
Shen, GL
Yu, RQ [1 ]
机构
[1] Hunan Univ, Coll Chem & Chem Engn, Inst Chemometr & Sensing Technol, Changsha 410082, Peoples R China
[2] Cent S Univ, Dept Parasitol, Changsha 410078, Peoples R China
关键词
D O I
10.1021/ac0101048
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A renewable amperometric immunosensor has been proposed for the determination of Schistosoma japonium antibody (SjAb) in rabbit serum. A paraffin-graphite-Schistosoma japonium antigen (SjAb) biocomposite, which needs no additional curing, was directly used to construct the immunosensors. The analytical sample containing the desired SjAb was mixed with SjAb labeled with horseradish peroxidase (HRP) to form the incubation solution for the competitive binding assay. Amperometry was used to determine the amount of HRP fixed on the sensor surface, which was related to the content of desired SjAb, Assay conditions were optimized, including the selection of substrate, the loading of SjAg in the biocomposite, the amount of labeled SjAb in the incubation solution, the incubation time, and the temperature. Using o-aminophenol (o-AP) as a substrate, amperometric detection at -200 mV (vs SCE) resulted in a pseudolinear detection range of about 0.36 to 14 mug/mL, with a detection limit of 0.36 mug/mL. Rabbit serum samples with varying infection degrees were analyzed, and the results demonstrated that the concentration that is detectable in this system meets the demands of clinical analyses. A new surface on the immunosensor for use in another competitive assay can be obtained by removing the original one and polishing the surface.
引用
收藏
页码:3219 / 3226
页数:8
相关论文
共 27 条
  • [11] LIU YH, 1991, IMMUNOLOGY IMMUNODIA
  • [12] Development of an ''electrically wired'' amperometric immunosensor for the determination of biotin based on a non-diffusional redox osmium polymer film containing an antibody to the enzyme label horseradish peroxidase
    Lu, B
    Iwuoha, EI
    Smyth, MR
    OKennedy, R
    [J]. ANALYTICA CHIMICA ACTA, 1997, 345 (1-3) : 59 - 66
  • [13] ENZYMATIC IMMUNOASSAY OF ALPHA-FETOPROTEIN, INSULIN AND 17-ALPHA-HYDROXYPROGESTERONE BASED ON CHEMI-LUMINESCENCE IN A FLOW-INJECTION SYSTEM
    MAEDA, M
    TSUJI, A
    [J]. ANALYTICA CHIMICA ACTA, 1985, 167 (JAN) : 241 - 248
  • [14] SMALL-VOLUME VOLTAMMETRIC DETECTION OF 4-AMINOPHENOL WITH INTERDIGITATED ARRAY ELECTRODES AND ITS APPLICATION TO ELECTROCHEMICAL ENZYME-IMMUNOASSAY
    NIWA, O
    XU, Y
    HALSALL, HB
    HEINEMAN, WR
    [J]. ANALYTICAL CHEMISTRY, 1993, 65 (11) : 1559 - 1563
  • [15] Amperometric immunosensors based on rigid conducting immunocomposites
    Santandreu, M
    Cespedes, F
    Alegret, S
    MartinezFabregas, E
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (11) : 2080 - 2085
  • [16] Flow injection immunoanalysis based on a magnetoimmunosensor system
    Solé, S
    Alegret, S
    Céspedes, F
    Fàbregas, E
    Díez-Caballero, T
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (08) : 1462 - 1467
  • [17] 3,3′,5,5′-tetramethylbenzidine as electrochemical substrate for horseradish peroxidase based enzyme immunoassays.: A comparative study
    Volpe, G
    Compagnone, D
    Draisci, R
    Palleschi, G
    [J]. ANALYST, 1998, 123 (06) : 1303 - 1307
  • [18] Sol-gel-derived thick-film amperometric immunosensors
    Wang, J
    Pamidi, PVA
    Rogers, KR
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (06) : 1171 - 1175
  • [19] Wang J, 1999, ANAL CHEM, V71, p328R
  • [20] Thick film electrochemical immunosensor based on stripping potentiometric detection of a metal ion label
    Wang, J
    Tian, BM
    Rogers, KR
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (09) : 1682 - 1685